EEWORLDEEWORLDEEWORLD

Part Number

Search

3C40UM

Description
Circuit Breakers 40A MCB CCHAR 3 PL 480Y/277VAC UL508
CategoryCircuit protection    Circuit protection   
File Size548KB,1 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Parametric View All

3C40UM Online Shopping

Suppliers Part Number Price MOQ In stock  
3C40UM - - View Buy Now

3C40UM Overview

Circuit Breakers 40A MCB CCHAR 3 PL 480Y/277VAC UL508

3C40UM Parametric

Parameter NameAttribute value
MakerAltech
Reach Compliance Codeunknown
Circuit protection typeTHERMAL MAGNETIC
Base Number Matches1
V-EA-Series - UL508 Manual Motor Controller -
3 pole C-Trip
UL508 Listed
E137938
Standard Pack:
6
Weight:
0.3A - 32A
1.8kg (3.97 lb.)
40A - 63A
1.98kg (4.37 lb.)
Three Pole
35 mm
(1.38 in.)
93.3 mm
(3.67 in.)
74.7 mm
(2.94 in.)
52.5 mm
(2.07 in.)
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
Type/
Cat. No.
3C03UM
3C05UM
3C075UM
NA
3C1UM
3C1.6UM
3C2UM
3C2.5UM
3C3UM
3C3.5UM
3C4UM
3C5UM
3C6UM
3C8UM
3C10UM
NA
3C13UM
3C15UM
3C16UM
3C20UM
3C25UM
3C30UM
3C32UM
3C40UM
3C50UM
3C60UM
3C63UM
Approvals
V-EA-C Trip
0.3A Through 10A Rated Current
1.13-1.45xI
N
60
40
Minutes
10
4
1
Thermal Overload
“Must Trip” < 1 hr = 145% RC
“Must Not Trip” > 1 hr = 113% RC
Tripping time t
10
4
1
0.4
10
-1
4x10
-2
Seconds
10
-2
4x10
-3
10
-3
1
2
3 4
5
6 8
10
20
40
100
Multiple of Rated Current
V-EA-C Trip
13A Through 63A Rated Current
1.13-1.45xI
N
60
40
Minutes
10
4
1
Thermal Overload
“Must Trip” < 1 hr = 145% RC
“Must Not Trip” > 1 hr = 113% RC
Tripping time t
10
4
1
0.4
10
-1
4x10
-2
Voltage Rating
Short Circuit Withstand Rating
(UL/CSA - Ratings)
Group Short Circuit Withstand Rating
(UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings)
Calibration Temperature
Operating Temperature
Storage Temperature
Terminal Size Acceptability
Terminal Torque
Terminal Protection Degree
480Y/277VAC
0.3-25A: 1 pole - 42VDC; 2 Pole - 80VDC
30-60A: 1 pole - 24VDC; 2 Pole - 60VDC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 13-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
40°C (104°F)
-25°C to 55°C (-13°F to 131°F)
-40°C to 70°C (-40°F to 158°F)
Top: 18-3 AWG; Bottom: 18-2 AWG (Line/Load reversible)
20 lb.in.
IP20
Seconds
10
-2
4x10
-3
10
-3
1
2
3 4
5
6 8
10
20
40
100
Multiple of Rated Current
Standard Dual
Connection Terminal
All parts are ring tongue compatible.
short circuit Withstand ratings for v-ea manual motor controller
Trip
Curve
all
all
all
all
Backup
Protection
Amp Range
0.3 - 10A
12 - 30/32A
40 - 50A
60 / 63A
UL-Listed
RK5-Fuse
up to 10kA
4xRC*
min 15A, max 70A
4xRC*
max 125A
4xRC*
max 200A
4xRC*
max 250A
UL-Listed
MCCB
up to 10kA
4xRC*
min 15A, max 70A
4xRC*
max 125A
4xRC*
max 200A
4xRC*
max 250A
No BCP
Required
up to:
10kA
5kA
5kA
5kA
Ring
tongue
Box
clamp
*up to nearest rated current
Zigbee networking and data transmission issues
I want to implement my own application based on the simpleApp example. I use two zigbee modules (Bochuang CC2430), one as a coordinator and the other as a terminal device. I connect a light sensor to ...
itman20 RF/Wirelessly
Can the 18650 lithium battery safety valve prevent explosion?
What is a lithium battery safety valve? After 30 years of development, the 18650 battery manufacturing process has become very mature. In addition to greatly improving performance, its safety is also ...
qwqwqw2088 Analogue and Mixed Signal
EEWORLD University - Basic knowledge of linear regulators in the introductory course on power supply
Power Supply Introductory Course: Basic Knowledge of Linear Regulators : https://training.eeworld.com.cn/course/289????? In this course, we will introduce the various types of linear regulators (LDOs)...
chenyy Power technology
About the power supply of integrated operational amplifiers
Can the negative power supply of an integrated operational amplifier be directly grounded? Does it have any effect on the circuit? ? ? ?...
woshihuxiaolind Analog electronics
Does Vxworks support the POWERPC series dual-core P2020?
[i=s] This post was last edited by tsinghua-gmm on 2015-8-11 11:30 [/i] I am a newbie, and I would like to ask the experts to tell me whether Vxworks supports the dual-core P2020 of POWERPC series? If...
tsinghua-gmm NXP MCU
How to use the voice control module to control the microcontroller switch (or execute part of the program)?
[font=宋体] I just came into contact with single-chip microcomputers, and I want to use sensors to control single-chip microcomputers (such as voice control modules, vibration module switches). These se...
冶金 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 356  849  496  1377  2159  8  18  10  28  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号