BK/GMC-3.5-R

Description
Cartridge Fuses 3.5A 125VAC TD GMC Series
CategoryCircuit protection    Circuit protection   
File Size380KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK/GMC-3.5-R Overview

Cartridge Fuses 3.5A 125VAC TD GMC Series

BK/GMC-3.5-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Fusing characteristicsMEDIUM TIME DELAY
body height20 mm
Body length or diameter5.2 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal25 J
Manufacturer's serial numberGMC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size5.2mm x 20mm
Rated breaking capacity10000 A
Rated current3.5 A
Rated voltage (AC)125 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
Technical Data
4395
Effective
February
2018
Supersedes
May
2017
HALOGEN
GMC
HF
Pb
FREE
5 mm
x
20 mm Medium time-delay
glass tube fuses
Agency information
UL Listed, Guide JDYX, File E19180, 63mA-6.3A
UL Recognized Card: (7A-10A) Guide JDYX2, File E19180
CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
MITI Approval, 1A-10A
KC-Mark: Certificate SU05011-4001 (63mA~250mA);
SU05011-4002 (300mA~800mA); SU05011-4003 (1A~3.15A);
SU05011-4004 (3.5A~6.3A)
Ordering
Product features
Medium time-delay, low breaking capacity
Available with optional axial leads
5 mm x 20 mm physical size
Glass tube, nickel-plated brass endcap construction
Designed to UL/CSA 248-14
Specify packaging code prefix, product number and option
code suffix
Rated Current
63mA - 10A
Electrical Characteristics
% of Amp Rating
Opening Time
100%
None
135%
60 minutes maximum
200%
2 minutes maximum
Typical
Pre-Arc I
2
t
AC
0.0027
0.0050
0.0094
0.014
0.022
0.022
0.032
0.046
0.081
0.081
0.18
0.41
0.60
0.66
0.85
0.85
0.85
1.8
3.4
5.4
5.8
8.9
13
19
23
25
36
58
88
110
150
200
300
Maximum
Voltage
Drop
(mV)
1400
1400
1200
1000
800
730
650
490
580
480
510
370
360
360
340
320
290
250
200
190
160
130
130
130
130
130
120
120
120
120
120
110
110
Product
Number
GMC-63-R
GMC-80-R
GMC-100-R
GMC-125-R
GMC-150-R
GMC-160-R
GMC-200-R
GMC-250-R
GMC-300-R
GMC-315-R
GMC-400-R
GMC-500-R
GMC-600-R
GMC-630-R
GMC-700-R
GMC-750-R
GMC-800-R
GMC-1-R
GMC-1.25-R
GMC-1.5-R
GMC-1.6-R
GMC-2-R
GMC-2.5-R
GMC-3-R
GMC-3.15-R
GMC-3.5-R
GMC-4-R
GMC-5-R
GMC-6-R
GMC-6.3-R
GMC-7-R
GMC-8-R
GMC-10-R
Voltage
Rating
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
125
125
125
125
125
125
125
125
Interrupting Rating (Amps)*
250Vac
125Vac
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
10,000
-
200
-
200
-
200
Typical DC Cold
Resistance
(Ω)**
10.350
-
4.775
3.400
2.555
2.295
1.395
0.965
0.838
0.685
0.615
0.335
0.282
0.246
0.213
0.213
0.180
0.156
0.098
0.076
0.067
0.043
0.035
0.026
0.025
0.022
0.019
0.014
0.013
0.012
0.012
0.009
0.007
* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of rated current)
2
Typical Pre-Archint (I t was measured at listed interrupting rating and rated voltage)
g
2
Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)
MSP430 SPI master-slave communication problem
[color=#000]Now, two 430 MCUs are used for SPI communication. It is hoped that the slave will send data and the host will receive data and return. After writing the program, it is found that the host ...
luooove Microcontroller MCU
Synplify Tool User Guide.pdf
Synplify Tool User Guide.pdf...
zxopenljx FPGA/CPLD
Is it necessary to set the layer thickness in the stack management when designing a 4-layer PCB in AltiumDesigner?
I have never drawn a 4-layer PCB before. I saw that the thickness of each layer can be set in the stack management. When sending it to the manufacturer for production, I can't just tell them whether i...
littleshrimp PCB Design
at+cipstart="tcp","210.153.49.2","80" ERROR What's going on?
AT+CGATT=1 OK AT+CGDCONT=1,"IP","CMWAP" OK AT+CGACT=1,1 OK AT+CGPADDR=1 +CGPADDR: 1,"10.177.14.204"OK AT+CGDATA=1 CONNECT 115200 ~ }#?}!}!} }6}!}$}%軁"}&} } } } }'}"}(}"}#}$?&磣~ }#?}!}!} }6}!}$}%軁"}&} ...
citylove Embedded System
Why is the output not 7.5V?
[i=s] This post was last edited by paulhyde on 2014-9-15 09:33 [/i] As shown in the picture: 7805 outputs 5V, TL431 should output 2.5v, and the final output should be 5+2.5=7.5v. However, the multimet...
江汉大学南瓜 Electronics Design Contest
Please ignore the points. Please ignore the points.
Just for points, please ignore...
bds489550896 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2875  926  1676  1572  1549  58  19  34  32  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号