TR-11CX632.2A

Description
Circuit Breakers CIRCUIT BREAKER FOR EQUIPMENT,
CategoryCircuit protection   
File Size3MB,6 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet Parametric View All

TR-11CX632.2A Overview

Circuit Breakers CIRCUIT BREAKER FOR EQUIPMENT,

TR-11CX632.2A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerAltech
Product CategoryCircuit Breakers
ProductCircuit Breakers
TypeSupplementary Protector
Current Rating2.2 A
Voltage Rating AC240 VAC
Voltage Rating DC32 VDC
Actuator TypePushbutton
Termination StyleQuick Connect
Voltage Rating240 VAC, 32 VDC
Mounting StyleSnap In
Factory Pack Quantity10
UL 489
UL 508
TR11 Series
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Applications:
Protection of Control Transformers, UPS, Power
strips, Solenoids etc., against damage due to
overload conditions.
Current Rating (A)
Standard Current Rating (A)
0.1 - 16A
0.1, 0.25, 0.5, 0.9, 1.0, 1.2, 1.5, 1.8, 2.0, 2.2, 2.5,
2.7, 3.0, 3.3, 4.0, 5.0, 6.0, 6.5, 7.0, 8.0, 9.0,
10.0, 12.0, 15.0, 16.0
240V AC, 50/60Hz,
50V DC / 24V DC (VDE)
> 100 M ohms.
(As per EN 60934)
E209569
up to 12 Amps
Operating Characteristic
(min) 60
30
20
10
5
1
(S) 50
20
10
5
2
1
Trip time
0.5
0.2
0.1
1.05 1.32
2
3
4 5
8 10
Rated Voltage
Initial insulation resistance (500V DC)
Dielectric strength
1.5 KV for One minute.
(As per EN 60934)
6 I
n
- AC up to 9.0A
(As per EN 60934)
4 I
n
- DC up to 12.0A
60A AC/DC Max. - from 10.0A to 12.0A
8x I
n
AC/DC for <6.0A
60A AC/DC MAX. for > 6.0A
1 - 2 Watts
Maximum 60°C Ambient
1000 Cycles
1000 Amps PC 1,240V AC, 24V DC, Ref.: EN60934
SC: 1KA, C1, 240V AC 50V DC
Ref.: CSA22.2 No.235-04, UL-1077
TC 2Ref.: CSA22.2 No. 235-04
OL0 240V AC, 50V DC, Ref.: CSA22.2 No. 235-04
General Industrial Ref.: CSA22.2 No. 235-04
Thermal ‘TO’ Trip Free
Reset Type ‘R’
CSA 22.2 No. 235-04, UL-1077, EN 60934
aprox. 11g
0.1 - 16.0A
240V AC 50V DC
0.5 - 12.0A
240V AC 24V DC
UL 1077
Overload Switching Capacity
Maximum Breaking Capacity
Power Loss
Operating Temperature
Operational Life at 2xI
n
Rated Conditional Short Circuit
Current Capacity I
nc1
(PC1)
Ref.: EN60934
Tripping Current Code TC
Overload Rating
Application Type
Method of Tripping
Type of Actuation
Application Standards
Weight
Approvals
UL 1077
Equipment Breakers
Multiple of Rated Current
Rated current
Ambient
Temperature
ORDERING INSTRUCTIONS
Earth Leakage
Circuit Breakers
PRODUCT
TYPE
CURRENT RATING
0.1 TO 16.0A
MOUNTING NUT
<6A
>6A
23°C
Time Current Characteristics:
The standard characteristic is valid for
ambient temperatures of +23°C. If the
device is to be used in an ambient
temperature other than +23°C,
allowances must be made when selecting
the current rating according to the
following guidelines:
Ambient temp.°C
-20
-5
0
+10 +20 +30 +40 +50 +60
1
1.05 1.12 1.2 1.3
1.8A
40°C
1.12
1.8 x 1.12 = 2.016
2.0A
Correction Factor
Example:
0.8 0.88 0.9 0.96
*
ANNEX
Normal Continuous Current
Ambient Temperature
Correction Factor
Recommended Current Rating
Select the nearest
*
Terminal configuration option X is available up to 12A; special order only. Consult Altech for ordering.
Note: TR11-C Series stocked; contact Altech for availability.
80
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • P 908.806-9400 • F 908.806.9490 • www.altechcorp.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2829  2301  2202  1876  976  57  47  45  38  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号