THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
80D
www.vishay.com
Vishay Sprague
NOMINAL CASE SIZE
DxL
1.18 x 1.38 (30.0 x 35.0)
1.38 x 1.38 (35.0 x 35.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.57 (25.0 x 40.0)
1.18 x 1.18 (30.0 x 30.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.97 (30.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
1.38 x 1.18 (35.0 x 30.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
1.18 x 0.984 (30.0 x 25.0)
1.18 x 1.38 (30.0 x 35.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.57 (30.0 x 40.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
0.984 x 1.18 (25.0 x 30.0)
0.984 x 1.57 (25.0 x 40.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
MAX. ESR (m)
MAX. RIPPLE AT +85 °C (A)
10 kHz TO 40 kHz
4.2
7.2
7.2
10.0
4.9
3.6
4.9
6.1
3.8
3.9
6.6
6.4
10.0
3.5
3.7
5.9
6.2
6.2
3.2
3.6
4.9
5.7
4.7
7.4
6.6
6.6
3.2
3.8
5.2
6.3
7.0
7.4
ELECTRICAL DATA AND ORDERING INFORMATION
CAPACITANCE (μF)
PART NUMBER
120 Hz 10 kHz TO 40 kHz 120 Hz
60.0
33.0
33.0
20.0
57.0
79.0
51.0
40.0
82.0
72.0
40.0
36.0
21.0
139.0
111.0
68.0
55.0
50.0
660.0
460.0
278.0
220.0
248.0
130.0
144.0
141.0
720.0
541.0
343.0
263.0
185.0
191.0
51.0
27.0
27.0
17.0
42.0
63.0
41.0
32.0
55.0
54.0
28.0
28.0
15.0
85.0
74.0
42.0
37.0
37.0
375.0
272.0
165.0
131.0
127.0
82.0
81.0
75.0
377.0
284.0
182.0
140.0
101.0
81.0
3.8
6.2
6.2
8.8
3.9
3.1
4.3
5.3
2.8
3.2
5.0
5.4
8.3
2.2
2.7
3.9
4.7
5.2
1.3
1.7
2.4
2.8
2.1
4.3
3.4
3.4
1.1
1.4
2.0
2.5
3.2
4.0
35 WV
DC
AT +85 °C, SURGE = 44 V
6800.0
10 000.0
12 000.0
15 000.0
3300.0
3300.0
4700.0
6800.0
1500.0
2200.0
3300.0
4700.0
6800.0
680.0
1000.0
1500.0
2200.0
3300.0
150.0
220.0
330.0
470.0
680.0
820.0
1000.0
1200.0
100.0
150.0
220.0
330.0
470.0
680.0
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
80D682P035KC2DE3
80D103P035MC2DE3
80D123P035KE2DE3
80D153P035ME2DE3
80D332P050JD2DE3
80D332P050KB2DE3
80D472P050KD2DE3
80D682P050KE2DE3
80D152P063JB2DE3
80D222P063KB2DE3
80D332P063MB2DE3
80D472P063KE2DE3
80D682P063ME2DE3
80D681P100JB2DE3
80D102P100KB2DE3
80D152P100JE2DE3
80D222P100KE2DE3
80D332P100ME2DE3
80D151P200JA2DE3
80D221P200KA2DE3
80D331P200KC2DE3
80D471P200KD2DE3
80D681P200KD2DE3
80D821P200ME2DE3
80D102P200ME2DE3
80D122P200ME2DE3
80D101P250JA2DE3
80D151P250JB2DE3
80D221P250JD2DE3
80D331P250JE2DE3
80D471P250KE2DE3
80D681P250ME2DE3
50 WV
DC
AT +85 °C, SURGE = 63 V
63 WV
DC
AT +85 °C, SURGE = 79 V
100 WV
DC
AT +85 °C, SURGE = 125 V
200 WV
DC
AT +85 °C, SURGE = 250 V
250 WV
DC
AT +85 °C, SURGE = 300 V
Revision: 20-Jul-16
Document Number: 42060
3
For technical questions, contact:
aluminumcaps4@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
The selection principle proposed is to separate the motor characteristics from the load characteristics and express them in a graphical form. This representation method makes it easier to check the fe...
The carrier amplitude of the AM wave is 7V, the frequency is 20kHz, the modulation wave signal frequency is 400Hz, the amplitude? I don’t know so I don’t know the modulation degree. . . ....
I am a newbie. After importing the 3.3 example into CCS5.3, a warning appeared after debugging (as shown in the picture). Can someone please give me some advice on how to solve this problem?...
Ten netizens will be selected for the annual selection of the top ten netizens, eight of whom will be selected by voting, one by the moderator, and one by the administrator. Please vote for one of the...
[color=#333333]How do you understand -48V power supply? It is obviously -48V, but many communication devices use 48V power supply. How do you understand it? [/color]...
In June 2014, the Ministry of Industry and Information Technology issued 4G FD-LTE licenses to China Unicom and China Telecom. Together with the 4G TD-LTE licenses issued to China Mobile, China Uni...[Details]
1. Multi-channel DAC technology bottleneck
Currently,
the development of multi-channel DAC technology focuses on two core challenges.
First, industrial applications urgently ...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Analog Devices held a third-quarter fiscal 2025 earnings conference call. Vincent T. Roche, CEO and Chairman of the Board, and Richard C. Puccio, Executive Vice President and Chief Financial Office...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]
I believe everyone has heard of memory. If your computer is slow, your experts may recommend upgrading it to a larger capacity. But what exactly is computer memory used for? Why does memory capacit...[Details]
While aberration theory is a vast subject, a basic understanding of some fundamental concepts can make it easier to understand: spherical aberration, astigmatism, field curvature, and chromatic abe...[Details]
Perhaps due to the stereotypes surrounding electronic products, many owners of pure electric vehicles have questions about charging. What's the correct way to charge? How can charging slow down bat...[Details]
01 Introduction
The SINAMICS V20 inverter controls three-phase AC asynchronous motors. Depending on the size (frame sizes FSA to FSD), the power range of the three-phase AC 400V inverter cover...[Details]
On August 18, John Krafcik, former CEO of Google's Waymo, recently questioned Tesla's Robotaxi service. He said: "Please notify me when Tesla launches Robotaxi. I'm still waiting. If there are empl...[Details]
On August 14, Chinese researchers broke through the bottleneck of energy density and application performance of existing traditional lithium-ion batteries and developed soft-pack batteries with an ...[Details]
After suspending its autonomous driving business for a period of time, General Motors chose to return to the track. In the past, GM hoped that its Cruise would leap into L4 autonomous driving - no ...[Details]
Under the guidance of the "dual carbon" goals, vehicle-to-grid interaction (V2G), an innovative model that achieves deep integration of new energy vehicles and power grids, is steadily moving from ...[Details]
/*This code has been verified on the 51 MCU. The 51 is an 8-bit MCU. char occupies 1 byte and long occupies 4 bytes*/
int main(void)
{
unsigned long iii;
...[Details]
The penetration of high-end intelligent driving is accelerating, and the wire-controlled chassis has emerged.
The demand for intelligent vehicles is driving the continuous upgrade of...[Details]