EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T110-K0CU-60A

Description
Circuit Breakers 489, 1P, DM, 240VAC/60VDC, C, 60A
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

4230-T110-K0CU-60A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T110-K0CU-60A - - View Buy Now

4230-T110-K0CU-60A Overview

Circuit Breakers 489, 1P, DM, 240VAC/60VDC, C, 60A

4230-T110-K0CU-60A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
protel99se tutorial
Looking for protel99se tutorials and exercises...
zengpeipei PCB Design
Does PIC16F73 have only one AD result memory?
Only ADRES? 877 seems to have ADRESL, ADRESH?...
atkartech339 Microchip MCU
How to get the boot code of lm3sxxx series chips when building a project under IAR
As the title says, I want to use IAR EWARM to write LM3S code, but I don't know how to get the startup code file? It is automatically generated in keil. I hope someone who knows can tell me, thank you...
Fortware Microcontroller MCU
Application of EthernetPOWERLINK in machine control field
Application of EthernetPOWERLINK in machine control field...
EPACCN Industrial Control Electronics
A8+KSZ9021 network card driver problem
ping: sendto: No buffer space available ping: sendto: No buffer space available ping: sendto: No buffer space available 192.168.232.26: icmp_seq=28 ttl=64 time=0 ms 192.168.232.26: icmp_seq=29 ttl=64 ...
sundhhy DSP and ARM Processors
When I enter TCPMP, the waiting icon appears only for the first time. How can I make it appear every time?
When entering TCPMP, the waiting icon only appears for the first time. How can I make it appear every time? When exiting TCPMP, the process has been closed. Thank you!...
lxchina Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2167  71  2628  292  2492  44  2  53  6  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号