EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-T110-K1M2-ALH0-50A

Description
Circuit Breakers 1077, 1p, DIN, 240/415VAC Med Delay, 50A
CategoryCircuit protection   
File Size402KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

8340-T110-K1M2-ALH0-50A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-T110-K1M2-ALH0-50A - - View Buy Now

8340-T110-K1M2-ALH0-50A Overview

Circuit Breakers 1077, 1p, DIN, 240/415VAC Med Delay, 50A

8340-T110-K1M2-ALH0-50A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description
Single, two and three pole magnetic and hydraulic-magnetic circuit
breakers with trip-free mechanism and toggle actuation. A choice of
fast magnetic only or hydraulically delayed switching characteristics
(S-type MO or HM CBE to EN 60934) ensures suitability for a wide
range of applications. Featuring a combi-foot design for symmetric rail
mounting. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Power supplies, control equipment, communication systems, EDP
systems.
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
single pole
8340-T...
1
three pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415V; AC 240V (50/60Hz); DC 80V
(higher DC voltages to special order)
Current rating range
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V
Typical life
3 AC 415 V AC 240 V:
0.02...30 A 6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
WDC 80 V: 0.02...25 A 6,000 operations at 1 x I
N
, inductive
0.02...30 A 10,000 operations at 1 x I
N
, resistive
40 + 50 A 6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
I
N
0.02...20 A
25...30 A
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
DC:
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
operating area IP40
terminal area IP20
10 g at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
100 g (11 ms) at 0.8 x I
N
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 98 g per pole
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
1708
www.e-t-a.de
1
Single lithium battery boost 12V1.5A, 18W
FP6296 is a current mode DC-DC boost converter with pulse width modulation (PWM) and built-in 0.015Ω, 10A, 14V MOSFET, capable of high power conversion efficiency, fewer peripheral components and spac...
eward250 Power technology
The ground wire of the voltage follower has high-frequency harmonics
I would like to ask you, the ground line of my voltage follower has a sine harmonic of about 200MHz, and the voltage amplitude is 1V, what's going on? ? The input signal is a 40MHz sine wave through t...
jys031006 Analog electronics
TD-SCDMA: Breaking down bottlenecks in the industry chain
Review of TD-SCDMA Important Events in 2006The year 2006, which is about to pass, is of great significance to TD-SCDMA. In this peaceful yet turbulent year, we have witnessed the breakthroughs made by...
changjiang RF/Wirelessly
Ask a few questions about wince burning
I customized the wince6.0 system in PB and generated the nk.bin nk.nb0 files. When generating the image, I did not add the bootloader and oal in the BSP to compile. I want to burn nk.bin to the develo...
xiaoyuanhb09 Embedded System
Talking about IPC boot of F28M35
After the chip is powered on, first power on and run the BOOTROM in the M3 core--FLASH startup jumps to FLASH--run the program to initialize the clock SysCtlClockConfigSet--initialize RAM to set the v...
hlx3012 Microcontroller MCU
What software can I use to download programs into the AVR microcontroller?
What software can I use to download programs to the AVR microcontroller? I need advice from an expert. I have tried several software but none of them work!...
785180572 Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 979  2179  1569  2664  235  20  44  32  54  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号