EEWORLDEEWORLDEEWORLD

Part Number

Search

2210-T230-K0T1-H231-8A

Description
Circuit Breakers 1077, 3P, DM, 480VAC/65VDC,T1, 1NC AUX, 8A
CategoryCircuit protection   
File Size319KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

2210-T230-K0T1-H231-8A Online Shopping

Suppliers Part Number Price MOQ In stock  
2210-T230-K0T1-H231-8A - - View Buy Now

2210-T230-K0T1-H231-8A Overview

Circuit Breakers 1077, 3P, DM, 480VAC/65VDC,T1, 1NC AUX, 8A

2210-T230-K0T1-H231-8A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Thermal-Magnetic Circuit Breaker 2210-T2...
Description
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of an overload on one pole, even if the
actuator is held in the ON position. This CBE can be supplied in current
ratings up to 32 A with a choice of characteristic curves. All screw
terminals are recessed for safety. Approved to CBE standard EN 60934
(IEC 60934).
Typical applications
Process control equipment, robotics, machine tool control,
communications systems, instrumentation.
1-pole
2210-T2..
1
3-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V
(UL: AC 277/480 V; DC 65 V)
Current rating range
0.1...32 A for curves M1, T1
0.1...16 A for curves F1, F2
Auxiliary circuit
1 A, AC 240 V / DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
3 AC 433 V; AC 250 V: 0.1...25 A
10,000 operations at 1 x I
N
, inductive
DC 65 V:
0.1...32 A
10,000 operations at 1 x I
N
, inductive
3 AC 433 V; AC 250 V: 32 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 3,000 V
pole/pole
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A
400 A
6...32 A
800 A
curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V)
Interrupting capacity (UL 1077)
I
N
0.1...16 A
20...25 A
Preferred types
Preferred types
1-pole
2210-T210-K0M1-H121-
2-pole
2210-T220-K0M1-H221-
Standard current ratings (A)
0.5 1
x
x
2
x
3
x
4
x
5
x
6
x
8 10 16 20
x
x
x
x
0.5 1
2
x
3
4
x
5
6
x
8 10 16 20
x
x
x
Ordering information
Type No.
2210
single and multipole thermal-magnetic circuit breaker
Mounting
T
rail mounting
Actuator design
2
toggle
Number of poles
1
single pole protected
2
2-pole protected
3
3-pole protected
Accessories
0
without accessories
Terminal design (main contacts)
K0
screw terminals
Characteristic curve
F1
fast acting: therm.1.01-1.4xI
N
;
magn.2-4xI
N
DC (DC only)
F2
fast acting: therm.1.01-1.4xI
N
;
magn.3,5-6,5xI
N
AC/4,5-8,5xI
N
DC
M1
standard delay: therm. 1.01-1.4xI
N
;
magn. 6-12xI
N
AC, 7.8-15.6xI
N
DC
T1
delayed: therm. 1.01-1.4xI
N
; magn. 10-20xI
N
AC
Auxiliary contact design
H
without intermediate position
Auxiliary contacts
1
with auxiliary contacts
2
auxiliary contacts on pole 1 only
(multipole devices)
Auxiliary contact function (see diagrams)
2
1 N/O contact
3
1 N/C contact
Auxiliary contact - terminal design
1
screw terminals
Current ratings
0.1...32 A
2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A
ordering example
AC 277 V
1-pole
AC 277/480 V
2-/3-pole
DC 65 V
Degree of protection
(IEC 60529/DIN 40050)
Vibration curves F1, F2:
curves M1, T1:
5,000 A
5,000 A
2,000 A
2,000 A
2,000 A
2,000 A
operating area IP30
terminal area IP20
3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 60 g per pole
1812
www.e-t-a.de
1
I would like to ask everyone, how should software engineers in electrical companies learn?
Why can't I find this online?...
而为人温柔 Industrial Control Electronics
VxWorks and Simulink real-time simulation, how to load the model .lo? (urgent)
After rtw is compiled, a .lo model is generated. How do you load the model .lo? When using loadModule to load, it always reports undefined symbol types... There are references that point out that the ...
andyye1630 Real-time operating system RTOS
CE5.0 input panel issues
1. How can I make the input panel immovable in CE5.0 application? 2. How can I show or hide the input panel and move the application window so that it is not blocked? 3. How can I add an input switch ...
wangzicc Embedded System
【TI's First Low Power Design Competition】 slotg(04): FRAM power-off data memory
This is a basic exercise for the MSP430FR5969 LaunchPad. It is programmed using the DriverLib library in CCS6. The board we designed needs to be powered off in many applications. For example, the mach...
slotg Microcontroller MCU
Have you ever encountered problems with function return classes in embedded programming?
I don't know since when, I have a subconscious understanding of the function return value: "0" means success, non-"0" means failure.  Let me tell you a story first, which is a small episode during the...
fish001 Microcontroller MCU
Follow me to get started with the Renesas Electronics MCU Kit from scratch-----(1) Install the environment and download the LED DEMO
[i=s]This post was last edited by ctqvsly on 2014-8-22 19:26[/i] [b][size=3]1. Install the development environment:[/size][/b][b][size=3]It is recommended that you use the latest version of CubeSuite+...
ctqvsly Renesas Electronics MCUs

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1913  1922  1505  1595  497  39  31  33  10  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号