Off-line systems with auto-ranging or PFC front ends, industrial and process control,
distributed power, medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High-frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V375B12T300BL2
375B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= –10 to +100 –20 to +125
C
= –20 to +100 –40 to +125
T
= –40 to +100 –40 to +125
H
= –40 to +100 –55 to +125
M
= –55 to +100 –65 to +125
B
Output Power
P
OUT
100W
100W, 150W
150W, 200W
200W
200W, 300W
200W, 300W
200W, 300W
200W, 300W
200W, 300W
200W, 300W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
375V Mini Family
Page 1 of 14
Rev 9.9
05/2018
375V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn–on
Undervoltage turn–off
Overvoltage turn–off/on
Disabled input current
204.7
429.2
242.5
212.2
446.3
467.5
1.1
Min
250
Typ
375
Max
425
500
247.5
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 3.1
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.1
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
375V Mini Family
Page 2 of 14
Rev 9.9
05/2018
3075V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
[89.3]
3.5
[99.6]
100
3000
1500
500
10
3.5
[100.3]
3.9
[110.6]
115
cURus, cTÜVus, CE
3.9
[111.3]
4.3
[121.6]
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
[grams]
ounces
[grams]
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
375V Mini Family
Page 3 of 14
Rev 9.9
05/2018
375V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS
2
V
OUT
, 100W (e.g. S375B2C100BL, V375B2C100BL)
Parameter
Efficiency
S375B2C100BL (enhanced efficiency)
V375B2C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
79.0
73.6
2.7
Typ
83.0
74.6
100
2.8
5.1
±0.02
57.5
57.5
Max
Unit
%
125
2.9
5.3
±0.3
50
70
70
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
3.3
V
OUT
, 150W (e.g. S375B3V3C150BL, V375B3V3C150BL)
Parameter
Efficiency
S375B3V3C150BL (enhanced efficiency)
V375B3V3C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
79.0
4.14
Typ
85.0
80.3
100
4.3
5.1
±0.02
53.8
54.5
Max
Unit
%
125
4.46
7.7
±0.2
45.45
63.7
63.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
45.5
31.8
3.3
V
OUT
, 100W (e.g. S375B3V3C100BL, V375B3V3C100BL)
Parameter
Efficiency
S375B3V3C100BL (enhanced efficiency)
V375B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
79.0
4.14
Typ
85.0
80.1
108
4.3
3.8
±0.02
34.8
34.8
Max
Unit
%
135
4.46
5.5
±0.2
30.3
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
17.4
5
V
OUT
, 200W (e.g. S375B5C200BL, V375B5C200BL)
Parameter
Efficiency
S375B5C200BL (enhanced efficiency)
V375B5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
Typ
83.0
201
6.25
5.4
±0.02
46
46
251
6.47
8.1
±0.2
40
52
52
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
6.03
0
40.8
28
375V Mini Family
Page 4 of 14
Rev 9.9
05/2018
3075V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5
V
OUT
, 150W (e.g. S375B5C150BL, V375B5C150BL)
Parameter
Efficiency
S375B5C150BL (enhanced efficiency)
V375B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
82
6.03
Typ
85.0
83.4
169
6.25
5.5
±0.02
34.5
34.5
Max
Unit
%
211
6.47
6.5
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
8
V
OUT
, 200W (e.g. S375B8C200BL, V375B8C200BL)
Parameter
Efficiency
S375B8C200BL (enhanced efficiency)
V375B8C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
83
9.36
Typ
87.0
84.2
320
9.7
6
±0.02
28.8
28.8
Max
Unit
%
400
10.1
6.9
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
12
V
OUT
, 300W (e.g. S375B12C300BL, V375B12C300BL)
Parameter
Efficiency
S375B12C300BL (enhanced efficiency)
V375B12C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
85.5
13.7
Typ
89.0
86.7
280
14.3
6
±0.02
28.8
28.8
Max
Unit
%
360
14.9
9
±0.3
25
35
35
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
12
V
OUT
, 200W (e.g. S375B12C200BL , V375B12C200BL)
Parameter
Efficiency
S375B12C200BL (enhanced efficiency)
V375B12C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.2
84.5
13.7
Typ
86.7
85.8
258
14.3
8.5
±0.02
19.2
19.2
Max
Unit
%
323
14.9
10
±0.2
16.67
22.6
22.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Industrial automation systems use microprocessors, digital signal processors (DSPs), and sensor networks to control electromechanical processes. These components are highly sensitive, yet operate in a...
I have been working on a project these days. I need to connect the tiny210 to the PC via miniUSB and use gadgets to identify it as a USB flash drive or SD card. The Linux system installed on my tiny21...
[i=s]This post was last edited by dcexpert on 2021-11-16 11:44[/i]DOOM game porting on STM32F429DISC, controlled by touch screen:Link:
[hide]https://github.com/bane9/STM32DISCOVERY_DOOM[/hide]...
Recently I looked at the 188 protocol for water meters and found that the cumulative flow is 4 bytes, one of which is a decimal place. In the actual process, I found that there is a 7-bit meter, all i...
Learn how the engineering team met the stringent requirements of cordless vacuum cleaner customers: high suction power, small size and light weight, and a long and reliable product life cycle. Learn t...
[i=s]This post was last edited by dontium on 2015-3-19 11:46[/i] [size=4]The first post has been posted here: [url=https://bbs.eeworld.com.cn/thread-319304-1-1.html]https://bbs.eeworld.com.cn/thread-3...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
Microchip's PIC18F46J50 is a low-power, high-performance 8-bit USB microcontroller (MCU) using nanoWatt XLP technology. The current in deep sleep mode can be as low as 13nA, the operating voltage i...[Details]
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
Two simple circuits are implemented to drive two LEDs from a battery powered microprocessor.
This design is based on a circuit that uses three resistors and a microprocessor I/O pin as an input h...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
Microcalorimetry
is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small sample sizes or slow heating rat...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]