Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
77605W Multi-Conductor - 600V Unshielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles
For more Information
please call
1-800-Belden1
General Description:
16 AWG stranded (168x38) bare copper conductors, PVC insulation, oil-resistant overall PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material Dia. (mm)
4
16
168x38
BC - Bare Copper
1.702
5
Total Number of Conductors:
Ground Wire
Ground Wire (Y/N):
Ground Wire AWG:
Ground Wire Stranding:
Ground Wire Conductor Material:
Ground Wire Insulation Material:
Y
16
168x38
BC - Bare Copper
PVC - Polyvinyl Chloride
Insulation
Insulation Material:
Insulation Material
Wall Thickness (mm) Dia. (mm)
2.819
PVC - Polyvinyl Chloride 0.559
Insulation Color Code Chart:
Color
Red
Description
Individually Numbered
Yellow/Green Ground
Outer Shield
Outer Shield Separator Material:
Tissue Tape, 25% Overlap, Min.
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.889
Overall Cable
Overall Nominal Diameter:
10.058 mm
Mechanical Characteristics (Overall)
Storage Temperature Range:
Installation Temperature Range:
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
Min. Bend/Installation:
Min. Bend Radius (Continuous Flexing):
Flex Cycle Rating:
-40°C To +90°C
Flexing: -5°C To +90°C
Flexing: -5°C To +90°C
386.932 Kg/Km
471.509 N
81.280 mm
81.280 mm
81.280 mm
14 Million Flexes
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
AWM Specification:
CSA Specification:
EU Directive 2011/65/EU (ROHS II):
Other Specification:
THHN/THWN Singles
UL Style 2587 (600 V 90°C)
600 V AWM I/II A/B
Yes
AWM/STYLE 10012, AWM/STYLE 2587, AWM I/II A/B, FT1, VDE 0472, Section 803 Oil Test, EU Low
Voltage Directive 2014/35/EC, EU Directive 2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006),
California Proposition 65
Page 1 of 2
10-02-2017
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
77605W Multi-Conductor - 600V Unshielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles
Flame Test
CSA Flame Test:
FT1
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.591
Nom. Capacitance Cond. to Other Cond. & Ground:
Description
Freq. (kHz) Capacitance (pF/m)
111.554
Nom. Cond. to Cond 1.000
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
13.452
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
Revision Number: 0
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 09-27-2017
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Page 2 of 2
10-02-2017