Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
73605W Multi-Conductor - 600V Unshielded, Light to Moderate Flexing Applications Up to 1 Million Flex Life Cycles
For more Information
please call
1-800-Belden1
General Description:
16 AWG stranded (26x30) bare copper conductors, PVC insulation, oil-resistant PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
4
16
26x30
BC - Bare Copper
5
Total Number of Conductors:
Ground Wire
Ground Wire (Y/N):
Ground Wire AWG:
Ground Wire Stranding:
Ground Wire Conductor Material:
Ground Wire Insulation Material:
Y
16
26x30
BC - Bare Copper
PVC - Polyvinyl Chloride
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.022
Insulation Color Code Chart:
Color
Black
Description
Individually Numbered
Yellow/Green Ground
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.035
Overall Cable
Overall Nominal Diameter:
0.361 in.
Mechanical Characteristics (Overall)
Storage Temperature Range:
Installation Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
Min. Bend/Installation:
Min. Bend Radius (Continuous Flexing):
Flex Cycle Rating:
-40°C To +90°C
Flexing: -5°C To +90°C
168 lbs/1000 ft.
102 lbs.
1.800 in.
1.800 in.
1.800 in.
1 Million Flexes
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification:
CSA Specification:
EU Directive 2011/65/EU (ROHS II):
MII Order #39 (China RoHS):
Other Specification:
UL Style 2587 (600 V 90°C)
600 V AWM I/II A/B
Yes
Yes
VDE 0472, Section 803 Oil Test, EU Low Voltage Directive 2014/35/EC, EU Directive
2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006), California Proposition 65
Page 1 of 2
10-02-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
73605W Multi-Conductor - 600V Unshielded, Light to Moderate Flexing Applications Up to 1 Million Flex Life Cycles
Flame Test
CSA Flame Test:
FT1
Suitability
Suitability - Burial:
Yes
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
0.180
Max. Capacitance Conductor to Conductor:
Freq. (MHz) Capacitance (pF/ft)
0.001
34.000
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.100
Max. Operating Voltage - UL:
Voltage
600V
Put Ups and Colors:
Item #
73605W 008100
73605W 0081000
73605W 008500
Putup
100 FT
1,000 FT
500 FT
Ship Weight
20.300 LB
171.000 LB
88.000 LB
Color
GRAY
GRAY
GRAY
Notes
Item Desc
16AWG 26/30 5C UNSHIELDED
16AWG 26/30 5C UNSHIELDED
16AWG 26/30 5C UNSHIELDED
Revision Number: 0
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 09-27-2017
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Page 2 of 2
10-02-2017