EEWORLDEEWORLDEEWORLD

Part Number

Search

AFL2812SY/HB

Description
1-OUTPUT 66 W DC-DC REG PWR SUPPLY MODULE
CategoryPower/power management    The power supply circuit   
File Size242KB,12 Pages
ManufacturerInternational Rectifier ( Infineon )
Websitehttp://www.irf.com/
Download Datasheet Parametric View All

AFL2812SY/HB Overview

1-OUTPUT 66 W DC-DC REG PWR SUPPLY MODULE

AFL2812SY/HB Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
MakerInternational Rectifier ( Infineon )
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage40 V
Minimum input voltage16 V
Nominal input voltage28 V
JESD-30 codeR-XDMA-P12
Maximum load regulation1%
Number of functions1
Output times1
Number of terminals12
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Maximum output voltage12.24 V
Minimum output voltage11.76 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelMILITARY
Terminal formPIN/PEG
Terminal locationDUAL
Maximum total power output66 W
Fine-tuning/adjustable outputYES
Base Number Matches1
PD-94460C
AFL28XXS SERIES
28V Input, Single Output
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
Description
The AFL Series of DC/DC converters feature high power
density with no derating over the full military
temperature range. This series is offered as part of a
complete family of converters providing single and dual
output voltages and operating from nominal +28V or
+270V inputs with output power ranging from 80W to
120W. For applications requiring higher output power,
individual converters can be operated in parallel. The
internal current sharing circuits assure equal current
distribution among the paralleled converters. This series
incorporates International Rectifier’s proprietary
magnetic pulse feedback technology providing
optimum dynamic line and load regulation response.
This feedback system samples the output voltage at
the pulse width modulator fixed clock frequency,
nominally 550KHz. Multiple converters can be
synchronized to a system clock in the 500KHz to 700KHz
range or to the synchronization output of one converter.
Undervoltage lockout, primary and secondary
referenced inhibit, soft-start and load fault protection
are provided on all models.
These converters are hermetically packaged in two
enclosure variations, utilizing copper core pins to
minimize resistive DC losses. Three lead styles are
available, each fabricated with International Rectifier’s
rugged ceramic lead-to-package seal assuring long
term hermeticity in the most harsh environments.
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Contact IR Santa Clara for special
requirements.
AFL
Features
n
16V To 40V Input Range
n
5V, 7V, 8V, 9V,12V,15V and 28V Outputs
Available
n
High Power Density - up to 84W/in3
n
Up To 120W Output Power
n
Parallel Operation with Power Sharing
n
Low Profile (0.380") Seam Welded Package
n
Ceramic Feedthru Copper Core Pins
n
High Efficiency - to 85%
n
Full Military Temperature Range
n
Continuous Short Circuit and Overload
Protection
n
Primary and Secondary Referenced
Inhibit Functions
n
Line Rejection > 40dB - DC to 50KHz
n
External Synchronization Port
n
Fault Tolerant Design
n
Dual Output Versions Available
n
Standard Microcircuit Drawings Available
www.DataSheet4U.com
www.irf.com
1
12/18/06
12-bit encoder and FPGA use RS232 communication
Use rs232 to realize the communication between 12-bit encoder and FPGA. First, FPGA sends two 8-bit data to the encoder. After the encoder detects it, it returns 5 8-bit data at a time. How to use rs2...
735153430 FPGA/CPLD
How to filter a 50Hz 1V triangle wave?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:22[/i] I want to get the third harmonic, and I used TI's Filter Pro to design a bandpass filter. Why is there a problem with the sine wave I ...
星空暖暖的 Electronics Design Contest
Questions about MOS tube VGS(th)
The following two pictures are the VGS(th) parameters of the MOS tube IRF530N. The first picture shows that the turn-on voltage VGS(th) ranges from 2 to 4V under the test conditions of VDS=VGS and ID=...
xiaxingxing Analog electronics
Establishing GPRS connection on CE
I have searched for many answers to similar questions, but couldn't find what I was looking for. I had no choice but to post this question here. On CE, I use AT dial ATD*99***1# CONNECT 115200 ~ }#?}!...
lws Embedded System
How to call up the properties dialog box for setting PPPoE dial-up in wince?
Assume that a new dial-up connection called "pppoe" has been created. Or if there is code provided, you can directly modify the properties in the properties dialog box (such as PAP, CHAP, etc.)...
xwinter123 Embedded System
[Award] [EE Call] LaunchPad Learning Full Experience
Thank you for sharing your recent experiences with the TI LaunchPad and touch daughter board!Event details: https://bbs.eeworld.com.cn/thread-332514-1-1.htmlThe following 13 netizens will receive a TI...
EEWORLD社区 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1179  1720  2835  659  1224  24  35  58  14  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号