EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS1000L-60/BAT

Description
AC/DC CONVERTER 60V 1000W
CategoryPower/power management   
File Size240KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric Compare View All

HWS1000L-60/BAT Overview

AC/DC CONVERTER 60V 1000W

HWS1000L-60/BAT Parametric

Parameter NameAttribute value
typeclosed
battery chemistrylead acid
Battery size-
Number of batteries1
Voltage - nominal60V
Charging current - maximum17A
Charging time-
Voltage - input85 ~ 265 VAC
Power - Max1000W
size/dimensions9.45" long x 5.91" wide x 2.40" high (240.00mm x 150.00mm x 61.00mm)
Installation typeDesktop
Terminal type-
Operating temperature-20°C ~ 74°C
ApprovalCE
characteristicAdjustable output, DC input capability, load sharing, remote switching, telemetry, universal input
weight2300g
HWS600/1000L BAT Series
36V & 60V Battery Charger Power Supplies
Features
u
Low Profile
u
Active Power Factor Correction
u
Universal Input (85 - 265VAC)
u
Low acoustical noise
u
Medical certifications (HWS1000L)
u
Adjustable current limit
u
Constant current style limit
Key Market Segments & Applications
Specifications
Model
Input Voltage range
Inrush Current (115 / 230VAC)
Power Factor
Input Current (100/200VAC)
Temperature Coefficient
Constant Current Set Accuracy
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Parallel Connection
Remote On/Off (CNT)
Voltage Programming
DC Good & Fan Fail Signal
Auxiliary Output
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
(One minute)
Isolation Resistance
Vibration (non operating)
Shock
Immunity
Safety Agency Certifications
Conducted & Radiated EMI
Weight (Typ)
Size (WxHxD)
Warranty
V
A
-
A
-
-
V
-
ms
mA
-
-
-
-
-
-
-
°C
°C
RH
-
-
-
-
-
-
-
-
g
In
yrs
HWS600L
HWS1000L
85 - 265VAC (47 - 63Hz) or 120 - 350VDC
20 / 40
Meets EN61000-3-2 Class A
7.1 / 3.6
12 / 6
<0.02%/°C
±10%
36V: 45 - 52.2V; 60V: 69 - 81V
Yes, cycle AC or Remote On/Off to reset
20ms at 115/230VAC
<0.75mA
100uA at 115VAC 60Hz
(1)
Yes
Yes
Yes
Yes, 1-6V adjusts output (see manual for limits)
Yes, open collector output
12V 0.1A
Green LED = On
-40°C start up. -20 to 74°C, derating linearly to 50% load above 50°C
-40 to +85°C
20 - 90% RH operating, 10 - 95%RH non operating
Variable speed internal fan
Input to Ground 2kVAC, Input to
Input to Ground 2kVAC, Input to
Output 3kVAC, Output to Ground
Output 4kVAC, Output to Ground,
500VAC, Output to CNT 100VA
500VAC, Output to CNT 100VAC
>50M at 25°C & 70%RH, Output to Ground 500VDC
MIL-STD-810F 514.5 Cat. 4, 10
MIL-STD-810F 516.5 Procedure I, VI
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 lvl (3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11
UL, CSA, EN60950-1, UL, CSA, EN60601-1 (1000W only), EN50178, CE Mark
EN55011 / EN55022-B, FCC Class B
1600
2300
2.4 x 4.72 x 7.48”
2.4 x 5.91 x 9.45”
Five Years
(1) 300uA worse case, 265VAC 63Hz
1-800-526-2324 • www.us.tdk-lambda.com/lp/
100
Disclaimer: us.tdk-lambda.com/lp/legal.htm

HWS1000L-60/BAT Related Products

HWS1000L-60/BAT HWS1000L-36/BAT HWS600L-36/BAT
Description AC/DC CONVERTER 60V 1000W AC/DC CONVERTER 36V 1000W AC/DC CONVERTER 36V 600W
type closed closed closed
battery chemistry lead acid lead acid lead acid
Number of batteries 1 1 1
Voltage - nominal 60V 36V 36V
Charging current - maximum 17A 29A 18A
Voltage - input 85 ~ 265 VAC 85 ~ 265 VAC 85 ~ 265 VAC
Power - Max 1000W 1000W 600W
size/dimensions 9.45" long x 5.91" wide x 2.40" high (240.00mm x 150.00mm x 61.00mm) 9.45" long x 5.91" wide x 2.40" high (240.00mm x 150.00mm x 61.00mm) 7.48" long x 2.40" wide x 4.72" high (190.00mm x 61.00mm x 119.90mm)
Installation type Desktop Desktop Desktop
Operating temperature -20°C ~ 74°C -20°C ~ 74°C -20°C ~ 74°C
Approval CE CE CE
characteristic Adjustable output, DC input capability, load sharing, remote switching, telemetry, universal input Adjustable output, DC input capability, load sharing, remote switching, telemetry, universal input Adjustable output, DC input capability, load sharing, remote switching, telemetry, standby output, universal input
weight 2300g 2300g 1600g
The difference between PIC series microcontrollers and MCS-51 series microcontrollers
It can be said that there are three main features: (1) Bus structure: The bus structure of MCS-51 is von Neumann type. The computer fetches instructions and data in the same storage space, and the two...
songbo Microchip MCU
How to pop up the system time and alarm setting dialog box
As the title says, how can I pop up the system time and alarm setting dialog box? I need a framework function, preferably code. Thank you...
woshis Embedded System
Hiring embedded development engineers
Headhunting position [Suzhou] Job responsibilities: 1. Design framework solutions according to requirements; 2. Be responsible for embedded Linux software development and testing; 3. Write related com...
ff318421749 Recruitment
【micropython tutorial】+Tera Term VT configuration
[size=5][b]1. Preface[/b][/size][size=4]I recently took advantage of this event to get a pyboardCN2. This is my first time playing with micropython, so I watched online tutorials and tried it myself. ...
飞扬自我 MicroPython Open Source section
Driver and kernel issues
There is a driver that must be loaded on kernel version 2.6.5 or higher. I want to port this driver to arm. Are there any requirements for the arm kernel?...
a79571843 Embedded System
Help
What to do if the serial port assistant sscom33 cannot be opened...
13938926987 ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1075  383  2814  1306  2608  22  8  57  27  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号