EEWORLDEEWORLDEEWORLD

Part Number

Search

UMYM10-1100-1000

Description
SAFETY MAT 1100X1000MM
CategoryTools and equipment   
File Size704KB,11 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet View All

UMYM10-1100-1000 Overview

SAFETY MAT 1100X1000MM

Safety mats & Area guarding
Um Series
Universal Safety mat System
UM
Rev. 5.11
heavy-Duty four-Wire Presence Sensing mats
with integrated (non-removable) cable,
category 3 controllers, and Perimeter trim
System
• When UM series mats are combined with an MC3, MC4 or MC6
controller (with complete diagnostics), the result is a system
that meets the standard EN 1760-1:1998 and is entitled to
display the CE mark. See below for an overview of the various
components.
mat
• Activation force: 30 kg (66 lb.) per ANSI/RIA 15.06-1999,
ISO 13856-1:2001, ANSI B11.19-2003, and CSA Z432-04
• Conductive plates: 24 gauge galvanealed sheet steel
• Contact yield strength in excess of 20,000 lb./sq. in.; Fork lift
traffic of 12,000 lb.
• Mat housing cross section: 13.5 mm (0.54 in.)
• PVC black or yellow covering materials (other colors available
on request)
• Durometer of 80 (±3) shore A
• Single-piece molded construction
• Mat flammability self extinguishing, meets UL94VO
• IP67 rated
• Operating temperature -37 to 66°C (-35 to 150°F)
• Mat cable: 18-gauge, 4-conductor, 16-strand, 300 VAC
• Cable length: Standard 5 m (16 ft.), Optional 10 m (32 ft.)
controllers
• Safety category 3 device
• DIN-rail mount (MC3)
• NEMA controllers (MC4, MC6)
• 24 VDC or with universal power supply 100 to 240 VAC
trim
• Two-part perimeter and joining trim simplifies installation and
provides a custom appearance
• Aluminum base surrounds mat, the safety yellow PVC cover
secures mat in place, an aluminum cover that is installed in
place of the PVC cover is also available
• Two-part active joining trim joins multiple mats together
• Molded inside and outside corners available as an option
f
r
C
US
Description
An Omron STI Universal Mat system (UM series mat combined
with an MC3, MC4 or MC6) offers a simple method for guarding
personnel around hazardous machines. A Universal Mat system
offers freedom, flexibility, and reduced operator fatigue when
compared with traditional guarding methods such as interlocked
fences, pullback restraints or perimeter barriers.
Full visibility of and access to the work area is maintained. There
is no need to worry about personnel forgetting to replace mechani-
cal barriers or close gates.
how the System Works
The operation of a Universal Mat system is easy to understand.
The mat is a simple, normally open switch. When a specified
minimum weight is applied to the mat the "switch" closes. This
sends a signal to the controller which, in turn, sends a stop signal
to the guarded machine.
Each mat presents four wires to the controller. This provides the
redundancy required to monitor the wiring for open circuits due to
incorrect wiring or physical damage to the wires.
In order to meet many national safety regulations, Omron STI
offers trim to secure the mat to the floor so that it cannot be easily
relocated and therefore become ineffective.
f2
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
Wideband ADC front-end design considerations: Should I use an amplifier or a transformer to drive the ADC? (Part 2)
Q: How do high-speed amplifiers and ADCs differ in power consumption? A: It depends on the amplifier and ADC used. Two typical amplifiers with similar power consumption, the AD83523, has a supply curr...
nmg ADI Reference Circuit
Mini2440 SDcard boot analysis
Mini2440 Driver Analysis Series --------------------------------------- Analysis of Mini2440 SD Card Driver By JeefJiang July, 25th, 2009 Email: Jeefjiang1983@163.com (This article is only for learnin...
幸福的娃 Embedded System
Chip Packaging Encyclopedia
...
wzt PCB Design
The gift redemption speed is really fast
I have a business trip on the 12th and I am a little confused whether to exchange it before or after the trip. I am afraid that the express delivery will be lost if it is piled up too much. I saw the ...
cardin6 Talking
I have a Wanli board with a CAN port. Can I debug CAN?
Do I need at least 2 boards to debug CAN? ?If I use one Wanli board to debug and learn CAN, what should I do? ?Thank you...
yangfeng stm32/stm8
How to collect differential output data with a single chip microcomputer
How to use a single chip microcomputer to collect the differential output data of the tension sensor TJL-1...
fsunboy Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1175  419  2649  52  1049  24  9  54  2  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号