8340-G210-P1E1-A6H131-20A Overview

CIR BRKR MAG 20A 240VAC 80VDC

8340-G210-P1E1-A6H131-20A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic (hydraulic delay)
Rated current20A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles1
Actuator typePush-pull punch
illumination-
Lighting voltage (nominal)-
Installation typePanel mounting
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Description
Single and two pole magnetic circuit breakers with trip-free
mechanism and push/pull on/off manual actuation. A choice of fast
magnetic only or hydraulically delayed switching characteristics (S-
type MO or HM CBE to EN 60934) ensures suitability for a wide range
of applications. Convenient threadneck panel or plug-in mounting,
and with a white push button indicator band showing clearly the
tripped/off position. Available with auxiliary contacts (1 x N/O, 1 x
N/C) for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, power semiconductors.
Standard current ratings and typical internal resistance values
Current rating (A)
Internal resistance (Ω) per pole
-F4/-F5
0.02
0.05
0.08
0.1
0.15
0.2
0.3
0.5
0.75
1
1.25
1.5
1.75
2
2.5
3
4
5
6
8
10
12
15
16
20
25
30
40
50
* 50 % ON duty / 60 min.
583
94
35.6
22.9
9.89
5.02
2.44
0.789
0.392
0.246
0.145
0.10
0.083
0.059
0.048
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02*
< 0.02*
-E1/H1/R1
2 896
531
202
129
57.3
30.5
13.9
4.50
2.19
1.10
0.695
0.487
0.355
0.295
0.174
0.121
0.0729
0.0437
0.0329
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-E2/H2/R2
2 660
542
199
127
55.7
30.5
13.7
4.42
1.82
1.08
0.686
0.472
0.337
0.291
0.168
0.118
0.0687
0.0449
0.0323
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
1-pole
8340-G2...
1
2-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC voltages to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
5,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
switching to trip circuit test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with button down:
1-pole
2-pole
1-pole
2-pole
I
N
0.02...20 A
AC 250 V/3,500A
AC 250 V/3,500A
0.02...50 A
0.02...30 A
25...30 A
AC 250 V/3,500A
AC 250 V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
operating area IP40
terminal area IP00
10 g (57-2000 Hz), ± 0.76 mm (10-57 Hz)
at 0.9 x I
N
other mounting planes: 10 g (57-2000 Hz) at I
N
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
100 g (11 ms) at 1 x I
N
, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x I
N
, direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 70 g per pole
1712
www.e-t-a.de
1
TA8880
A brief introduction to the TA8880 chip...
rain Embedded System
This "soso" is not that "soso"~~~
Hehe, starting from yesterday, I plan to record some small things at work every day, and I hope everyone will join in this sharing. At about 11 o'clock in the morning, a stranger suddenly greeted me a...
soso Talking
Niu Gensheng challenges Jack Ma and Yu Minhong: Who among you can start a business again?
Niu Gensheng was acting as an examiner, and he wanted to ask Jack Ma and Yu Minhong some questions. Niu Gensheng asked, if you both start a business again and enter your respective fields, who would b...
lhy Automotive Electronics
What is the difference between a single board computer and an embedded industrial computer?
Are they used in different fields?...
lzjcjwl Embedded System
Ask about Protel network labeling issues
Can two network labels be placed on a component pin at the same time? For example: [img]http://bbs.21ic.com/upfiles/img/200711/20071125164212102.jpg[/img]...
omantou MCU
Weekly highlights: 2018.7.30-8.3
[size=4]Hi, everyone. It's a new week again. Let's take a look at the good stuff from the past week. [/size] [size=4][color=#ff0000][b]Recommended exciting activities: [/b][/color][/size] [size=4][url...
okhxyyo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 777  2087  421  513  926  16  43  9  11  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号