EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T130-K0DU-7A

Description
CIR BRK THERM-M 7A 480VAC/125VDC
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

4230-T130-K0DU-7A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T130-K0DU-7A - - View Buy Now

4230-T130-K0DU-7A Overview

CIR BRK THERM-M 7A 480VAC/125VDC

4230-T130-K0DU-7A Parametric

Parameter NameAttribute value
Circuit breaker typeThermomagnetic
Rated current7A
Rated voltage - AC480V
Rated voltage - DC125V
Number of poles3
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
[My relationship with TI] My relationship with the msp430 microcontroller
[My relationship with TI] I remember that I just started to get in touch with TI's msp430 series microcontrollers last year. At that time, I participated in the campus advanced electronic design compe...
jianping-sun TI Technology Forum
A layman asks how to generate random bit errors
Experts, I would like to ask: How to randomly generate 400 bit errors in 10,000 bits? ? Is there a function to implement it? Thank you...
1742 Embedded System
Problems with online debugging between wince and vs2005
The host computer has XP installed. I want to use the VS2005 smart application on the host computer to run on the WinCE operating system (not the simulator). The other monitor shows that the two parti...
shileiwhut123 Embedded System
MIPS network TV development, please give some suggestions!
MIPS Technologies is committed to providing the widest range of low-power, high-performance processor cores to semiconductor companies, ASIC developers and system OEMs around the world with significan...
youki12345 Embedded System
Embedded C C++ Language Essentials
Hehe~ some good suggestions! I read it, it's good. It is very helpful to introduce it to everyone for understanding the concept!...
黑衣人 Embedded System
Please tell me some motor parameters of HVACI_Sensorless-setting.h
[align=left][font=normal 宋体, Arial, Helvetica, sans-serif][size=4][color=#000000]Hello everyone, recently I am working on the motor tuning work in the HVACI_Sensorless routine, which involves the adju...
FoCus Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 118  2851  1105  2294  1356  3  58  23  47  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号