Off-line systems with PFC front ends, industrial and process control, distributed power,
medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–Sense to –OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
–0.5 to +525
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
3000
1500
500
–55 to +100
–65 to +125
500 [260]
750 [390]
5 [0.57]
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F [°C]
°F [°C]
in.lbs [N.m]
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High-frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V375A12T600BL2
375A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= –10 to +100 –20 to +125
C
= –20 to +100 –40 to +125
T
= –40 to +100 –40 to +125
H
= –40 to +100 –55 to +125
M
= –55 to +100 –65 to +125
B
Output Power
P
OUT
160W
200W, 264W
300W, 400W
300W, 400W
400W, 600W
400W, 600W
400W, 600W
400W, 600W
600W
400W, 500W, 600W
400W, 600W
600W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail. ≤12
V
OUT
only)
Output Voltage
2
= 2V
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
32
= 32V
36
= 36V
48
= 48V
54
= 54V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
32V
36V
48V
54V
375V Maxi Family
Page 1 of 15
Rev 10.1
09/2018
375V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Input Specifications
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
204.7
429.2
242.5
212.2
446.3
467.5
1.1
Min
250
Typ
375
Max
425
500
247.5
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
Module Output Specifications
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
1
±0.2
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 – 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
32V
36V
48V
54V
–0.5 to 3.1
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 41.9
–0.5 to 47.1
–0.5 to 62.9
–0.5 to 70.2
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 10.
Thermal Resistance and Capacity
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
375V Maxi Family
Page 2 of 15
Rev 10.1
09/2018
375V Input
Module Family Electrical Characteristics (Cont.)
Module Control Specifications
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
V
AVG
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink ≥4mA. See Fig. 2
Module General Specifications
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
[184.3]
7.4
[209.3]
100
3000
1500
500
10
7.3
[207.5]
8.2
[232.5]
115
cURus, cTÜVus, CE
8.1
[230.7]
9.0
[255.7]
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
[grams]
ounces
[grams]
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
375V Maxi Family
Page 3 of 15
Rev 10.1
09/2018
375V Input
Module-Specific Operating Specifications
2V
OUT
, 160W (e.g. S375A2C160BL, V375A2C160BL)
Parameter
Efficiency
S375A2C160BL (enhanced efficiency)
V375A2C160BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
76.0
72.0
2.7
Typ
80.0
73.7
200
2.8
8.4
±0.02
92
92
Max
Unit
%
250
2.9
11
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 264W (e.g. S375A3V3C264BL, V375A3V3C264BL)
Parameter
Efficiency
S375A3V3C264BL (enhanced efficiency)
V375A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.0
120
4.3
4.9
±0.02
92
92
Max
Unit
%
150
4.46
7.8
±0.2
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S375A3V3C200BL, V375A3V3C200BL)
Parameter
Efficiency
S375A3V3C200BL (enhanced efficiency)
V375A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
78.0
4.14
Typ
86.0
78.9
60
4.3
7.9
±0.02
69.7
69.7
Max
Unit
%
75
4.46
9.1
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S375A5C400BL, V375A5C400BL)
Parameter
Efficiency
S375A5C400BL (enhanced efficiency)
V375A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.26
Typ
86.0
82.0
210
6.49
6.6
±0.02
92
97
Max
Unit
%
270
6.72
9
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
375V Maxi Family
Page 4 of 15
Rev 10.1
09/2018
375V Input
Module-Specific Operating Specifications (Cont.)
5V
OUT
, 300W (e.g. S375A5C300BL, V375A5C300BL)
Parameter
Efficiency
S375A5C300BL (enhanced efficiency)
V375A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.0
6.03
Typ
87.0
83.3
80
6.25
8.8
±0.02
69
69
Max
Unit
%
100
6.47
10.2
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
8V
OUT
, 400W (e.g. S375A8C400BL, V375A8C400BL)
Parameter
Efficiency
S375A8C400BL (enhanced efficiency)
V375A8C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.5
9.55
Typ
87.0
83.6
288
9.9
17.9
±0.02
57.5
57.5
Max
Unit
%
360
10.3
19
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
8V
OUT
, 300W (e.g. S375A8C300BL, V375A8C300BL)
Parameter
Efficiency
S375A8C300BL (enhanced efficiency)
V375A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
82
9.36
Typ
87.0
83.1
220
9.7
9.3
±0.02
43.1
43.1
Max
Unit
%
275
10.1
10.8
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 600W (e.g. S375A12C600BL, V375A12C600BL)
Parameter
Efficiency
S375A12C600BL (enhanced efficiency)
V375A12C600BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
86.0
13.7
Typ
89.0
87.1
320
14.3
8.7
±0.02
57.5
57.5
Max
Unit
%
400
14.9
13
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; 75% load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I recently used 28335 to communicate with the host computer. The host computer inquired about the working status of 28335. 28335 needs to reply 20 bytes of data each time. 288335 only sends 16 bytes i...
I am using a z8 cpu with 1k ram and 8k rom. In the boot program, I have used code to copy the data in rom to ram, as shown below: IF COPYPRAM LD R0,#high(_low_pramseg) LD R1,#low(_low_pramseg) LD R2,#...
First: Information display electronic instruments, equipment, household appliances, information display, digital display and various displays, as well as LED display screens (information display, adve...
[color=red][font=宋体][size=10.5pt][color=#000000][align=left]Moderator's note: The original content of this post was written based on the old version of djyos. The process of setting up the environment...
Why can't the external interrupt be enabled in low power mode 0 of msp430g2553? I need some help. It doesn't work in low power mode 1 or 2, but only in mode 3 or 4. The code is as follows: #includevoi...
A ventilator is an instrument that can replace or assist a person's respiratory function. It is suitable for artificial respiration of patients with respiratory failure or even respiratory arrest. I...[Details]
1 Introduction
The multifunctional monitor is a commonly used clinical medical device. It can display the patient's electrocardiogram (ECG), respiration (RESP), blood oxygen saturation (SP...[Details]
1 Overview
Drugs are like a "double-edged sword". They can treat diseases but can also cause serious adverse consequences. The dual nature of drugs depends on whether they are used rationally....[Details]
Keeping the heart environment compact and warm is beneficial in most cases, but it’s another story for electronic heart scanners. When GE Healthcare was designing a scanner that was said to be the fas...[Details]
Implantable Cardivoerter Defibrillators (ICDs) have been in common use for several years. ICDs apply a high voltage pulse between two electrodes connected to the heart, which detects cardiac fibrillat...[Details]
1 Overview
The BP01 pressure sensor is specially designed for monitoring blood pressure and is mainly used in portable electronic sphygmomanometers. It uses a precision thick-film ceramic chip and...[Details]
Controller Area Network (CAN) is a type of fieldbus. It is a serial communication network that effectively supports distributed control or real-time control and is recognized as one of the most pro...[Details]
JTAG Technology Introduction
One disadvantage of shrinking technology is that the complexity of testing small devices increases dramatically. When the board area is large, the board is tested...[Details]
As the price of readers and tags decreases and the global market expands, the application of radio frequency identification (RFID) is increasing day by day. Tags can be powered by readers (passive ...[Details]
To help improve DC/DC conversion efficiency at lighter loads and higher frequencies, Schottky diodes can be integrated into MOSFET chips to form a single package to reduce power dissipation in the ...[Details]
This article first briefly introduces the working principles of current mode and voltage mode and their respective advantages and disadvantages; then discusses the ideal voltage mode using output c...[Details]
Today's mobile phone production testing faces an increasingly complex environment, with challenges of multiple frequency bands and multiple standards, pressure on production test speed, and pres...[Details]
Overview
In recent years, the vigorous development of integrated circuits has created a huge space for the research and application of digital circuits. FPGA has low power consumption, high re...[Details]
Introduction
The MAX2116 P1db data is measured at specific combinations of RF and baseband gain over the adjustable range of these two gains. These data can be used to select gain control se...[Details]