Description
LIQUID LEVEL CONTROL
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size424KB,2 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Compare View All

LLC52BA Online Shopping

Suppliers Part Number Price MOQ In stock  
LLC52BA - - View Buy Now

LLC52BA Overview

LIQUID LEVEL CONTROL

Protection Relays
Pump Controls and Liquid Level Controls
LLC5 SERIES
Liquid Level Controls
Description
The LLC5 provides dual probe conductive liquid level control
in a convenient octal plug-in package. Models are available
for fixed fill or drain operation. Isolated, pulsed DC voltage
on the probes prevents electrolytic plating. Less than 1 mA
of current is used to sense the presence of conductive liquid
between the probes and common. On adjustable units, the
sensitivity adjustment eliminates false tripping caused by
floating debris and foaming agents.
Operation
Drain (Pump-Down Mode):
When the liquid level rises
and touches the high level probe, the output relay and LED
energize and remain energized until the liquid level falls below
the low level probe. The output relay and LED de-energize and
remain de-energized until the liquid rises and touches the high
level probe.
Fill (Pump-Up Mode):
When the liquid level falls below
the low level probe, the output relay and LED energize and
remain energized until the liquid level rises and touches the
high level probe. The output relay and LED de-energize and
remain de-energized until the liquid level again falls below the
low level probe.
8-PIN
Wiring Diagram
HP = HIGH LEVEL PROBE
LP = LOW LEVEL PROBE
C = PROBE COMMON
V = VOLTAGE
Relay contacts are isolated.
Connect common to
conductive tank. Additional
probe is necessary for non-
conductive or insulated tanks.
Metal Tank or use
additional Probe
Features & Benefits
FEATURES
Unique Probe
Protection logic
LED status indicatior
L1
N/L2
BENEFITS
Probes are protected from scale build up through
pulsed DC signal between the probes.
Visual indication of relay engagement in pump-up or
pump-down activity
Allows control of loads for AC voltage
Ordering Information
MODEL
LINE
VOLTAGE
DESCRIPTION
Isolated 5A
SPDT contacts
LLC52AA
LLC52BA
LLC54AA
LLC54AAS
LLC54AF10
LLC54BA
LLC54BAS
LLC56AA
24VAC
24VAC
120VAC
120VAC
120VAC
120VAC
120VAC
230 VAC
For Drain (pump-down) operation with
adjustable sense resistance
For Fill (pump-up) operation with adjustable
sense resistance
For Drain (pump-down) operation with
adjustable sense resistance
For Drain (pump-down) operation with
adjustable sense resistance and reverse
connection (#8 low, #6 high)
For Drain (pump-down) operation with fixed
sense resistance of 10 kΩ
For Fill (pump-up) operation with adjustable
sense resistance
For Fill (pump-up) operation with adjustable
sense resistance and reverse connection
(#8 low, #6 high)
For Drain (pump-down) operation with
adjustable sense resistance
Accessories
BZ1 Front Panel Mount Kit
Provides an easy method of through-the-panel
mounting of 8- or 11-pin plug-in timers, flashers,
and other controls.
NDS-8 Octal 8-pin Socket
8-pin 35mm DIN rail or surface mount. Rated
at 10A @ 300VAC. Surface mounted with two
#6 (M 3.5 x 0.6) screws or snaps onto a 35 mm
DIN rail. Uses PSC8 hold-down clips.
PSC8 Hold-down Clips
Securely mounts plug-in controls in any position.
Provides protection against vibration. Use with
NDS-8 Octal Socket. Sold in pairs.
Note:
use of the PSC8 clips partley covers the LED window of
the LLC5 unit. Use of alternative socket base P1011-6 with its
corresponding hold down clips PSCRB8 do not cover up the LED
window, but the socket base is not DIN rail mountable.
If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/LLC5
Rev: 1-A-062116

LLC52BA Related Products

LLC52BA LLC52AA LLC54AF10 LLC56AA LLC54AAS LLC54AA LLC54BA LLC54BAS
Description LIQUID LEVEL CONTROL LIQUID LEVEL CONTROL LIQUID LEVEL CONTROL LIQUID LEVEL CONTROL LIQUID LEVEL CONTROL CONTROL LIQ LEV 120VAC DRAIN CONTROL LIQ LEV 120VAC FILL FIX CONTROL LIQ LEV 120VAC FILL ADJ
DIY TI Power Management Application
bq24070 single-chip charging and system power path management bq27200[1] Single-cell Li-ion and Li-polymer battery fuel gauge with I2C interface The tps63001[1] is a 96% step-up/step-down converter wi...
蓝雨夜 Analogue and Mixed Signal
SINA31S first power on
Because there is no screen, I have to connect the serial port to see what comes with the board, baud rate 115200 [code]HELLO! BOOT0 is starting! boot0 version : 2.4.0 reg_addr 0x01f00100 =0x00000000 r...
白丁 Embedded System
How many watts of resistor should I choose?
Is the power = (U*U) / R = (220*220) / 100K = 48400 / 100K = 0.484W? I am using a 2010 package chip resistor, which is 0.75W. Will it burn out? And it is always powered on. I hope the experts can give...
oulinzeng Analog electronics
6410 camera demo program
Does anyone in the forum have a simple demo program for 6410 camera (not directshow)? I'm just getting started~~Email: 693427966@qq.com Thank you very much~~~~~~~~...
canycall Embedded System
I am using the lm4f120xl development board. I created a new project in CCS6.0 and connected it to the computer for debugging. It always prompts that there is...
[b][align=left][size=3]The error message is as follows:[/size][/align][align=left][size=3]CORTEX_M4_0: GEL Output: Memory Map Initialization Complete CORTEX_M4_0: GEL: Encountered a problem loading fi...
雪飞 Microcontroller MCU
Sell your own XDS100V1 DSP simulator for $80
I have been selling DSP2812 development boards since the beginning of this year. Since the development board is cheap, fully functional, and can download programs via the serial port, it sold well at ...
pengwr Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1011  1025  55  257  2845  21  2  6  58  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号