Part Number

Search

PAH100S48-15/PV

Description
DC DC CONVERTER 15V 100W
CategoryPower/power management   
File Size240KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

PAH100S48-15/PV Overview

DC DC CONVERTER 15V 100W

PAH100S48-15/PV Parametric

Parameter NameAttribute value
typeisolation module
Number of outputs1
Voltage - Input (minimum)36V
Voltage - input (maximum)76V
Voltage - Output 115V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (maximum)6.7A
Power (W)100W
Voltage - Isolation1.5kV
applicationITE (Business)
characteristicRemote on/off, OCP, OTP, OVP
Operating temperature-40°C ~ 100°C
efficiency86%
Installation typeThrough hole
Package/casing9-DIP module
size/dimensions2.40" long x 2.28" wide x 0.50" high (61.0mm x 57.9mm x 12.7mm)
Control characteristicsEnable, active high level
PAH Series
50W to 200W 48V Input Half brick DC-DC Converters
Features
u
Industry Standard Footprint & Pinouts
u
12V output for driving non-isolated converters
u
Safety Approved
u
Full power at 100ºC baseplate
u
Wide Adjustable Output Range
u
Zero Pre-load
u
ASIC Design
u
No potting materials
Key Market Segments & Applications
Specifications
Model
Efficiency (Typ)
Input Voltage range
Output Voltage Accuracy
Max Ripple & Noise
Max Line Regulation
Max Load Regulation
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Overtemperature
Cooling
Isolation Voltage
Shock
Vibration
Amplitude
Safety Agency Approvals
Weight (Typ)
Size (WxHxD)
Warranty
2.5V
3.3V
5V
12V
15V
24V
28V
48V
%
75-76
79-80
83-84
85-86
86-88
88
VDC
36-76
%
±1.6
mV
150
200
280
250
mV
10
24
30
48
56
96
mV
10
24
30
48
56
96
A
105 - 150% automatic recovery
%
120-160 120-140
125-145
135-155
-
Yes
-
Standard; Low = ON, Open = OFF /P option; Low = OFF, Open = ON)
-
-40ºC to +100ºC baseplate
-
Shutdown between 105 - 130ºC, Auto restart
-
Conduction (See Installation Manual for heatsink selection)
V
Input - Baseplate 1500VAC, Input - Output 1500VAC, Output-Baseplate 500VDC
-
196.1m/s
2
-
Non Operating, 10-55Hz (sweep for 1 min.)
-
0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
-
UL60950-1, CSA60950-1, EN60950-1, CE LVD
g
80
in(mm)
2.28x0.5x2.4 (57.9x12.7x61) See outline drawing
-
2 Years
(1)
(1) See options table.
General: See Installation Manual for full details, test methods of parameters and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
13

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 581  590  1254  2568  1217  12  26  52  25  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号