EEWORLDEEWORLDEEWORLD

Part Number

Search

5404 SL001

Description
CABLE 4COND 22AWG SLATE 1000'
CategoryWire/cable   
File Size222KB,4 Pages
ManufacturerAlpha Wire
Websitehttp://www.alphawire.com/zh-CN/
Environmental Compliance
Download Datasheet Parametric View All

5404 SL001 Overview

CABLE 4COND 22AWG SLATE 1000'

5404 SL001 Parametric

Parameter NameAttribute value
Cable typemulti-core
Number of conductors4
Wire gauge22 AWG
Number of wire strands7/30
conductor materialCopper, tin plated
Sheath (insulation) materialPolyvinyl chloride (PVC)
Sheath (insulation) diameter0.358"(9.09mm)
Shield type-
length1000.0'(304.8m)
Casing colorslate color
gradeISO 10993
characteristicbiocompatibility
Voltage600V
Operating temperature-30°C ~ 105°C
usecommunication, control
Sheath (insulation) thickness0.0630"(1.600mm)
conductor insulationPolyvinyl chloride (PVC)
shielding material-
Shielding range-
Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207
Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com
Customer Specification
PART NO. 5404
Construction
Diameters (In)
1) Component 1
a) Conductor
b) Insulation
(1) Color Code
Cond
1
2
2) Cable Assembly
a) Twists:
b) Orientation:
c) Core Wrap
3) Jacket
a) Color(s)
b) Ripcord
Color
BLACK
BROWN
4 X 1 COND
22 (7/30) AWG Tinned Copper
0.032" Wall, Nom. PVC
Alpha Wire Color Code E
Cond
3
4
4 Components Cabled
4.8 Twists/foot (min)
Components to be arranged from INSIDE
LAYER to OUTSIDE LAYER
Nonwoven Polyester Tape, 25% Overlap, Min.
0.063" Wall, Nom.,PVC
0.358 (0.377 Max.)
Color
RED
ORANGE
Cond
Color
0.030
0.094
Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
1 End 810 Denier Nylon
ALPHA WIRE-* P/N 5404 4C 22 AWG
XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C
600V OR AWM 21896 105C 600V SUN RES 60C OIL
VW-1 OR CRU AWM I/II A/B 105C 600V
FT4 CE ROHS (SEQ FOOTAGE)
* = Factory Code
c) Print
Applicable Specifications
Has anyone made a directional motion sensor?
A few days ago, a friend told me that he wanted to make a series of smart homes, which involved a human motion sensor. At that time, I said that there were not many such sensors, and then added that i...
czl618 Industrial Control Electronics
[Repost] How to judge the quality of PCB circuit board
[align=left][color=rgb(25, 25, 25)][font="]With the rapid development of mobile phones, electronics, and communications industries, the PCB circuit board industry has also grown rapidly. People have h...
皇华Ameya360 Power technology
[GD32L233C-START Review] 8. ADC and DAC Test
I. Overview The specific model of the MCU on the GD32L233C-START development board is GD32L233CCT6, which integrates an ADC unit and a DAC unit. Among them, the ADC has 14 channels (10 external channe...
xinmeng_wit GD32 MCU
I would like to ask how to enable this interrupt request?
It says: If the update interrupt or DMA request is enabled... I want to know how to enable the request? After looking through all the registers, I didn't see any enable request, but I did see enable i...
electrics stm32/stm8
Newcomer report
I just arrived and I feel great. I hope everyone will support me....
jiaju3721 Talking
Urgent: Is there anyone familiar with ZigBee 3.0 certification?
I have a problem with ZigBee 3.0 certification. I would like to ask an expert for help. Thank you....
pklite RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1422  408  2617  2021  315  29  9  53  41  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号