TECHNICAL DATA SHEET
ADAPTOR
SMC PLUG – SMA PLUG
39S132-S00L5
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
SMC side:
SMA side:
IEC 60169-9, CECC 22140, US MIL-C-39012
IEC 60169-15; EN 122110; MIL-STD-348A, Fig. 310
Documents
N/A
Material and plating
Connector parts
Center contact
Outer contact SMC side
Outer contact SMA side
Dielectric
Coupling nut SMA side
Gasket
Material
CuBe
Brass
CuBe
PTFE
CuBe or equivalent
Silicone
Plating
Auro Dur, gold plated
Auro Dur, gold plated
Auro Dur, gold plated
Gold, 0.1 µm
RF_35/12.04/3.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
1/2
TECHNICAL DATA SHEET
ADAPTOR
SMC PLUG – SMA PLUG
Electrical data
Impedance
Frequency
Return loss
50
DC to 6 GHz
35 dB, DC to 1 GHz
30 dB, 1 to 3 GHz
20 dB, 3 to 6 GHz
0.05 x
f(GHz)
dB
1x10
3
M
5 m, SMC side
3 m, SMA side
2.5 m, SMC side
2 m, SMA side
750 V rms, 50 Hz, at sea level
250 V rms, 50 Hz, at sea level
90 dB up to 1 GHz
39S132-S00L5
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
Working voltage
RF-leakag
Mechanical data
Mating cycles
Coupling nut retention
Coupling test torque
Recommended torque
Center contact captivation: axial
SMC side
min. 500
N/A
max. 0.71 Nm
0.25 Nm to 0.35 Nm
10 N
SMA side
min. 500
270 N
max. 1.7 Nm
0.8 Nm to 1.1 Nm
10 N
Environmental data
Temperature range
Thermal shock
Vibration
Moisture resistance
Corrosion
-55°C to +155°C
MIL-STD-202, Meth.
MIL-STD-202, Meth.
MIL-STD-202, Meth.
MIL-STD-202, Meth.
107, Cond. B
204, Cond. D
106
101, Cond B
Tooling
N/A
Suitable cables
N/A
Weight
Weight
5.9 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/12.04/3.0
Draft
Inge Mühlauer
Date
21/12/04
Approved
Sa. Krautenbacher
Date
17.03.14
Rev.
d00
Engineering change number
14-0352
Name
T. Krojer
Date
17.03.14
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
2/2