EEWORLDEEWORLDEEWORLD

Part Number

Search

5300FE 0091000

Description
CBL 2COND 18AWG FRPVC SHLD
CategoryWire/cable   
File Size103KB,3 Pages
ManufacturerBELDEN
Download Datasheet Parametric Compare View All

5300FE 0091000 Overview

CBL 2COND 18AWG FRPVC SHLD

5300FE 0091000 Parametric

Parameter NameAttribute value
Cable typemulti-core
Number of conductors2
Wire gauge18 AWG
Number of wire strands7/26
conductor materialCopper, tin plated
Sheath (insulation) materialPolyvinyl chloride (PVC), upright
Sheath (insulation) diameter0.162"(4.11mm)
Shield typefoil
length1000.0'(304.8m)
Casing colorWhite
gradeUL type CMR
characteristicdrain wire, drawstring
Voltage300V
Operating temperature-20°C ~ 75°C
usesafety, sound
Sheath (insulation) thickness0.0170"(0.432mm)
conductor insulationPolypropylene (PP)
shielding materialaluminum
Shielding range100%
Part Number:
5300FE
Security & Sound, 2 Conductor 18 AWG, BC, O/A Foil, CMR
Product Description
Security & Commercial Audio Cable, Riser-CMR, 2-18 AWG stranded bare copper conductors with polyolefin insulation, Beldfoil® shield and PVC jacket with
ripcord
Technical Specifications
Product Overview
Environmental Space:
Suitable Applications:
Indoor - Riser
Intercom/PA Systems, Sound/Audio Systems
Physical Characteristics (Overall)
Conductor
AWG Stranding
18
7x26
Material
No. of Conductors
TC - Tinned Copper 2
2
18 AWG
Conductor Count:
Conductor Size:
Insulation
Material
Nominal Diameter Nominal Wall Thickness
0.008 in
PP - Polypropylene 0.062 in
Color Chart
Number Color
1
2
Black
Red
Outer Shield Material
Type
Material
Material Trade Name Coverage [%] Drainwire Material
100 %
Drainwire AWG Drainwire Construction n x D
Solid
Tape Aluminum/Polyester Beldfoil®
Outer Jacket Material
Material
TC - Tinned Copper 24
Nominal Diameter Nominal Wall Thickness Ripcord
0.017 in
Yes
PVC - Polyvinyl Chloride 0.162 in
Construction and Dimensions
Cabling
Twists
6.9 twist/ft
Print Legend:
NEW GENERATION(R) BY BELDEN 5300FE CMR 75C 2C18 SHIELDED (UL) E108998 OR C(UL) CMG----FT4 (2 FT., 7 DIGIT SEQUENTIAL) FEET
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR
6.5 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
16.25 Ohm/1000ft

5300FE 0091000 Related Products

5300FE 0091000 5300FE 008U1000 5300FE 008500 5300FE 0081000 5300FE 0021000 5300FE 0031000 5300FE 0041000 5300FE 0061000 5300FE 0071000 5300FE 0101000
Description CBL 2COND 18AWG FRPVC SHLD SHLD MULTICOND CABLE 2COND 18AWG 1000 SHLD MULTICOND CABLE 2COND 18AWG 500F SHLD MULTICOND CABLE 2COND 18AWG 1000 CBL 2COND 18AWG FRPVC SHLD CBL 2COND 18AWG FRPVC SHLD CBL 2COND 18AWG FRPVC SHLD CBL 2COND 18AWG FRPVC SHLD CBL 2COND 18AWG FRPVC SHLD CBL 2COND 18AWG FRPVC SHLD
Cable type multi-core - - - multi-core multi-core multi-core multi-core multi-core multi-core
Number of conductors 2 - - - 2 2 2 2 2 2
Wire gauge 18 AWG - - - 18 AWG 18 AWG 18 AWG 18 AWG 18 AWG 18 AWG
Number of wire strands 7/26 - - - 7/26 7/26 7/26 7/26 7/26 7/26
conductor material Copper, tin plated - - - Copper, tin plated Copper, tin plated Copper, tin plated Copper, tin plated Copper, tin plated Copper, tin plated
Sheath (insulation) material Polyvinyl chloride (PVC), upright - - - Polyvinyl chloride (PVC), upright Polyvinyl chloride (PVC), upright Polyvinyl chloride (PVC), upright Polyvinyl chloride (PVC), upright Polyvinyl chloride (PVC), upright Polyvinyl chloride (PVC), upright
Sheath (insulation) diameter 0.162"(4.11mm) - - - 0.162"(4.11mm) 0.162"(4.11mm) 0.162"(4.11mm) 0.162"(4.11mm) 0.162"(4.11mm) 0.162"(4.11mm)
Shield type foil - - - foil foil foil foil foil foil
length 1000.0'(304.8m) - - - 1000.0'(304.8m) 1000.0'(304.8m) 1000.0'(304.8m) 1000.0'(304.8m) 1000.0'(304.8m) 1000.0'(304.8m)
Casing color White - - - red orange color yellow blue Purple black
grade UL type CMR - - - UL type CMR UL type CMR UL type CMR UL type CMR UL type CMR UL type CMR
characteristic drain wire, drawstring - - - drain wire, drawstring drain wire, drawstring drain wire, drawstring drain wire, drawstring drain wire, drawstring drain wire, drawstring
Voltage 300V - - - 300V 300V 300V 300V 300V 300V
Operating temperature -20°C ~ 75°C - - - -20°C ~ 75°C -20°C ~ 75°C -20°C ~ 75°C -20°C ~ 75°C -20°C ~ 75°C -20°C ~ 75°C
use safety, sound - - - safety, sound safety, sound safety, sound safety, sound safety, sound safety, sound
Sheath (insulation) thickness 0.0170"(0.432mm) - - - 0.0170"(0.432mm) 0.0170"(0.432mm) 0.0170"(0.432mm) 0.0170"(0.432mm) 0.0170"(0.432mm) 0.0170"(0.432mm)
conductor insulation Polypropylene (PP) - - - Polypropylene (PP) Polypropylene (PP) Polypropylene (PP) Polypropylene (PP) Polypropylene (PP) Polypropylene (PP)
shielding material aluminum - - - aluminum aluminum aluminum aluminum aluminum aluminum
Shielding range 100% - - - 100% 100% 100% 100% 100% 100%
In a WINCE+ARM system, what effect does adding a const modifier to a global, immutable array have? Reduce memory usage? Increase program execution speed? Can ROM be used as RAM in ARM?
In a WINCE+ARM system, what effect does adding a const modifier to a global, immutable array have? Reduce memory usage? Increase program execution speed? Can ROM be used as RAM in ARM?...
joalin Embedded System
FPC production process
[size=14px] To date, almost all FPC manufacturing processes have been processed using the subtractive method (etching method). According to Carbon Technology, copper-clad laminate is usually used as t...
方学放 PCB Design
DE2 board example
High score reward, who has the routine program for DE2 board?...
monica150373637 Embedded System
What do the codes on the Fairchild FDA18N50/FQPF8N60C products mean?
I found a Fairchild FDA18N50 with code 1A52AZ FQPF8N60C Product code 1A14CUWhat do these mean? There is no batch number on the product. Does this mean the batch number? If so, how do you understand it...
pjyok Integrated technical exchanges
4 Common Problems with Isolating Signals and Power
High voltage circuit designs require isolation to protect operators, communicate with low voltage circuits, and eliminate unwanted noise within the system. Digital isolators provide a simple and relia...
qwqwqw2088 Analogue and Mixed Signal
Typical application circuit of Darlington tube
1. Used in high-power switching circuits, motor speed regulation, and inverter circuits. 2. Drive small relays The circuit that uses CMOS circuit to drive high-sensitivity relay through Darlington tub...
rain Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2671  1681  2556  1728  2138  54  34  52  35  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号