EEWORLDEEWORLDEEWORLD

Part Number

Search

D4NL-4BFG-B-NPT

Description
SWITCH SAFETY DPST 3A 240V
Categoryaccessories   
File Size4MB,20 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4NL-4BFG-B-NPT Online Shopping

Suppliers Part Number Price MOQ In stock  
D4NL-4BFG-B-NPT - - View Buy Now

D4NL-4BFG-B-NPT Overview

SWITCH SAFETY DPST 3A 240V

D4NL-4BFG-B-NPT Parametric

Parameter NameAttribute value
circuitDPST-NO/NC + DPST-NC
switch functionon-off, off-on
Rated current3A(AC),270mA(DC)
Rated voltage - AC240V
Rated voltage - DC250V
Actuator typeBoard disconnected
Installation typeBase installation
Terminal typescrew terminal
Intrusion protectionIP67 - dust and water resistant
characteristicLED indicator
force3059gf
release force1530gf
Pre-trip0.354"(9.0mm)
Differential travel-
overtravel-
Operating temperature-10°C ~ 55°C
work location-
Electrical life500,000 cycles
Mechanical life1,000,000 cycles
Guard Lock Safety-door Switch
D4NL
CSM_D4NL_DS_E_8_1
Best-selling Guard Lock Safety-door
Switch Available in Several
Compact, Multi-contact Models
• Selectable Operation Key insertion direction and
adjustable mounting ensure installation flexibility.
• Built-in switches with multiple-contact construction are
available.
• Key holding force of 1,300 N minimum.
• Can be used for either standard loads or microloads.
• Lineup includes models with a conduit size of M20.
• IP67 degree of protection.
• Variety of
metallic heads available.
Conforms to ISO 14119.
Be sure to read the
“Safety Precautions”
on page 16.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
Switch (Standard type)
Switch (Metallic release key type)
D4NL-@@@@-@@@
1 2 3 4
5 6 7
1. Conduit Size
1: Pg13.5
2: G1/2
4: M20
2. Built-in Switch (with Door Open/Closed Detection Switch and
Lock Monitor Switch Contacts)
A: 1NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts)
B: 1NC/1NO (slow-action contacts) + 2NC (slow-action contacts)
C: 2NC (slow-action contacts) + 1NC/1NO (slow-action contacts)
D: 2NC (slow-action contacts) + 2NC (slow-action contacts)
E: 2NC/1NO (slow-action contacts) + 1NC/1NO (slow-action contacts)
F: 2NC/1NO (slow-action contacts) + 2NC (slow-action contacts)
G: 3NC (slow-action contacts) + 1NC/1NO (slow-action contacts)
H: 3NC (slow-action contacts) + 2NC (slow-action contacts)
3. Head Mounting Direction and Material
F: Four mounting directions possible (Front-side mounting at
shipping)/plastic
D: Four mounting directions possible (Front-side mounting at
shipping)/metal
4. Door Lock and Release
A: Mechanical lock/24 VDC solenoid release
B: Mechanical lock/110 VAC solenoid release
G: 24 VDC solenoid lock/mechanical release
H: 110 VAC solenoid lock/mechanical release
5. Indicator
B: 10 to 115 VAC/VDC (orange LED indicator)
6. Release Key Type
Blank: Standard (resin)
4:
Special release key (resin)
(Note: Release keys are provided.)
7. Release Key Position
Blank: Bottom
S:
Front
D4NL-@@@@-@@@-SJ
1 2 3 4
5 6 7
1. Conduit Size
2: G1/2 (1-conduit)
4: M20 (1-conduit)
2. Built-in Switch
E: 2NC/1NO + 1NC/1NO
F: 2NC/1NO + 2NC
G: 3NC + 1NC/1NO
H: 3NC + 2NC
3. Head Material
F: resin
4. Door Lock and Release
A: Mechanical lock/ 24 VDC solenoid release
G: 24 VDC solenoid lock/ mechanical release
5. Indicator
B: 10 to 115 VAC/VDC (orange LED indicator)
6. Release Key Type
Blank: Standard (metal)
7. Release Key Position
Blank: Bottom
Operation Key
D4DS-K@
1
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (horizontal)
5: Adjustable mounting (horizontal/vertical)
1
TI will release a new BLE protocol stack next month
[color=#000]I heard that TI will release a new BLE protocol stack next month, and the UART driver will be updated at that time, which will improve the performance.[/color] If you remember what happene...
wangfuchong Wireless Connectivity
Mixed Language Programming
How to mix assembly and C languages in the IAR environment of 430? Is there any good teaching material or information? Does anyone have a sample program? ? Thank you!...
zdk Microcontroller MCU
The keil5 program error says that my function is not defined, but I clearly defined it.
I need help, the file usart2.h contains the uart_init() function, but when I call the function it says I have not defined it, I don't know what's going on, I hope you can help me solve this problem, t...
zhuuu RF/Wirelessly
Simple CNC DC Power Supply Paper
Simple CNC DC Power Supply Paper...
maker Power technology
About IIC bus development
[i=s] This post was last edited by dirty on 2016-2-25 15:53 [/i] I have come across some IIC applications that use EEPROM (such as IC 24LC128). What is the development environment for this source code...
dirty MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2405  2020  2701  1224  1021  49  41  55  25  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号