Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input85 ~ 264 VAC
Voltage - Output 124V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)630mA
Power (W)15W
applicationITE (Business)
characteristicOVP,SCP
Operating temperature0°C ~ 70°C (with derating)
efficiency75%
Installation typeThrough hole
Package/casing4-DIP module
size/dimensions2.75" long x 1.77" wide x 0.79" high (69.9mm x 45.0mm x 20.1mm)
line conditioning±0.5%
load regulation±1%
ApprovalCE,CSA,EN,UL
weight0.177 lbs (80.29g)
KPS-A Installation Manual
ENGLISH
General Safety Instructions:
READ SAFETY INSTRUCTIONS
Servicing:
These products are not customer serviceable TDK-Lambda UK LTD and their authorised agents only are permitted
to carry out repairs.
Critical Components:
These products are not authorised for use as critical components in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the Managing Director of TDK-
Lambda EMEA.
Product Usage:
These products are designed for use within a host equipment which restricts access to authorised competent
personnel.
This product is a component power supply and is only to be installed by qualified persons within other equipment and
must be not operated as a stand alone product.
This product is for sale to business to business customers and can be obtained via distribution channels.
It is not intended for sale to end users.
This product is a component power supply and does not fall within the scope of the EMC directive. Compliance with
the EMC directive must be considered in the final installation. Please contact your local TDK-Lambda office.
Environmental:
These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be used.
Environment:
This power supply is a switch mode power supply for use in applications within a Pollution Degree 2, overvoltage
category II environment. Material Group IIIb PCB’s are used within it.
Output Loading:
The output power taken from the power supply must not exceed the rating stated on the power supply label, except
as stated in the product limitations in this handbook.
Input Parameters:
This product must be operated within the input parameters stated in the product limitations in this handbook.
End of Life Disposal:
The unit contains components that require special disposal. Make sure that the unit is properly disposed of at the
end of its service life and in accordance with local regulations.
RISK OF ELECTRIC SHOCK
High Voltage Warning:
Dangerous voltages are present within the power supply. The professional installer must protect service personnel
from inadvertent contact with these dangerous voltages in the end equipment.
WARNING:
When installed in a Class 1 end equipment, this product must be reliably earthed and professionally
installed.
The (+) or (-) output(s) can be earthed or left floating.
The unit cover(s)/chassis (where applicable) must not be made user accessible.
The mains input connector is not acceptable for use as field wiring terminals.
Page 1 of 16
17171 issue 4 Sept 2016
Reduce the allegro brd layout file version from 17.2 to 16.6
[i=s] This post was last edited by yepeda on 2019-5-5 17:26 [/i] [color=#000][backcolor=rgb(252, 252, 252)][font="]Due to the strict restrictions on cadence versions, once upgraded to a higher version...
yepeda PCB Design
Ask for help after dsp program expansion
After C54x program memory expansion, when ovly=1, are the contents of 20000h and 30000h the same? How to judge?...
cumter DSP and ARM Processors
PhD thesis - Pattern tracking rules based on integral variable structures
Based on the law of pattern tracking of integral variable structure...
lorant FPGA/CPLD
msp430g2553 io port input and output
msp430g2553 P1 port is used as input first and then as output. Why can't the value of P1IN correctly indicate the level of the io port? P1 io port is used as input to connect ad. Why can't the output ...
luowhu Microcontroller MCU
Let's learn algorithms together. Recommended books (XVII) Algorithm Design Manual
[align=center][size=5][color=#0000ff]Why do I recommend these materials? [/color][/size][/align] [size=5][color=#0000ff] [/color][/size] [size=4][color=#000000] There has always been a saying in the s...
tiankai001 Download Centre
MSP430F149 about __no_init problem
In order to prevent some variables in the program from being reinitialized after the watchdog is reset, I defined some variables as __no_init. As a result, after the watchdog is reset, the variable is...
nuonuoluoya Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1361  603  1406  1692  2152  28  13  29  35  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号