Parameter NameAttribute value
capacitance1.9pF
Tolerance±0.25pF
Voltage - Rated25V
Temperature CoefficientC0G,NP0
Operating temperature-55°C ~ 125°C
characteristicHigh Q value, low loss
grade-
applicationRF, microwave, high frequency
Installation typeSurface mount, MLCC
Package/casing0805 (2012 Metric)
size/dimensions0.079" long x 0.049" wide (2.00mm x 1.25mm)
Height - Installation (maximum)-
Thickness (maximum)0.057"(1.45mm)
lead spacing-
Lead form-
VJ HIFREQ Series
www.vishay.com
Vishay Vitramon
Surface Mount Multilayer
Ceramic Chip Capacitors for High Frequency
FEATURES
Case size 0402, 0603, 0805
Available
High frequency
Ultra-stable dielectric material
Available
Non-magnetic copper termination “C”
Lead (Pb)-free terminations code “X”
Tin / lead termination code “L”
Available
Surface mount, wet build process
Reliable Noble Metal Electrode (NME) system
Made with a combination of design, materials and tight
process control to achieve very high field reliability
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details
DESIGN TOOLS
(click logo to get started)
APPLICATIONS
RF and microwave
Broadband communication
Satellite communication
Base stations
Medical instrumentation and test
Military devices (radar, communication, etc.)
Wireless devices
ELECTRICAL SPECIFICATIONS
Note
• Electrical characteristics at 25 °C unless otherwise specified
Operating Temperature:
-55 °C to +125 °C
Capacitance Range:
0402: 0.1 pF to 82 pF
0603: 0.1 pF to 470 pF
0805: 0.1 pF to 1.5 nF
Voltage Rating:
25 V
DC
to 250 V
DC
Temperature Coefficient of Capacitance (TCC):
C0G (D): 0 ppm/°C ± 30 ppm/°C from -55 °C to +150 °C with
zero (0) V
DC
applied
Dissipation Factor (DF):
C0G (D): 0.05 % max. at 1.0 V
RMS
and 1 MHz
for values
1000 pF
C0G (D): 0.05 % max. at 1.0 V
RMS
and 1 kHz
for values > 1000 pF
Aging Rate:
0 % maximum per decade
Insulation Resistance (IR):
at +25 °C and rated voltage 100 000 M minimum or
1000
F,
whichever is less
at +125 °C and rated voltage 10 000 M minimum or
100
F,
whichever is less
Dielectric Strength Test:
performed per method 103 of EIA-198-2-E.
Applied test voltages:
200 V
DC
-rated: min. 250 % of rated voltage
> 200 V
DC
-rated: min. 200 % of rated voltage
Revision: 19-Jun-2018
Document Number: 45071
1
For technical questions, contact:
mlccrf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Inspection methods for technical parameters of CCD sensors
Our unit has a DINI12 level, a Zeiss dini12 electronic level. Now we want to know the test method of its CCD sensor technical parameters. Please teach me, thank you! The simple information is as follo...
sunjun530 Test/Measurement
Beginners Help
After installing the driver, the program still cannot be written...
过客. 51mcu
MDK startup code graphical configuration script
MDK not only provides a text interface to edit the initialization code, but also provides a graphical interface to edit the initialization code. Its graphical interface is controlled by a set of scrip...
柳叶舟 Microcontroller MCU
Is there any way to facilitate the installation and disassembly of the stamp hole module?
How do you usually connect the module with stamp holes (half-through holes) on the edge? Solder directly on the motherboard? Would it be troublesome to disassemble it, especially if you don't have a h...
wangfuchong DIY/Open Source Hardware
[PLC] How to solve the internal error 8021 when retrieving the device control block for this port in VB serial communication?
Recently, I made a Mitsubishi FX2nPLC industrial control host computer program using vb6. I used computer-specific communication protocol mode 4. When debugging, I used a laptop. The Santak USB to ser...
LOCKROSOON Embedded System
Ask about the ISP download line
Are the ISP download cables of AT89S51 and STC different? Because I saw the "24-pin parallel port to ten-pin" download cable, and the other one is the "nine-pin serial port-232 to TTL-microcontroller ...
zl_felix MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 391  1094  1622  2873  2570  8  23  33  58  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号