EEWORLDEEWORLDEEWORLD

Part Number

Search

777-LR-TS

Description
3-PHASE OVERLOAD RELAY/190-480
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size661KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet View All

777-LR-TS Online Shopping

Suppliers Part Number Price MOQ In stock  
777-LR-TS - - View Buy Now

777-LR-TS Overview

3-PHASE OVERLOAD RELAY/190-480

Protection Relays
Motor and Pump Protection - 3-Phase Motor Protection
777 SERIES
3-Phase Current & Voltage Monitor
Description
The 777 is a fully programmable electronic overload relay
designed to protect any motor drawing 2-800 full load amps
(external CTs are required above 90 amps). The 777 (family
of products) is for 3-phase 200-480VAC applications, with
several specialized units for other voltage ranges and unique
applications. Common applications include conveyor systems,
HVAC equipment, saws and grinders, fan motors, and almost
any pumping application. Some unique applications include use
with a Subtrol
®
equipped Franklin submersible motor to detect
high motor temperatures and applications where a fast linear
trip is required.
All of the overload relays provide unsurpassed protection by
combining overload, voltage, phase loss and reversal, voltage
and current unbalance, power monitoring, and underload based
on current in one package. For standalone applications, the units
incorporate a 3-digit LED display that is used for programming,
providing real-time operational information and displaying
diagnostic codes to aid in troubleshooting a fault condition. The
units also feature a communications port that can be used with
communication modules listed in the 777 accessories section to
form a Modbus, DeviceNet™, Profibus, or Ethernet network. Up
to 99 units can be remotely monitored and controlled from a PC,
PLC, or SCADA system, and data logging through a PC with the
optional Solutions software. This capability allows for a simple,
cost-effective way to meet new requirements for arc-flash safety.
Wiring Diagram
TYPICAL WIRING DIAGRAM
MODEL
777
TYPICAL WIRING DIAGRAM FOR
FOR MODEL
777 (2 to 90 amps)
(20 TO 90 amps)
Features & Benefits
FEATURES
CURRENT TRANSFORMER WIRING DIAGRAM FOR MODEL 777
(80 to 800 amps)
BENEFITS
Visual indication for programming, viewing real-time
voltage or current, and last fault code
Allows usage on wide range of systems
Choose from automatic, semi-automatic, or manual to
best meet individual application needs
Program separate restart delay time for rapid cycle
protection, motor cool down, and dry-well recovery
Increases safety through remote display of real-time
data and fault history, without the need to open the
cabinet. Aids with arc flash safety regulations
Reset can be done through pushbutton on relay or
remotely with optional 777-MRSW or OL-RESET
remote reset kit
Compatible with Modbus, DeviceNet™, Profibus, or
Ethernet using optional communications module
Built-in display
Programmable voltage
and current settings
3 selectable
restart options
3 programmable restart
delay timers
LITTELFUSE RECOMMENDS
USING CTs WITH TERMINALS TO
SIMPLIFY INSTALLATION.
Remote display
compatibility
12 - 16 AWG
STRANDED
WIRE
Flexible reset
Network
communications
capability
Ordering Information
See next page.
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/777
www.littelfuse.com/
Rev: 1-A-062816
Problems and solutions of substrate in PCB design
Regarding the problems that may occur in the substrate during the PCB design process, the main problems are various soldering problem phenomena and signs, such as: cold solder joints or solder joints ...
ESD技术咨询 PCB Design
How to make a child window movable with the mouse in WinCE (i.e., move a window without a title)?
How to make a child window movable with the mouse in WinCE (i.e., move a window without a title)?...
sapt Embedded System
[Show samples] + Experience sharing on applying for free samples from TI
[b] I came into contact with TI because of the electronics competition. The MSP430 is my favorite. Its ultra-low power consumption and streamlined instruction set give it unparalleled performance. TI ...
LaughSpeak TI Technology Forum
Questions about UCOS
I started to learn UCOS today, but I am confused after reading Shao Beibei's book. 1. Is running UCOS on XP the same as porting UCOS to PC? In the first 4 examples of Shao's book, two folders, bc31 an...
rightnow10 Real-time operating system RTOS
About 149 ADC
I would like to ask all the experts, when the 8 external analog inputs of 149 are not enough, can A8 and A9 be used to sample the external analog inputs? If so, how should they be set? Thank you!...
guangtonggg Microcontroller MCU
Which Xilinx chip families are supported by Xilinx ISE series versions?
I recently got my hands on a learning board, Xinlinx Virtex II Pro. I won't say much about my newbie's journey. I first looked for development software and asked my senior for ISE14.3 and the matching...
logitech66 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2443  1255  2247  2488  927  50  26  46  51  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号