EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS75AF-15

Description
Single output 50W ~ 150W
File Size2MB,19 Pages
ManufacturerDensei-Lambda (TDK)
Websitehttp://www.densei-lambda.com/indexe.html
Download Datasheet View All

ZWS75AF-15 Overview

Single output 50W ~ 150W

ZWS-AF
-SERIES
Single output 50W ~ 150W
Model name
ZWS150AF
ZWS 100AF-5/
Series Name
Output Power
Option
blank : Molex connector,
PCB type
A : Molex connector,
with-cover type
J : JST connector,
PCB type
JA : JST connector,
with-cover type
ZWS100AF
Active Filter
contained
PC Board Type Power Supply
Output Voltage
Features
ZWS75AF
ZWS50AF
(Low Voltage Directive)
2 year warranty
marking (Low Voltage Directive)
Active Filter contained, PFHC type
Applicable to peak output wattage 120% (12V, 15V, 24V output)
Low leakage current 0.5mA max
Equipped with Remote ON/OFF control
(with-cover type excluded) and output variable voltage
2 year warranty
Specifications
1. Input voltage range
2. Power factor
3. Output Voltage range
4. Cooling
5. Operating ambient
temperature
(Standard mounting)
85~265VAC (47~63Hz) , 120~370VDC universal input
0.99 (typ) 100VAC at full load, 0.95(typ) 200VAC at full load
10%
Convection cooling or Forced air cooling
ZWS50AF,75AF,
Convection cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
ZWS100AF
ZWS150AF
6. Withstand voltage
7. Safety standard
8. CE marking
9. EMI
10. Immunity
11. PFHC
12. Functions
Convection cooling -10°C~+50°C:100%,+60°C:60% (with cover:-10°C~+40°C:100%,+50°C:60%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
Convection cooling -10°C~+40°C:100%,+60°C:50% (with cover:-10°C~+30°C:100%,+45°C:50%)
Forced air cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Input-output : 3kVAC (20mA) , Input-FG : 2kVAC (20mA) , Output-FG : 500VAC (100mA) for 1 min
Approved by UL1950
, CSA950(C-UL)
, EN60950(TUV)
and EN50178(TUV)
Conforms to Low Voltage Directive
Meets to EN55011-B,EN55022,FCC-B,VCCI-B
Meets to EN50082-2(EN61000-4-2,-3,-4,-5,-6,-7,-8,-11)
Meets to EN61000-3-2
Over voltage protection,Over current protection,Remote on/off control(for open frame type only)
Product lineup
Model name
ZWS50AF-5
ZWS50AF-12
ZWS50AF-15
ZWS50AF-24
ZWS75AF-5
ZWS75AF-12
ZWS75AF-15
ZWS75AF-24
ZWS100AF-5
ZWS100AF-12
ZWS100AF-15
ZWS100AF-24
ZWS150AF-5
ZWS150AF-12
ZWS150AF-15
ZWS150AF-24
Nominal
output voltage
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
Max.
output current
10A
4.3A
3.5A
2.1A
15A
6.3A
5.0A
3.2A
20A
8.5A
6.7A
4.3A
30A
12.5A
10A
6.3A
Note 1
Note 1
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
Max. peak
output current
-
5.2A
4.2A
2.6A
-
7.5A
6.0A
3.8A
-
10A
8.0A
5.0A
-
15A
12A
7.5A
Max. average
output power
50.0W
51.6W
52.5W
50.4W
75.0W
75.6W
75.0W
76.8W
100.0W
102.0W
100.5W
103.2W
150.0W
150.0W
150.0W
151.2W
Max. peak
output power
-
62.4W
63.0W
62.4W
-
90.0W
90.0W
91.8W
-
120.0W
120.0W
120.0W
-
180.0W
180.0W
180.0W
UL
CSA
EN
Note1 : Duration at peak current : 10 seconds max. within Max. average output power.
Based on the data under normal installation and without cover type. Needs output derating
according to installation method or ambient temperature condition.
: Safety standard approved
59
Beginner's guide to STC51 microcontroller
I am a beginner in 51 single-chip microcomputers. So far, I have only learned the basic programming skills without any practical application. This feels a bit boring. Is there any practical applicatio...
萤点 MCU
DSP power chip selection
I looked at the schematic diagram of the DSP2812 board. Some use three-terminal voltage regulators for 1.8V and 3.3V power supplies, while others use tps767d301. I want to ask if there is a big differ...
xzyxtt DSP and ARM Processors
The ESP32-C3 module of Anxinke failed to run after burning MicroPython 1.1.17
E (57) boot_comm: can't run on lower chip revision, expected 2, found 3 ESP-ROM:esp32c3-20200918 Build:Sep 18 2020 rst:0x3 (RTC_SW_SYS_RST),boot:0xd (SPI_FAST_FLASH_BOOT) Saved PC:0x403d0f8...
molin2050 MicroPython Open Source section
How to choose MOSFET indicators? System design of ACDC and DCDC? PCB layout and heat dissipation? Have you watched these useful videos?
When I was looking for information on Friday, I saw the video launched by Vicor again. I remember that when it was promoted, everyone gave good feedback, so I recommend it again.Quick Access Links...
soso Power technology
Garbage problem, when pulling data, the error table already exists
I use Pull to pull data from the server to the mobile device. The first time, there is no problem because the data table and error table are specified when Pulling. ... rda.Pull(this.tbFillTableName.T...
zhaojg0924 Embedded System
Hercules Industrial Automation Applications
I chose Hercules for the industrial automation project framework because of its security. I have used other MCUs to do industrial control projects before, but I always felt that they caused interferen...
fxyc87 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1516  1410  265  306  2684  31  29  6  7  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号