EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS30-12

Description
1-OUTPUT 30 W AC-DC PWR FACTOR CORR MODULE
Categorysemiconductor    Analog mixed-signal IC   
File Size2MB,19 Pages
ManufacturerDensei-Lambda (TDK)
Websitehttp://www.densei-lambda.com/indexe.html
Download Datasheet Parametric View All

ZWS30-12 Online Shopping

Suppliers Part Number Price MOQ In stock  
ZWS30-12 - - View Buy Now

ZWS30-12 Overview

1-OUTPUT 30 W AC-DC PWR FACTOR CORR MODULE

ZWS30-12 Parametric

Parameter NameAttribute value
Number of functions1
Maximum total output power30 W
Maximum limit input voltage265 V
Minimum limit input voltage85 V
Maximum operating temperature60 Cel
Minimum operating temperature-10 Cel
stateDISCONTINUED
packaging shapeRECTANGULAR
Package SizeMICROELECTRONIC ASSEMBLY
Terminal formUNSPECIFIED
terminal coatingTIN LEAD
Terminal locationUNSPECIFIED
Packaging MaterialsUNSPECIFIED
Temperature levelCOMMERCIAL
Number of outputs1
Maximum output voltage 113.2 V
Minimum output voltage 110.8 V
Rated output voltage 112 V
Analog IC other typesAC-DC PWR FACTOR CORR MODULE
Maximum load adjustment factor0.8000 %
ZWS-AF
-SERIES
Single output 50W ~ 150W
Model name
ZWS150AF
ZWS 100AF-5/
Series Name
Output Power
Option
blank : Molex connector,
PCB type
A : Molex connector,
with-cover type
J : JST connector,
PCB type
JA : JST connector,
with-cover type
ZWS100AF
Active Filter
contained
PC Board Type Power Supply
Output Voltage
Features
ZWS75AF
ZWS50AF
(Low Voltage Directive)
2 year warranty
marking (Low Voltage Directive)
Active Filter contained, PFHC type
Applicable to peak output wattage 120% (12V, 15V, 24V output)
Low leakage current 0.5mA max
Equipped with Remote ON/OFF control
(with-cover type excluded) and output variable voltage
2 year warranty
Specifications
1. Input voltage range
2. Power factor
3. Output Voltage range
4. Cooling
5. Operating ambient
temperature
(Standard mounting)
85~265VAC (47~63Hz) , 120~370VDC universal input
0.99 (typ) 100VAC at full load, 0.95(typ) 200VAC at full load
10%
Convection cooling or Forced air cooling
ZWS50AF,75AF,
Convection cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
ZWS100AF
ZWS150AF
6. Withstand voltage
7. Safety standard
8. CE marking
9. EMI
10. Immunity
11. PFHC
12. Functions
Convection cooling -10°C~+50°C:100%,+60°C:60% (with cover:-10°C~+40°C:100%,+50°C:60%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
Convection cooling -10°C~+40°C:100%,+60°C:50% (with cover:-10°C~+30°C:100%,+45°C:50%)
Forced air cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Input-output : 3kVAC (20mA) , Input-FG : 2kVAC (20mA) , Output-FG : 500VAC (100mA) for 1 min
Approved by UL1950
, CSA950(C-UL)
, EN60950(TUV)
and EN50178(TUV)
Conforms to Low Voltage Directive
Meets to EN55011-B,EN55022,FCC-B,VCCI-B
Meets to EN50082-2(EN61000-4-2,-3,-4,-5,-6,-7,-8,-11)
Meets to EN61000-3-2
Over voltage protection,Over current protection,Remote on/off control(for open frame type only)
Product lineup
Model name
ZWS50AF-5
ZWS50AF-12
ZWS50AF-15
ZWS50AF-24
ZWS75AF-5
ZWS75AF-12
ZWS75AF-15
ZWS75AF-24
ZWS100AF-5
ZWS100AF-12
ZWS100AF-15
ZWS100AF-24
ZWS150AF-5
ZWS150AF-12
ZWS150AF-15
ZWS150AF-24
Nominal
output voltage
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
Max.
output current
10A
4.3A
3.5A
2.1A
15A
6.3A
5.0A
3.2A
20A
8.5A
6.7A
4.3A
30A
12.5A
10A
6.3A
Note 1
Note 1
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
Max. peak
output current
-
5.2A
4.2A
2.6A
-
7.5A
6.0A
3.8A
-
10A
8.0A
5.0A
-
15A
12A
7.5A
Max. average
output power
50.0W
51.6W
52.5W
50.4W
75.0W
75.6W
75.0W
76.8W
100.0W
102.0W
100.5W
103.2W
150.0W
150.0W
150.0W
151.2W
Max. peak
output power
-
62.4W
63.0W
62.4W
-
90.0W
90.0W
91.8W
-
120.0W
120.0W
120.0W
-
180.0W
180.0W
180.0W
UL
CSA
EN
Note1 : Duration at peak current : 10 seconds max. within Max. average output power.
Based on the data under normal installation and without cover type. Needs output derating
according to installation method or ambient temperature condition.
: Safety standard approved
59
How to split high-speed differential signals without loss
The front-end amplifier uses AD8370 VGA to output differential signals, which need to be split into 4 channels and sent to 2 AD9250s for sampling. The early design used a mini-circuit 4-channel power ...
南无阿弥陀佛 ADI Reference Circuit
How to use C8051F020 to drive ZLG7289?
Please help me! #include#includevoid Delayms(unsigned int i) //Delay ims { unsigned int j; for(;i0;i--) for(j=12000;j0;j--); } void SysClkIn() //Configure system clock 12Mhz { OSCXCN=0X77; Delayms(1);...
晓_枫 51mcu
RF communication! nRF2401 and nRF24L01 power regulation is invalid
Hello everyone, I have a problem and I am a little confused. I want to see if there are any comrades who have similar problems. The two RF communication boards I designed recently use the RF chips nRF...
tuzi2 Embedded System
Lumen study notes 3 LM3S8962 development board installation
Some people may ask if this is simple, I don't think so, I still write down some of my experience to avoid taking detoursThis development board is old,The main board is LM3S8962, and can be externally...
ddllxxrr Microcontroller MCU
Haier microcontroller chip is suitable for motor control applications such as electric vehicles
Shanghai Haier Integrated Circuit Co., Ltd. announced that its HR6P78 microcontroller chip has begun to be launched on the market. This is the latest product in the company's HR6P series 8-bit microco...
frozenviolet Automotive Electronics
Zero voltage quasi-resonance for communication power supply
Zero voltage quasi-resonance for communication power supply...
zbz0529 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2468  1880  307  146  349  50  38  7  3  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号