EEWORLDEEWORLDEEWORLD

Part Number

Search

84137080

Description
SSR GN IP20 125A/240VAC DC INPUT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size562KB,8 Pages
ManufacturerSensata
Environmental Compliance
Download Datasheet Parametric View All

84137080 Online Shopping

Suppliers Part Number Price MOQ In stock  
84137080 - - View Buy Now

84137080 Overview

SSR GN IP20 125A/240VAC DC INPUT

84137080 Parametric

Parameter NameAttribute value
Installation typeBase installation
circuitSPST-NO(1 Form A)
Output typeAC, zero crossing
Voltage - input3 ~ 32VDC
Voltage - Load24V ~ 280V
Load current125A
Terminal typescrew terminal
Package/casingHockey Puck
Supplier device packaging-
Datasheet
GN Series
AC Output SSRs
Current rating 10 and 125 Amps
Output voltage 24-280 VAC and 48-660 VAC
Available with or without IP20 touch-safe cover
LED Input Status Indicator
UL Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
EMC Compliant to level 3
For Generation 3 datasheet
click here
Panel Mount
PRODUCT SELECTION
Control Voltage
3-32 VDC
18-36 VAC
90-280 VAC
10 A
84134000
84134002
84134001
25 A
84134010
84134012
84134011
50 A
84134020
84134022
84134021
75 A
84134030
84134032
84134031
100 A
84134040
84134042
84134041
125 A
84134080
84134082
84134081
AVAILABLE OPTIONS
Operating Voltage
0:
24-280 VAC/Zero Voltage Turn-On
1:
48-660 VAC/Zero Voltage Turn-On
2:
24-280 VAC/Instantaneous Turn-On
3:
48-660 VAC/Instantaneous Turn-On
Series
Thermal Pad
Blank:
Not included
H:
Included
8413
Required for valid part number
For options only and not required for valid part number
>
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
4
0
1
Rated Load
Current
0:
10 Amps
1:
25 Amps
2:
50 Amps
3:
75 Amps
4:
100 Amps
8: 125
Amps
U
0
H
Touch Safe Cover
4:
Not included (IP00)
7:
Included (IP20)
Control Voltage
0:
3-32 VDC
1:
90-280 VAC
2:
18-36 VAC
OUTPUT SPECIFICATIONS
(1)
Description
Operating Voltage (47-440Hz) [Vrms]
Transient Voltage [Vpk]
(2)
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
280 VAC
24-280
600
0.1
500
660 VAC
48-660
1200
0.25
500
OUTPUT SPECIFICATIONS
(1)
Description
Maximum Load Current [Arms]
(3)
Minimum Load Current [mArms]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
1 Second surge current (Apk. Ta=25°C)
50/60 Hz
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Heat Sink for Rated Current @ 40°C
[°C/W]
10 A
10
500
150/175
50
1.35
0.4
110/120
5
25 A
25
50
275/300
85
1.35
0.4
380/370
2
50 A
50
100
710/750
150
1.35
0.25
2520/2320
1
75 A
75
100
1050/1100
225
1.3
0.16
5500/5000
0.7
100 A
100
100
1120/1200
300
1.3
0.16
6270/6000
0.5
125 A
125
100
1600/1700
375
1.25
0.11
12800/12050
0.5
Do not forget to visit us at:
www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
What instruments do hardware engineers need?
I would like to ask everyone: In addition to the commonly used multimeter, oscilloscope, function generator, adjustable power supply, and dummy load. What other useful instruments are there?...
sfcsdc Analog electronics
[Transfer] The history and open source projects of quadcopters
[b]Quadcopter History Review[/b][p=null, 2, left][color=rgb(85, 85, 85)]Quadcopter is a type of micro-aircraft and also a type of intelligent robot. [/color][/p][p=null, 2, left][color=rgb(85, 85, 85)...
chenzhufly Robotics Development
Can LDO be used if the voltage difference exceeds 10V?
Can LDO be used if the voltage difference exceeds 10V?...
ieuieu Analogue and Mixed Signal
Searching for data buffer of program-controlled switch
Our company is engaged in the development of billing software for program-controlled switches. Now we need a billing buffer to store call bills. The buffer is mainly used to store call bills. It is a ...
aolin Embedded System
List of digital broadcasting standards around the world
Various digital television standards are now being tested and used in various places....
flyingdsp RF/Wirelessly
About adjusting the precision of op07 integrated operational amplifier
I recently made a signal conditioning board using OP07, but the voltage of the input signal and the output signal are not proportional, and the measured data is very discrete. I hope you can give me s...
HB1174346953 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1635  1842  1890  2830  2527  33  38  39  57  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号