EEWORLDEEWORLDEEWORLD

Part Number

Search

25492 BK005

Description
MULTI-PAIR 4COND 24AWG BLK 100'
CategoryWire/cable   
File Size221KB,4 Pages
ManufacturerAlpha Wire
Websitehttp://www.alphawire.com/zh-CN/
Environmental Compliance
Download Datasheet Parametric View All

25492 BK005 Overview

MULTI-PAIR 4COND 24AWG BLK 100'

25492 BK005 Parametric

Parameter NameAttribute value
Cable typeMultiple pairs
Number of conductors4 (2 twisted pairs)
Wire gauge24 AWG
Number of wire strands7/32
conductor materialCopper, tin plated
Sheath (insulation) materialPolyurethane (PU)
Sheath (insulation) diameter0.216"(5.49mm)
Shield typefoil
length100.0'(30.5m)
Casing colorblack
gradeISO 10993, UL type 20668
characteristicBiocompatible, drain wire, drawstring
Voltage300V
Operating temperature-30°C ~ 90°C
use-
Sheath (insulation) thickness0.0320"(0.813mm)
conductor insulationPolyvinyl chloride (PVC)
shielding materialaluminum
Shielding range100%
Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207
Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com
Customer Specification
PART NO. 25492
Construction
Diameters (In)
1) Component 1
a) Conductor
b) Insulation
(1) Color Code
Pair
1
c) Pair
(1) Twists:
2) Cable Assembly
a) Twists:
b) Orientation:
c) Core Wrap
3) Shield:
a) Foil Direction
b) Drain Wire
4) Jacket
a) Color(s)
b) Ripcord
Color
WHITE-BLACK
2 X 1 PAIR
24 (7/32) AWG Tinned Copper
0.010" Wall, Nom. PVC, Semi Rigid
Alpha Wire Color Code B
Pair
2
Color
WHITE-BROWN
Pair
Color
0.024
0.044
2/Cond Cabled Together
9.6 Twists/foot (min)
2 Components Cabled
8.0 Twists/foot (min)
Components to be arranged from INSIDE
LAYER to OUTSIDE LAYER
Nonwoven Polyester Tape, 25% Overlap, Min.
Alum/Mylar Tape, 25% Overlap, Min.
Foil Facing In
24 (7/32) AWG Tinned Copper
0.032" Wall, Nom.,Polyurethane (TPU)
0.216 (0.229 Max.)
Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
1 End 810 Denier Nylon
ALPHA WIRE-* P/N 25492
XTRAGUARD(R) 2 RU AWM 20668 VW-1 --- LLXXXXXX CSA
c) Print
AWM I/II A/B 90C 300 VOLTS FT1 CE
ROHS (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
Applicable Specifications
Please tell me the principle of plugging holes
Please don't laugh at me, I'm a newbie. Please help me introduce the principle of PCB plugging, thank you....
神不留名 PCB Design
Application skills/Implementation of AC sampling technology in power monitoring system based on single chip microcomputer
The system uses 8031 single-chip microcomputer to realize AC sampling of power parameters, displays the real-time values of frequency, voltage and current through LED display, gives sound and light al...
rain MCU
single phase inverter
single phase inverter...
青城山下 Analog electronics
IDC room remote power control solutions and related solutions
Intelligent PDU ( Reachctrl Power ) Technology Advantages   ● By replacing the original household power strip, the industrial-grade power supply standard is achieved, eliminating safety hazards such a...
serverwei Power technology
Help: Can you give me a schematic diagram of how to convert CF card to IDE? Thank you very much!
Help: Can you give me a schematic diagram of how to convert CF card to IDE? Thank you very much!...
wzp9999 Embedded System
"Lanting Preface" written by Chu Suiliang
Share with those who like calligraphy. Please enjoy....
ssbrida Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 511  1097  2756  1299  104  11  23  56  27  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号