EEWORLDEEWORLDEEWORLD

Part Number

Search

HCC05DRES

Description
CONN EDGE DUAL FMALE 10POS 0.100
CategoryThe connector   
File Size277KB,3 Pages
ManufacturerSullins Connector Solutions
Environmental Compliance
Download Datasheet Parametric View All

HCC05DRES Overview

CONN EDGE DUAL FMALE 10POS 0.100

HCC05DRES Parametric

Parameter NameAttribute value
card typeUnspecified - Bilateral
genderfemale head
Number of positions/plates/rows5
Number of pins10
Card thickness0.062"(1.57mm)
Number of rows2
spacing0.100"(2.54mm)
readingpair
characteristic-
Installation typePanel mounting
Terminationwelding eyelet
Contact materialcopper beryllium
Contact platinggold
Contact plating thickness30.0µin(0.76µm)
Contact typeFully corrugated pipe
colorblue
Flange characteristicsSide mounting opening, unthreaded, 0.125" (3.18mm) diameter
Operating temperature-65°C ~ 125°C
Material - InsulationPolybutylene terephthalate (PBT)
8
7
6
5
4
3
2
1
REVISIONS
REV.
A
ECO. NO
1750
DESCRIPTION
INITIAL RELEASE
DATE
7-10-08
BY
MNH
F
E
F
D
B
A
E
.100 2.54
2X
.125 3.18
E
.075[1.90]
CARDSLOT
C
F
D
A
.186 4.72
.245 6.22
.431 10.95
.265 6.73
INSERTION
DEPTH
D
FITS
C
.043 MIN HOLE
.032 0.81
_ _C_ _ DSXH
.025 0.64
.160±.025 4.06±0.64
TAIL LENGTH
C
A
SECTION A - A
CONTACT MARKINGS
B 1 2 3 ... 60 B
A 1 2 3 ... 60 A
B
B
A
NOTES:
1. INSULATOR MATERIAL: SEE PART NUMBER CODING
2. CONTACT MATERIAL: SEE PART NUMBER CODING
3. PLATING: SEE PART NUMBER CODING
CONTACT ID
4. OPERATING TEMPERATURE: SEE PART NUMBER CODING
SCALE 2:1
5. PROCESSING TEMP: SEE PART NUMBER CODING
6. UL FLAMMABILITY RATING: 94V-0
7. VOLTAGE RATING: 600 VDC MINIMUM AT SEA LEVEL.
8. CURRENT RATING: 3 AMP PER CONTACT
9. VOLTAGE DROP: 30 MILLI VOLT AT RATED CURRENT
10. INSULATION RESISTANCE: 5000 MEGA OHM
11. CONNECTOR IDENTIFICATION: THE PART SHALL BE MARKED WITH A PART
NUMBER AND BARCODE
12. BOARD THICKNESS ACCOMMODATED: .062 .008"
13. BOARD INSERTION FORCE: 16 OZ MAX PER CONTACT PAIR WHEN USING A .062" TEST BLADE.
INTERNAL INSPECTION TO BE PER SULLIN'S WORK INSTRUCTION W17.3-01.
14. BOARD WITHDRAWAL FORCE: 1 OUNCE MINIMUM PER CONTACT PAIR USING .062" PCB
8
7
6
5
CUSTOMER COPY
UNLESS OTHERWISE SPECIFIED:
DATE
DRAWN
NAME
Pb
R
oHS COMPLIANT
4
DIMENSIONS ARE IN INCHES[MM]
TOLERANCES:
ANGULAR: 30'
.XX= .02 [.508]
.XXX= .005 [.1270]
.XXXX= .0005 [.0127]
SURFACE FINISH: 63 Ra
7-10-08
MNH
REMOVE ALL BURRS AND SHARP EDGES .010 MAX
THE INFORMATION HEREIN CONTAINS
PROPIETARY INFORMATION OF
SULLINS ELECTRONICS AND IS NOT
DESCRIPTION
TO BE REPRODUCED, USED OR
DISCLOSED TO OTHERS FOR ANY
PURPOSE EXCEPT AS SPECIFICALLY
PART NUMBER
AUTHORIZED IN WRITING BY AN
OFFICER OF SULLINS ELECTRONICS.
CONNECTOR, .100 CC LP
REV
A
_ _ C _ _ DSX _
SIZE DWG. NO.
INTERPRET DIMENSIONS AND GEOMETRIC
TOLERANCING
PER: ANSI Y14.5M-1994
3
2
C
C11127
1
A
SHEET 1 OF 3
SCALE: 2:1
FILE NAME: Z:\COMPONENTS\Part Assemblies\Customer Drawings\Customer Drawings for Catalog\C11127, _ _C_ _DSX _ PRINT: 7/10/2008
EEWORLD University Hall----TI CC2652 allows you to easily implement Zigbee and Thread applications and product development
TI CC2652 allows you to easily implement Zigbee and Thread applications and product development : https://training.eeworld.com.cn/course/4559...
hi5 RF/Wirelessly
By the way, why do we have to pause the KEIL software simulation to see the results?
For example, let's say the LED light flashes. Previously, the software simulation can be seen directly on the IO interface. Now it does not move when running. Only when you pause debugging can you fin...
hgmmym stm32/stm8
What are some good ways to protect the algorithm programs in the equipment in the industrial control industry?
What are some good ways to protect the algorithm programs in the equipment in the industrial control industry?...
gas Industrial Control Electronics
MSP432 Launchpad cannot be used
Error connecting to the target: (Error -1063 @ 0x0) Device ID is not recognized or is not supported by driver. Confirm device and debug probe configuration is correct, or update device driver. (Emulat...
zhyuxi Microcontroller MCU
Is there anyone who can repair electrical appliances?
Now, how about the maintenance business?...
qw2850212 Talking
The difference between polarized capacitors and non-polarized capacitors
[font=仿宋_GB2312][size=4]1. The principles are the same. (1) Both store and release charges; (2) The voltage on the plates (here the electromotive force of accumulated charges is called voltage) cannot...
lzcqust Discrete Device

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1846  845  1601  2657  840  38  17  33  54  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号