LineVoltage……………………...90VACto264VAC
InputFrequency………………………..47Hzto63Hz
Noloadinputpower……………...……………..<0.5W
InrushCurrent(cold)….……lessthen30Aat115VAC
or60Aat230VAC
OperatingTemperature……………..…...20ºCto70ºC
StorageTemperature…………..………..20ºCto85ºC
Cooling…………………………..FreeAirConvection
Efficiency………………………….…...….89%91%
HoldupTime……………………...…20msat115VAC
OvervoltageType………………………….…latchoff
OverloadProtection……...…………..….Autorecovery
Within150%ratedload
Safety:
Designedinfullcompliancewith………...UL609501
EN609501
ANSI/AAMIES606011
EN606011
EMI………………...……………….…….FCCclassB
EN6100033
EMS………………...……EN6100042,3,4,5,6,11
TheDG300Seriesisa300WattSemiopenframe
powersupplythatis4.2”x8”x1.65”providing5.4Watts
percubicinch.EachunithasabuiltinActivePower
FactorCorrectionandtheefficiencyofthisseriesis
between89%to91%dependingonmodel.ACinputand
DCoutputareMolexterminalblocks.
1.Dimensionsshowninmmasleft.Tolerance:+/1mm
2.Size:106.7X203.2X42(mm)4.2X8.0X1.65(inch)
3.Connectors:
ACinput:TerminalblocksFan,Remotesense,LED:Molex504502A
DCoutput:Terminalblocksorequivalent
Jan. 2014
DG3007(M)
DG3008(M)
DG3003(M)
DG3009(M)
DG30014(M)
DG300H(M)
300
300
300
300
300
300
+12V
+15V
+18V
+24V
+48V
+60V
0
0
0
0
0
0
25
20
17
12.5
6.3
5
30
24
20.5
15
7.6
6
+11.9V~+12.10V
+14.90V~+15.10V
+17.90V~+18.10V
+23.80V~+24.20V
+47.90V~+48.10V
+58V~+62V
½½
100mVpp
100mVpp
150mVpp
200mVpp
200mVpp
200mVpp
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Note:(M)indicatesmedicalmodel.Usewhenspecifyingamedicalpowersupplye.g.DG3007M
Max.loadfanlocation
MedicalIsolationgrade
Jan. 2014