CIR BRKR MAG 15A 240VAC 80VDC
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

8340-F125-P1M2-A3H0-15A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F125-P1M2-A3H0-15A - - View Buy Now

8340-F125-P1M2-A3H0-15A Overview

CIR BRKR MAG 15A 240VAC 80VDC

8340-F125-P1M2-A3H0-15A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic
Rated current15A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles2
Actuator typepress slice
illumination-
Lighting voltage (nominal)-
Installation typePanel mounting
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
1
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
1747
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
1
TI China University---2012 Texas Instruments China Educators Conference
[b]Meeting Notice[/b] Hello, teachers from all the partner laboratories of TI China University Program! The University Program Department of Texas Instruments plans to hold the "2012 Texas Instruments...
qwqwqw2088 Analogue and Mixed Signal
[Application Note] Using digital potentiometer AD5292, operational amplifier OP184 and MOSFET to build a system with output current boost...
[b][size=4]Using the AD5292 digital potentiometer, the OP184 operational amplifier, and MOSFETs to build a programmable high-voltage source with increased output current[/size][/b] [b][size=4] [/size]...
dontium ADI Reference Circuit
PCB board
How to calculate the price of a PCB board?...
zhonghuadianzie PCB Design
The difference between DSP and ordinary MCU
Consider an example of digital signal processing, such as a finite impulse response (FIR) filter. In mathematical terms, an FIR filter is a series of dot products. Take an input quantity and an ordina...
黑衣人 DSP and ARM Processors
SensorTile SD Storage Application
Following the analysis of the SD storage program last time, this time we will change the program to what we want. Since the weather is the result of a long-term detection, the sampling interval can be...
supermiao123 MEMS sensors
Strengthen physical exercise after work
People who have just entered society and have no self-discipline tend to stay up late, eat and drink excessively, and do not exercise. Their physical condition is getting worse and worse, and they bec...
Demmo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1117  849  589  1357  2692  23  18  12  28  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号