A range of dc rated multi-layer chip capacitors from
0.47pF to 22µF and in case sizes 0603 to 8060 in
C0G/NP0 and X7R dielectrics. Suitable for all general
purpose and high reliability applications where package
size and reliability are important. All are manufactured
using Syfer’s unique wet process and incorporate
precious metal electrodes.
Dissipation Factor
Ageing Rate
Range Dimensions – Standard MLCC Ranges
Length
(L1)
mm/inches
1.6 ± 0.2
0.063 ± 0.008
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
5.7 ± 0.4
0.225 ± 0.016
5.7 ± 0.4
0.225 ± 0.016
9.2 ± 0.5
0.36 ± 0.02
14.0 ± 0.5
0.55 ± 0.02
20.3 ± 0.5
0.8 ± 0.02
Width
(W)
mm/inches
0.8 ± 0.2
0.031 ± 0.008
1.25 ± 0.2
0.05 ± 0.008
1.6 ± 0.2
0.063 ± 0.008
2.5 ± 0.3
0.1 ± 0.012
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
6.30 ± 0.4
0.25 ± 0.016
5.0 ± 0.4
0.197 ± 0.016
6.3 ± 0.4
0.25 ± 0.016
10.16 ± 0.5
0.4 ± 0.02
12.7 ± 0.5
0.5 ± 0.02
15.24 ± 0.5
0.6 ± 0.02
Max. Thickness
(T)
mm/inches
0.8
0.013
1.3
0.051
1.6
0.063
2.0
0.08
2.0
0.08
2.5
0.1
2.5
0.1
4.2
0.16
4.2
0.16
2.5
0.1
4.2
0.16
2.5
0.1
Termination Band
(L2)
mm/inches
min
0.10
0.004
0.13
0.005
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.5
0.02
0.5
0.02
0.5
0.02
max
0.40
0.015
0.75
0.03
0.75
0.03
0.75
0.03
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.5
0.06
1.5
0.06
1.5
0.06
Size
0603
0805
1206
1210
1808
1812
1825
2220
2225
3640
5550
8060
Custom chip sizes not included in the table, but larger than 2225, can be considered with minimum tooling charges. Please refer specific requests direct to the sales office.
Max thickness relates to standard components and actual thickness may be considerably less. Thicker parts, or components with reduced maximum thickness, can be considered by request – please refer
The low power consumption of 430 is very suitable for designing two-wire products. What have you done?I have just completed the design of an intelligent transmitter, with various signal inputs and 4-2...
Regarding FPGA floating point questions. When performing floating point calculations, do we have to use floating point operations? Can we use the method of left shift first and then adjust? Will the c...
When single-step debugging GPIOPinTypeGPIOOutput(GPIO_PORTD_BASE, GPIO_PIN_4|GPIO_PIN_5);, looking at the disassembled code, I found that the program does not jump in the GPIODirModeSet subroutine and...
In today's society, heart disease has seriously affected people's life safety. Many patients with sudden heart attacks are threatened because they cannot get timely treatment. Traditional ECG monito...[Details]
Currently, it is impossible to dynamically obtain patient information in medical monitoring. Once the patient's condition worsens, emergency treatment cannot be implemented in the first place, and the...[Details]
TD-SCDMA terminal conformance test includes three types of tests: RF index test (reference standard: 3GPPTS34.122), protocol signaling test (reference standard: 3GPPTS34.123) and other tests (refer...[Details]
Due to the needs of medical development, in many cases, general thermometers can no longer meet the requirements of fast and accurate temperature measurement, such as measuring human body temperature ...[Details]
introduction
Mobile phones, MP3 players, hard disk players, digital cameras, PDAs and other devices are all controlled by navigation keys. Currently, the more popular navigation key contro...[Details]
Introduction
High voltage power supply is an indispensable part of nuclear radiation detection instrument, which supplies high voltage to nuclear radiation detection devices (such as prop...[Details]
Industrial control
often requires multi-channel fault detection and multi-channel command control (this multi-task setting is very common). A single CPU chip is difficult to directly complete ...[Details]
With the advent of the new economic era represented by the Internet, PCs have lost their former glory, and smart 3C products (Computer, Communication and Consumer) will set off a new wave. As one o...[Details]
0 Introduction
Implantable medical devices can be divided into two types: passive and active. Most passive implantable medical devices are non-electronic products, such as contact lenses, hear...[Details]
Introduction
DFT (Discrete Fourier Transformation) is an important transformation tool for digital signal analysis and processing such as graphics, speech and images.
The amount of calcula...[Details]
High-speed serial communication networks are transmitting data and video information at unprecedented speeds. As transmission speeds increase, the evaluation of networks and their components become...[Details]
1 Introduction
Many test systems require real-time data acquisition while continuously moving. If the test process is discontinuous, or the test position is in front and the acquisition is...[Details]
0 Introduction
μClinux is an operating system for embedded control. It inherits most of the features of the Linux kernel and is designed for embedded microprocessors without a memory manag...[Details]
0 Introduction
With the development of society, people's awareness of medical care is getting stronger and stronger, so the training of doctors has become a very important link. Although m...[Details]
Abstract: This paper describes a design scheme of a tire pressure monitoring system for automobiles that uses a high-performance 8-bit microcontroller MC68HC908RF2 combined with sensors and RF tra...[Details]