ROUND HEAT SINK SPOTLIGHTS

NX300104 Parametric

Parameter NameAttribute value
typeheat sink
Supporting products/related productsspotlight
shaperound
PRODUCT DATASHEET
SynJet Outdoor Spotlight Cooler 60W
SynJet cooling technology provides the most reliable thermal
management solution available. This LED cooler has been developed
by Aavid for cooling downlight and spotlight modules and arrays.
Cools up to 60 W
4
L10 of 100K Hours at 60°C
Energy Efficient
5 Yr Warranty
Small Form Factor
Outdoor Rated
®
Specifications
1
Thermal & Acoustic
SynJet Setting
Mid Performance
Standard Performance
Silent Performance
PWM at 100% duty cycle
Heatsink Only
2
Θs-a
Cu / Al
0.55 / 0.60
0.60 / 0.65
0.70 / 0.75
0.50 / 0.55
1.50 / 1.55
3
TDP (W)
Cu / Al
55 / 50
50 / 46
43 / 40
60 / 55
20 / 19
4
SPL
5
(dBA)
25
22
19
28
N/A
Wire Connections
Red to +VDC
Black & Blue to Ground
Red to +VDC
Black only to Ground
Red to +VDC
Black & Purple to Ground
Red to +VDC
Black only to Ground
Blue to PWM Signal
N/A
N/A
Electrical
SynJet Setting
2
Voltage
(VDC)
+/- 10%
5
Current (mA)
Imin
20
Iavg
120
80
60
160
6
Mid
Standard
Silent
PWM at 100% duty cycle
Ipeak
240
160
120
320
Pavg
(mW)
600
400
300
800
Voltag
e
(VDC)
+/- 10%
12
Current (mA)
Imin
10
Iavg
67
50
40
82
6
Ipeak
134
100
80
164
Pavg
(mW)
800
600
480
980
Environmental
All Settings
Operating Temperature
Storage Temperature
Storage Altitude
Operating Relative Humidity
Weight
Reliability
Regulatory Compliance
1
Min
-40
-50
5
Max
70
85
15K
95
600
100K
Units
C
C
m
%
g
hrs
Conditions
Air temperature surrounding cooler
Air temperature surrounding cooler
Above sea level
Non-condensing
SynJet with Al heat sink and Cu mounting plate
L10 @ 60C
RoHS, UL, FCC Part 15 Class B, CE
All values are typical at 25ºC unless otherwise stated.
The Level Select model should be used for discrete performance settings. Follow the instructions in the Product Design Guide for adjusting settings.
3
Thermal resistance values are given as reference only and are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom
middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at least 15cm
2
using the 60 W reference heat sink. Actual thermal
performance may vary by application and final product design should be tested to assure proper thermal performance.
4
Thermal Design Power is based on a 30ºC temperature rise of heat sink mounting surface above ambient temperature around cooler.
5
Sound Pressure Level is measured at 1 meter distance per ISO 7779.
6
The SynJet has a time varying current. The current waveform is sinusoidal and the average current (Iavg) is used to calculate the average power consumption
(Pavg) at nominal input voltage (VDC). See the Electrical section in the Product Design Guide for a detailed explanation.
2
1 Aavid Circle
Laconia, NH 03246
Phone: 1.855.322.2843
www.aavid.com
MKTG-DOC-000104
Revision
A02
March 2018

NX300104 Related Products

NX300104 NX300103 NX200105 NX200106 NX200107 NX200108
Description ROUND HEAT SINK SPOTLIGHTS ROUND HEAT SINK BRIDGELUX RS ROUND ACTIVE COOLING OUTDOOR MOD ROUND ACTIVE COOLING OUTDOOR MOD ROUND ACTIVE COOLING OUTDOOR MOD ROUND ACTIVE COOLING OUTDOOR MOD
type heat sink heat sink Active cooling Active cooling Active cooling Active cooling
Supporting products/related products spotlight Bridgelux RS Outdoor modules and arrays Outdoor modules and arrays Outdoor modules and arrays Outdoor modules and arrays
shape round round round round round round

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1692  677  2530  2356  2019  35  14  51  48  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号