EEWORLDEEWORLDEEWORLD

Part Number

Search

NX200106

Description
ROUND ACTIVE COOLING OUTDOOR MOD
CategoryLED optoelectronic/LED   
File Size490KB,4 Pages
ManufacturerAavid Thermalloy
Environmental Compliance
Download Datasheet Parametric Compare View All

NX200106 Overview

ROUND ACTIVE COOLING OUTDOOR MOD

NX200106 Parametric

Parameter NameAttribute value
typeActive cooling
Supporting products/related productsOutdoor modules and arrays
shaperound
PRODUCT DATASHEET
SynJet Outdoor Spotlight Cooler 60W
SynJet cooling technology provides the most reliable thermal
management solution available. This LED cooler has been developed
by Aavid for cooling downlight and spotlight modules and arrays.
Cools up to 60 W
4
L10 of 100K Hours at 60°C
Energy Efficient
5 Yr Warranty
Small Form Factor
Outdoor Rated
®
Specifications
1
Thermal & Acoustic
SynJet Setting
Mid Performance
Standard Performance
Silent Performance
PWM at 100% duty cycle
Heatsink Only
2
Θs-a
Cu / Al
0.55 / 0.60
0.60 / 0.65
0.70 / 0.75
0.50 / 0.55
1.50 / 1.55
3
TDP (W)
Cu / Al
55 / 50
50 / 46
43 / 40
60 / 55
20 / 19
4
SPL
5
(dBA)
25
22
19
28
N/A
Wire Connections
Red to +VDC
Black & Blue to Ground
Red to +VDC
Black only to Ground
Red to +VDC
Black & Purple to Ground
Red to +VDC
Black only to Ground
Blue to PWM Signal
N/A
N/A
Electrical
SynJet Setting
2
Voltage
(VDC)
+/- 10%
5
Current (mA)
Imin
20
Iavg
120
80
60
160
6
Mid
Standard
Silent
PWM at 100% duty cycle
Ipeak
240
160
120
320
Pavg
(mW)
600
400
300
800
Voltag
e
(VDC)
+/- 10%
12
Current (mA)
Imin
10
Iavg
67
50
40
82
6
Ipeak
134
100
80
164
Pavg
(mW)
800
600
480
980
Environmental
All Settings
Operating Temperature
Storage Temperature
Storage Altitude
Operating Relative Humidity
Weight
Reliability
Regulatory Compliance
1
Min
-40
-50
5
Max
70
85
15K
95
600
100K
Units
C
C
m
%
g
hrs
Conditions
Air temperature surrounding cooler
Air temperature surrounding cooler
Above sea level
Non-condensing
SynJet with Al heat sink and Cu mounting plate
L10 @ 60C
RoHS, UL, FCC Part 15 Class B, CE
All values are typical at 25ºC unless otherwise stated.
The Level Select model should be used for discrete performance settings. Follow the instructions in the Product Design Guide for adjusting settings.
3
Thermal resistance values are given as reference only and are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom
middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at least 15cm
2
using the 60 W reference heat sink. Actual thermal
performance may vary by application and final product design should be tested to assure proper thermal performance.
4
Thermal Design Power is based on a 30ºC temperature rise of heat sink mounting surface above ambient temperature around cooler.
5
Sound Pressure Level is measured at 1 meter distance per ISO 7779.
6
The SynJet has a time varying current. The current waveform is sinusoidal and the average current (Iavg) is used to calculate the average power consumption
(Pavg) at nominal input voltage (VDC). See the Electrical section in the Product Design Guide for a detailed explanation.
2
1 Aavid Circle
Laconia, NH 03246
Phone: 1.855.322.2843
www.aavid.com
MKTG-DOC-000104
Revision
A02
March 2018

NX200106 Related Products

NX200106 NX300103 NX300104 NX200105 NX200107 NX200108
Description ROUND ACTIVE COOLING OUTDOOR MOD ROUND HEAT SINK BRIDGELUX RS ROUND HEAT SINK SPOTLIGHTS ROUND ACTIVE COOLING OUTDOOR MOD ROUND ACTIVE COOLING OUTDOOR MOD ROUND ACTIVE COOLING OUTDOOR MOD
type Active cooling heat sink heat sink Active cooling Active cooling Active cooling
Supporting products/related products Outdoor modules and arrays Bridgelux RS spotlight Outdoor modules and arrays Outdoor modules and arrays Outdoor modules and arrays
shape round round round round round round
Why does WINCE OS always remind me to set IP after starting the desktop?
My platform is CEPC X86, customized using CEPC BSP that comes with PB4.2, and the system can boot normally. However, when the desktop boots, a dialog box pops up asking me to set DHCP or static IP. Th...
13711088469 Embedded System
51 MCU external interrupt problem
I am a beginner in microcontrollers and there are many things I don't understand. I would like to ask you for advice on how to use external interrupts to light up the LED. In order to achieve the same...
thinking小铺 51mcu
Samsung and Sony reportedly plan to jointly establish a 10th-generation LCD product line
According to Samsung insiders, Samsung and Sony's negotiations on the joint venture to establish a second eighth-generation LCD panel production line have successfully entered the final stage. In addi...
open82977352 Talking
OMAPL138 platform serial port uart0 problem, please help
According to the requirements in DATASHEET, PINMUX3 is configured, i.e. TX and RX, and flow control is disabled. In the system startup information, it shows that the modification is successful, and th...
r16721853 Linux and Android
Wince serial port processing speed problem
Use the serial port to communicate with the MCU, using a baud rate of 57600, 8-bit data, 1 stop bit, and no check bit. The MCU sends a data packet number request command (a total of 10 bytes in length...
卖蛋筒 Embedded System
How to implement fast forward and fast rewind functions
Now we need to use the Waveout function series to play wav files. The playback function has been implemented. Now there is a problem when implementing the fast-forward function. When the fast-forward ...
ywchen03 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1287  231  813  259  2067  26  5  17  6  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号