Note: In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.
ds_61018_0000_en_tk: 110509J
1
TK
TYPES
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
1 Form C
5V DC
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
Single side stable
Part No.
TK1-1.5V
TK1-3V
TK1-4.5V
TK1-5V
TK1-6V
TK1-9V
TK1-12V
TK1-24V
1 coil latching
Part No.
TK1-L-1.5V
TK1-L-3V
TK1-L-4.5V
TK1-L-5V
TK1-L-6V
TK1-L-9V
TK1-L-12V
TK1-L-24V
2 coil latching
Part No.
TK1-L2-1.5V
TK1-L2-3V
TK1-L2-4.5V
TK1-L2-5V
TK1-L2-6V
TK1-L2-9V
TK1-L2-12V
TK1-L2-24V
2) Self-clinching terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
1 Form C
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TK1-H-1.5V
TK1-H-3V
TK1-H-4.5V
TK1-H-5V
TK1-H-6V
TK1-H-9V
TK1-H-12V
TK1-H-24V
1 coil latching
Part No.
TK1-L-H-1.5V
TK1-L-H-3V
TK1-L-H-4.5V
TK1-L-H-5V
TK1-L-H-6V
TK1-L-H-9V
TK1-L-H-12V
TK1-L-H-24V
2 coil latching
Part No.
TK1-L2-H-1.5V
TK1-L2-H-3V
TK1-L2-H-4.5V
TK1-L2-H-5V
TK1-L2-H-6V
TK1-L2-H-9V
TK1-L2-H-12V
TK1-L2-H-24V
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
RATING
1. Coil data
1) Single side stable
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
Pick-up voltage
(at 20°C
68°F)
Drop-out voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
93.8mA
46.7mA
31mA
28.1mA
23.3mA
15.5mA
11.7mA
11.3mA
Coil resistance
[±10%] (at 20°C
68°F)
16Ω
64.3Ω
145Ω
178Ω
257Ω
579Ω
1,028Ω
2,133Ω
270mW
120%V of
nominal voltage
140mW
150%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C
68°F)
2) 1 coil latching
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
Set voltage
(at 20°C
68°F)
Reset voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
66.7mA
33.3mA
22.2mA
20mA
16.7mA
11.1mA
8.3mA
6.3mA
Coil resistance
[±10%] (at 20°C
68°F)
22.5Ω
90Ω
202.5Ω
250Ω
360Ω
810Ω
1,440Ω
3,840Ω
150mW
120%V of
nominal voltage
100mW
150%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C
68°F)
2
ds_61018_0000_en_tk: 110509J
TK
3) 2 coil latching
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
Set voltage
(at 20°C
68°F)
Reset voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
Set coil
133.9mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
20.8mA
16.7mA
Reset coil
133.9mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
20.8mA
16.7mA
Coil resistance
[±10%] (at 20°C
68°F)
Set coil
11.2Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
576Ω
1,440Ω
Reset coil
11.2Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
576Ω
1,440Ω
250mW
400mW
250mW
400mW
120%V of
nominal voltage
110%V of
nominal voltage
200mW
200mW
150%V of
nominal voltage
Nominal operating
power
Set coil
Reset coil
Max. applied voltage
(at 20°C
68°F)
2. Specifications
Characteristics
Arrangement
Contact
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Rating
Max. switching current
Min. switching capacity (Reference value)*
1
Single side stable
Nominal operating
power
1 coil latching
2 coil latching
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Electrical
characteristics
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between open contacts
Between contacts and coil
Item
1 Form C
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Ag+Au clad
2 A 30 V DC (resistive load)
60 W (DC) (resistive load)
220 V DC
2A
10μA 10mV DC
140 mW (1.5 to 12 V DC), 270 mW (24 V DC)
100 mW (1.5 to 12 V DC), 150 mW (24 V DC)
200 mW (1.5 to 9 V DC), 250 mW (12 V DC), 400 mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 V (10×160μs) (FCC Part 68)
2,500 V (2×10μs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 2 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 10
8
(Single side stable), Min. 5×10
7
(1 or 2 coil latching) (at 180 cpm)
Min. 10
5
(2 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to 85°C
–40°F to 185°F*
3
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g
.035 oz.
Specifications
Temperature rise (at 20°C
68°F)
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Shock resistance
Mechanical
characteristics
Vibration resistance
Expected life
Mechanical
Electrical
Conditions for operation, transport and storage*
2
Max. operating speed (at rated load)
Unit weight
Functional
Destructive
Functional
Destructive
Conditions
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in
*3 The maximum ambient temperature allows for coil temperature rise at maximum allowable coil voltage.
As for the applicable range of continuous carrying current against temperature, please refer to “Maximum value of continuous carrying current” chart. (Page 4)
ds_61018_0000_en_tk: 110509J
3
TK
REFERENCE DATA
1. Maximum value of continuous carrying current
Test conditions:
Coil applied voltage: 110% of rated voltage
Continuous carrying current: 1,000 hours
Continuous carrying current, A
3.0
Switching current, A
2. Maximum switching capacity
3. Life curve
100
No. of operations,
×10
4
2
2.0
DC load
1.0
30 V DC resistive
10
1
0.5
0.4
0.3
0.2
0
40
50
60
70
80 85 90
Ambient temperature,
°C
20 30
50
100
200 300
Switching voltage, V
0
1
2
Switching current, A
4. Mechanical life
Tested sample: TK1-12V, 8 pcs.
Switching frequency: 30 Hz
100
Ratio against the rated voltage, %V
90
80
70
60
50
40
30
20
10
0
10
Drop-out voltage
Max.
Min.
100
1,000
10,000
No. of operations,
×10
4
Min.
Pick-up voltage
Max.
5. Electrical life (DC load)
Tested sample: TK1-12V, 10 pcs.
Condition: 2 A 30 V DC resistive load, 20 cpm
Change of pick-up and drop-out voltage
Ratio against the rated voltage, %V
100
90
80
70
60
50
40
30
20
10
0
No. of operations,
×10
4
Change of contact resistance
100
90
80
70
60
50
40
30
20
Max.
Min.
Pick-up voltage
Max.
Min.
Drop-out voltage
Max.
Min.
10
Contact resistance, mΩ
10
0
No . of operations,
×10
4
10
6.-(1) Coil temperature rise
Tested sample: TK1-12V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 25°C
77°F
Room temperature
0A
60
1A
2A
50
40
30
20
10
0
6.-(2) Coil temperature rise
Tested sample: TK1-12V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
70°C
Temperature rise,
°C
60
50
40
30
20
10
0
0A
1A
2A
Temperature rise,
°C
80 90 100 110 120 130 140 150
Coil applied voltage, %V
80 90 100 110 120 130 140 150
Coil applied voltage, %V
7.-(1) Operate/release time characteristics
Tested sample: TK1-5 V, 50 pcs.
7.-(2) Operate/release time characteristics
Tested sample: TK1-5 V, 50 pcs.
8. Ambient temperature characteristics
Tested sample: TK1-12V, 5 pcs.
Variation ratio, %
40
30
20
10
20 40
60
Drop-out
voltage
−
x
−
x
Pick-up
voltage
<Without diode>
<With diode>
Operate/release time, ms
4
Operate/release time, ms
4
3
3
–40 –20
2
Release time
Max.
Max.
Min.
Min.
Operate time
80
90
100 110 120
Coil applied voltage, %V
0
0
80
Ambient
–10 temperature,
°C
–20
–30
–40
2
Operate time
Max.
Max.
Min.
Min.
1
Release time
0
80
1
90
100 110 120
Coil applied voltage, %V
0
4
ds_61018_0000_en_tk: 110509J
TK
9.-(1) High-frequency characteristics
(Isolation)
9.-(2) High-frequency characteristics (Insertion
loss)
1.8
1.6
1.4
Z
Y
,
Y
,Z XX
10. Malfunctional shock
Tested sample: TK1-12V, 6 pcs. (single side stable);
[font=宋体]The stepper motor is a fully digital electric actuator. In principle, its angular displacement is proportional to the number of driving pulses. Under normal circumstances, the stepper motor h...
Today I took a quick look at the OPEN1081 tick documentation and found the following explanation:The system systick has been used as the time base of the wifi protocol stack, with a timing of 1ms, so ...
Log-Periodic Antenna
The purpose of log-periodic antenna is nothing more than communication transmission, receiving and transmitting communication signals. However, there are many types of communicati...
The last trial period is coming. I have also debugged the USB library function in the past two days. On the eeworld forum, the posts of moderator Xiaochuan accompanied me through this week. Now I will...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
1. Introduction
This design was made for participating in an electronic design competition. It effectively solved the problem of the operation and control of an electric car on a seesaw. The s...[Details]
With the advent of increasingly powerful processors, image sensors, memory, and other semiconductor devices, as well as the algorithms that enable them, computer vision can be implemented in a wide...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
On the afternoon of July 10, Beijing time, Taiwan's largest chip designer MediaTek expects its smartphone chip shipments to grow by double digits in the third quarter of this year, and the company is ...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
As people's requirements for safety and comfort in the process of driving cars continue to increase, automotive radars are widely used in the car's adaptive cruise system, collision avoidance syste...[Details]