EEWORLDEEWORLDEEWORLD

Part Number

Search

PM2260A25VJH

Description
Solid State Relay,
CategoryLED optoelectronic/LED    photoelectric   
File Size493KB,7 Pages
ManufacturerSensata
Environmental Compliance
Download Datasheet Parametric View All

PM2260A25VJH Online Shopping

Suppliers Part Number Price MOQ In stock  
PM2260A25VJH - - View Buy Now

PM2260A25VJH Overview

Solid State Relay,

PM2260A25VJH Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145128715304
Reach Compliance Codeunknown
DataSheet
Panel Mount
PM22 Series
Output ratings up to 95 Amps at 600VAC
Built-in overvoltage protection
DBC substrate for superior thermal performance
LED input status indicator
IP20 touch-safe housing
AC or DC control
4000 VAC optical isolation
C-UL-US and TUV approved
Panel Mount SSRs
PRODUCT SELECTION
Control Voltage
90-280 VAC/VDC
4-32 VDC
25A
PM2260A25V
PM2260D25V
50A
PM2260A50V
PM2260D50V
95A
PM2260A95V
PM2260D95V
AVAILABLE OPTIONS
Operating Voltage
60:
48-600 VAC
Rated Load Current
25:
25 Amps
50:
50 Amps
95:
95 Amps [High I
2
t]
Switching Type
Blank:
Zero Voltage
Turn-On
Thermal Pad
R:
Instantaneous Turn-On
Blank:
Not Included
(Motor Rating Certified)
H:
Included
Series
PM22
Required for valid part number
For options only and not required for valid part number
60
A
25
U
V
R
J
H
U
Control Voltage
(1)
A:
90-280 VAC/VDC
D:
4-32 VDC
Terminal Layout
Input Connector
V:
Contactor Configuration
Blank:
Screw Terminal
J:
Spring Terminal
OUTPUT SPECIFICATIONS
(2)
Description
Operating Voltage (47-440Hz) [V
RMS
]
Transient Overvoltage [Vpk]
(3)
Maximum Off-State Leakage Current @ Rated Voltage [mA
RMS
]
Minimum Off-State dV/dt @ Maximum Rated Voltage [V/ sec]
Load Current, General Use UL508/LC A IEC 62314 @ 40°C [A
RMS
]
(4)
Load Current, Motor Starting UL508 FLA/LC B IEC 62314 @ 40°C [A
RMS
]
(4)
Minimum Load Current [mA
RMS
]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Juntion to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Heat Sink for Rated Current @ 40ºC [°C/W]
Minimum Power Factor (at Maximum Load)
Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC
25A
48-600
1200
1
500
25
8.5/4.8
100
286/300
1.35
0.49
409/375
2
0.5
0.5 (0.37)
1.5 (1.1)
3 (2.24)
50A
48-600
1200
1
500
50
14/7.6
100
716/750
1.35
0.27
2563/2343
0.7
0.5
1 (0.74)
3 (2.2)
5 (3.7)
95A
48-600
1200
1
500
95
26/14
150
1290/1350
1.30
0.2
8320/7593
0.23
0.5
2 (1.5)
5 (3.73)
10 (7.4)
INPUT SPECIFICATIONS
(2)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
PM2260DxxV
4-32 VDC
(5)
-32 VDC
4 VDC
1 VDC
10 mA
15 mA
Current Limited
1/2 Cycle
(7)
1/2 Cycle
PM2260AxxV
90-280 VAC/VDC
(6)
-
90 VAC/VDC
5 VAC/VDC
6 mA
10 mA
Current Limited
20
30
Do not forget to visit us at:
www.crydom.com
Copyright © 2015 Crydom Inc. Specifications subject to change without notice.
3.3V to 5V, what chips do you use in practice?
3.3V to 5V, what chips do you use in practice?...
安_然 Analog electronics
It runs fine in IAR, but when I switch to MDK, it will inexplicably enter a fault interrupt. Please help me!
The following program works fine in IAR, but I am a bit picky and I am used to using MDK, so I switched to MDK. I kept the program the same, but replaced the corresponding driverlab.a file with the co...
cjqhyy Microcontroller MCU
Stack overflow occurs after WinCE R2 patch 081231
Hello, my WINCE6.0 is upgraded to R2 version and everything runs normally. When I installed the patch 081231, a stack overflow occurred. The debugging information is as follows: OEMLaunch: Physical Ad...
10082888 Embedded System
Maybe it's stupid, but I really don't understand the question about IS PS DS of 2407
Regarding the data space address space IO space and DS PS IS of 2407, please give me some advice 1. When do the three feet of IS, PS and DS become low? 2. For example, if I expand three RAMs, they are...
fgxl1983 Microcontroller MCU
Transform AT power supply into adjustable voltage regulated power supply
1: First remove the rectifier diodes at the 5V output terminals (keep the 12V rectifier diodes), replace the filter capacitor at 12V, and refer to the above figure to remove the following components D...
qwqwqw2088 Analogue and Mixed Signal
IoT Smart Home System
[i=s]This post was last edited by Xiao Feng Chui Yi on 2022-10-23 08:58[/i]1. Introduction of the work (100-200 words) The name of this work is the Internet of Things Smart Home System. The host and s...
萧风吹衣 DigiKey Technology Zone

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 856  1430  491  360  2887  18  29  10  8  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号