Description
CAP CER 200PF 100V 5% BP 1206
CategoryPassive components   
File Size235KB,37 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

CDR32BP201BJZPAT Overview

CAP CER 200PF 100V 5% BP 1206

CDR32BP201BJZPAT Parametric

Parameter NameAttribute value
capacitance200pF
Tolerance±5%
Voltage - Rated100V
Temperature CoefficientBP
Operating temperature-55°C ~ 125°C
characteristic-
grade-
applicationUniversal
failure rateP(0.1%)
Installation typeSurface mount, MLCC
Package/casing1206 (3216 metric)
size/dimensions0.126" long x 0.063" wide (3.20mm x 1.60mm)
Height - Installation (maximum)-
Thickness (maximum)0.051"(1.30mm)
lead spacing-
Lead form-
notifyQPL or military specifications are for reference only. Non-military parts. See terms and conditions.
CDR-MIL-PRF-55681
www.vishay.com
Vishay Vitramon
Surface Mount Multilayer Ceramic Chip Capacitors
MIL Qualified, Type CDR
FEATURES
• Military qualified products
• Federal stock control number,
CAGE CODE 2770A
• High reliability tested per MIL-PRF-55681
• Tin / lead termination codes “W”, “Z”, and “U”
• Lead (Pb)-free termination codes “Y” and “M”
• Wet build process
• Reliable Noble Metal Electrode (NME) system
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details
Available
Available
APPLICATIONS
• Avionic systems
• Sonar systems
• Satellite systems
• Missiles applications
• Geographical information systems
• Global positioning systems
ELECTRICAL SPECIFICATIONS
Note
Electrical characteristics at +25 °C unless otherwise specified
Operating Temperature:
-55 °C to +125 °C
Capacitance Range:
1.0 pF to 470 nF
Voltage Range:
6.3 V
DC
to 100 V
DC
Temperature Coefficient of Capacitance (TCC):
BP: 0 ppm/°C ± 30 ppm/°C from -55 °C to +125 °C,
with 0 V
DC
applied
0 ppm/°C ± 30 ppm/°C from -55 °C to +125 °C,
with 100 % rated V
DC
applied
BX: ± 15 % from -55 °C to +125 °C, with 0 V
DC
applied
BX: +15 %, -25 % from -55 °C to +125 °C,
with 100 % rated V
DC
applied
BR: ± 15 % from -55 °C to +125 °C,
with 0 V
DC
applied
+15 %, -40 % -55 °C to +125 °C,
with 100 % rated V
DC
applied
Dissipation Factor (DF):
BP: 0.15 % maximum
BX: 2.50 % maximum
BR:
25 V: 3.5 % maximum
> 25 V: 2.5 % maximum
Test frequency:
1 MHz ± 50 kHz for BP capacitors
1000 pF
and for BX capacitors
100 pF
All other BP, BX, and BR at 1 kHz ± 50 Hz
Aging Rate:
BP: 0 % maximum per decade
BX, BR: 1 % maximum per decade
Insulation Resistance (IR):
at +25 °C and rated voltage 100 000 M minimum or
1000
F,
whichever is less
Dielectric Strength Test:
performed per method 103 of EIA-198-2-E.
Applied test voltages:
100 V
DC
-rated: 250 % of rated voltage
Revision: 14-May-2018
Document Number: 45026
1
For technical questions, contact:
mlcc@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Network remote control
Hey guys, I recently read an article in this forum called "Network Development Notes: Controls and Controls", which said: "1. Introduction There are three functions in HTTP_CGI.c, all of which are use...
ZHANGXUEJIE Microcontroller MCU
Review of UCOSIII
I have been using the UCOS system for some time, and I have compiled a report mainly from the application perspective. Work to be prepared when creating a task: //Task priority #define START_TASK_PRIO...
ywlzh MCU
FPGA+Dual DDR2 Core Board User Manual
...
chenzhufly FPGA/CPLD
Jobs after graduation
I am currently working in a small company, and I am responsible for the communication algorithms of STM32 and FPGA. They are also responsible for the hardware platform, monitoring driver and other thi...
乱起东城 Talking about work
Which software version is better for drawing board?
I have always used AD to draw boards and have never used PADS software. Recently, I took a second-hand job and the people there used PADS. I had no choice but to learn PADS. I would like to ask you wh...
bigbat PCB Design
EEWORLD University ---- Fuse types and tests
Fuse types and tests : https://training.eeworld.com.cn/course/5155...
抛砖引玉 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 219  207  2377  2552  2235  5  48  52  46  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号