RP
RP185 Series
RP185
IEC INLET TO 15A
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
High Performance IEC Inlet Single Stage Power Line Filter
SPECIFICATIONS
Operating Freq.
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Plastic Mtg Force
Terminals (-T)
Safety Approvals
Typ. Weight, LBS (KG)
:
:
:
:
:
:
:
:
:
50/60Hz
250V +10%
-25 to 40C
25/100/21
2121VDC
18 LBS
QD: 0.25 Tabs
CSA, UR, EN60939
0.2 (0.1)
0
LEAKAGE CURRENT
Y-cap, nF
.47
1
2.2
4.7
mA,
120V/60Hz
0
0.04
0.09
0.2
0.4
mA,
250V/60Hz
0
0.08
0.18
0.4
0.8
SCHEMATIC
PART NUMBER/ ORDERING
RP185
-X
(Amps)
1
3
6
10
15
-Y
(Ycap, nF)
0
.47
1
2.2
4.7
-T
QD
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP185-15-.47-QD (15Amps with .47nF Ycap)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
45
RP
RP185
Typical Insertion Loss, dB (50/50ohm)
1 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
46
22
.5
55
38
1.0
55
60
10
55
60
30
50
50
RADIUS POWER
Your Power Partner
Mechanical Dimensions
3 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
36
22
.5
50
35
1.0
55
50
10
55
60
30
50
60
6 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
22
20
.5
35
32
1.0
42
40
10
55
50
30
60
55
10 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
20
20
.5
32
32
1.0
28
40
10
55
58
30
55
60
TYPICAL TOLERANCE: +/-0.02 (0.50)
15 Amp
FREQ (MHz)
CM(dB)
DM(dB)
.15
14
15
.5
22
32
1.0
30
40
10
50
54
30
58
70
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com