EEWORLDEEWORLDEEWORLD

Part Number

Search

PX3AN2BH150PSAAX

Description
Industrial pressure sensor PX3 PRESSURE SENSOR
CategoryThe sensor    Pressure sensor    Industrial pressure sensor   
File Size2MB,10 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

PX3AN2BH150PSAAX Online Shopping

Suppliers Part Number Price MOQ In stock  
PX3AN2BH150PSAAX - - View Buy Now

PX3AN2BH150PSAAX Overview

Industrial pressure sensor PX3 PRESSURE SENSOR

PX3AN2BH150PSAAX Parametric

Parameter NameAttribute value
MakerHoneywell
Product CategoryIndustrial pressure sensor
productTransducers
work pressure100 psi
pressure typeSealed Gauge
accuracy0.25 %
Output typeAnalog
port size1/8-27 NPT
Installation stylePanel
The output voltage0.5 V to 4.5 V
Working power voltage5 V
pressure portPort
seriesPX3
IP ratingIP67
Maximum operating temperature+ 125 C
Minimum operating temperature- 40 C
Working power current3 mA
Factory packaging quantity60
Supply voltage - max.5.5 V
Supply voltage - min.4.5 V
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
32313757
Datasheet
Issue E
Figure 2. PX3 Series External Freeze/Thaw Resistance
(Shown with mating connector, see Figure 5.)
• Reduced current consumption: Helps to reduce energy costs,
and enhances product life if used in battery driven systems.
• Media compatibility: Common HFC (hydrofluorocarbon)
refrigerants (R410A and R134A), next generation low
global warming potential (GWP) refrigerants (R448A/
Solstice
®
N40, R32 and R1234ZE), engine oil, petroleum-
based hydraulic fluids, brake fluids (DOT3), and dry air. For
ammonia and other corrosive media, see Honeywell’s SPT Series.
DIFFERENTIATION
• Optional diagnostics mode: Beneficial in applications where
the sensor functionality and the need to know internal or
external failure modes is critical.
• Great customer value: Multiple configuration possibilities
provide flexibility of use in the application with no upfront
NRE or tooling charges.
• Durable: Provides the tough environmental specifications
needed, including insulation resistance and dielectric
strength, external freeze-thaw resistance (see Figure 2),
and EMC performance.
• 4 mA to 20 mA output is temperature compensated up to 125°C.
FEATURES
• Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute
and sealed gage)
• Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc
• 4 mA to 20 mA output supports transmission of output
signals over longer distances
• Calibrated and temperature compensated
• Total Error Band: ±1.0 %FSS from -20°C to 85°C [-4°F to 185°F]
• External freeze/thaw resistance: 6 cycles from -30°C to
50°C [-22°F to 122°F]
• Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non-
ionized air)
• Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non-
ionized air)
• Current consumption: 3.5 mA max.
• EMC (radiated immunity): 200 V/m (ratiometric voltage
output), 140 V/m (current output) per ISO 11452-2
• Ingress protection IP67 (Metri-Pack connector), IP69K
(cable harness), IP65 (DIN connector)
• RoHS, REACH, and CE compliant
• Six industry-standard pressure port types, including a tube port
which provides for hermetically-sealed process connection
POTENTIAL APPLICATIONS
• Industrial: Refrigerant pressure monitoring in HVAC/R
systems; dry air system pressure, process controls and
automation
• Transportation: Dry air system monitoring; hydraulic, brake,
and engine oil fluid pressure monitoring; air brake pressure
monitoring
The PX3 Series is not recommended for use with media
involving water, saturated air such as steam and vapor, and
ammonia.
PORTFOLIO
Honeywell’s PX3 Series joins the PX2 Series, MLH Series, and
SPT Series heavy duty pressure transducers.
DESCRIPTION
Honeywell’s PX3 Series Heavy Duty Pressure Transducers
use piezoresistive sensing technology with ASIC (Application
Specific Integrated Circuit) signal conditioning in a brass
housing and Metri-Pack 150, DIN, or cable harness electrical
connections. The PX3 Series is calibrated and temperature
compensated from -40°C to 125°C [-40°F to 257°F].
VALUE TO CUSTOMERS
• Total Error Band (TEB) ±1.0 %FSS from -20°C to 85°C:
Provides indication of the sensor’s true measurement
performance over a specified temperature range; small
error promotes system uptime and efficiency. (See Figure 1.)
Figure 1. TEB Definition and Temperature Performance
Sources of Error
Offset
Full Scale Span
Pressure Non-Linearity
Pressure Hysteresis
Pressure Non-Repeatability
Thermal Effect on Offset
Thermal Effect on Span
Thermal Hysteresis
Total Error Band (%FSS)
3
2
1
0
-1
-2
-3
-40°C
[-40°F]
-20°C
[-4°F]
0°C
[32°F]
Accuracy
BFSL
Total
Error
Band
Total Error Band
Temperature (°C [°F])
85°C
[185°F]
125°C
[257°F]
• Higher insulation resistance and dielectric strength:
Protects the user and sensor in high over-voltage
situations, and ensures that the device is compliant with
industry standards.
• Higher EMC performance: Operates more reliably in the
presence of electro-magnetic fields, such as near wireless
signals, RF communication, and electrical devices.
• Higher external freeze/thaw resistance: Survives exposure to
frost, commonly found in refrigeration systems. (See Figure 2.)
Sensing and Internet of Things
C2000 section participates in TI DIY CNC power supply activity to call for volunteers
The participants in this section are responsible for the writing of the C2000 software . Currently, the project team has preliminarily decided to use 28035 .The preliminary plan is shown in the figure...
安_然 Microcontroller MCU
Deep understanding of DSP
1. The selection of TI DSP mainly considers processing speed, power consumption, capacity of program memory and data memory, and on-chip resources, such as the number of timers, number of I/O ports, n...
glorey Embedded System
[ATmega4809 Curiosity Nano Review] Installing MCC
As the functions of microcontrollers increase, their use becomes more and more complicated. If you use the traditional development method, you need to understand various registers before you can use t...
dcexpert MCU
EE V7.9.5 export ASCII problem
[size=14px]I installed ee v7.9.5, but there is no ASCII export option in file--export. Can you help me solve this problem? Is there a problem with the cracked installation or do I need to install some...
两只岸上的鱼 PCB Design
When programming CAN communication with DSP, is it better to use interrupt mode or polling mode when receiving mailboxes?
I would like to ask the experts for advice. When writing a CAN communication program for the lower computer using dsp28335, there are many nodes on the bus and the amount of communication data is larg...
zhbcug TI Technology Forum
GD32E231C-START Unboxing
The GD32E231C-START board is very good in appearance design. It is similar to STM32's NUCLEO, but more beautiful than NUCLEO, the color is whiter, and the black silk screen looks more comfortable. The...
littleshrimp GD32 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 454  1092  2045  1430  1028  10  22  42  29  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号