BBS-1/2

Description
Industrial & Electrical Fuse 600V 10kA .5A Fast Acting Ferrule
CategoryCircuit protection    The fuse    Industrial and electrical fuse   
File Size173KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric View All

BBS-1/2 Overview

Industrial & Electrical Fuse 600V 10kA .5A Fast Acting Ferrule

BBS-1/2 Parametric

Parameter NameAttribute value
MakerBussmann (Eaton)
Product CategoryIndustrial and electrical fuses
Shipping restrictionsMouser does not currently sell this product.
RoHSN
seriesBBS
productMidget Fuse
Current rating500 mA
Voltage ratingAC600 VAC
Fuse typeFast Blow
interrupt rating10 kA
Subject typeCartridge Fuses
Installation styleHolder
Termination typeClip
Fuse size/group5AG Midget (10.3 mm x 38.1 mm)
Indicator typeWithout Indicator
EncapsulationBulk
diameter0.41 in
length1.38 in
typeFerrule Fuse, Fibre Material
Factory packaging quantity10
unit weight5.897 g
Technical Data 2010
Effective December 2015
Supersedes April 2014
BUSSMANN
SERIES
BBS 13⁄32˝ x 1-3/8˝ 600Vac fast-acting
supplemental fuses
Catalog symbol / color code:
Carton quantity
Amps
1/10 to 30
Qty.
10
BBS
Black (600Vac max, 1/10 to 6A)
Green (250Vac max, 7 to 10A)
Purple (48Vac max, 12 to 30A)
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends
upgrading to Bussmann series Low-Peak™
Class CC fuses. See data sheet No.1023.
Dimensions - in:
0.41"
(±0.004)
1.38"
(±0.031)
Specifications:
600Vac
1/10 to 6A
Features:
Ratings
Interrupting rating at
system voltage
Fuse amp
range
600
Vac
250
Vac
48
Vac
Agency
information
UL
®
CSA
®
Color coded for 600Vac (black) 250Vac
(green) and 48Vac (purple) for maximum
voltage ratings
Fiber tube construction
Nickel-plated endcaps.
1/10 to 6 10kA
7 to 10
12 to 30* –
10kA
X
X
X
X
-
Typical applications
Control circuits
Gaseous vapor fixtures
HID ballasts
Electronic circuits
Hand-held meters
* For interrupting rating, contact factory.
Agency information
CE
UL Listed, Std. 248-14 (1/10-6A@600Vac,
7-10A@250Vac), Guide JDYX, File E19180
CSA Certified, C22.2 No. 248.14
(1/10-6A@600Vac, 7-10A@250Vac),
Class 1422-01, File 53787
250Vac
7 to 10A
Recommended fuse blocks/fuse
holders:
Catalog
symbol
BMM
Description
Blocks
1-, 2- and 3-pole
modular blocks with
optional covers
1-, 2- and 3-pole
3-pole protection
module
3-pole holder
3-pole holder +
switch
1-pole holder
1-pole holder
1-pole holder
Data sheet
No.
10235
Catalog n
um
bers (amps)
BBS-1/10
BBS-2/10
BBS-1/4
BBS-4/10
BBS-1/2
BBS-6/10
BBS-3/4
BBS-8/10
BBS-1
BBS-1-1/2
BBS-1-6/10
BBS-1-8/10
BBS-2
BBS-3
BBS-4
BBS-5
BBS-6
BBS-7
BBS-8
BBS-10
BBS-12
BBS-15
BBS-20
BBS-25
BBS-30
DIN-Rail holders / switches
CHM
Optima NG
Optima
Optima
3185
1109
1102
1103
48Vac
12 to 30A
Panel mount holders
HPF-L
HPS-L
In-line
HEH
Fuseclips
1A3400, 5956
and 5960
Fuse covers
CVR(I)-CCM(-QC)
Finger-safe fuse cover 10235
PCB fuseclips
2132
2124
2114
2113
Small power switching power supply design practice
This chapter takes the design of a practical small power supply as an example to illustrate the method of power supply design. The control circuit is in the form of self-excitation, and UC3842 is used...
木犯001号 Power technology
Does TI have any energy harvesting solutions? Solar energy, piezoelectric vibration, temperature difference.
Does TI have any energy harvesting solutions? Solar energy, piezoelectric vibration, temperature difference. Lingte has a series of Energy Harvesting, all of which are in use. I also want to know if T...
dingshidong TI Technology Forum
89C51
[i=s]This post was last edited by paulhyde on 2014-9-15 09:33[/i] 89C51FDBDFBDGD...
sunweioook Electronics Design Contest
Three-axis gyroscope, acceleration sensor, geomagnetic sensor
Each small circuit board is a sensor, which can be combined flexibly. It adopts a 4-layer gold-plated design. They are: 1. Three-axis gyroscope mpu3050. 2. Three-axis geomagnetic sensor MAG3110, MMC32...
zhenleichen Microcontroller MCU
Is there anyone who uses TVP5147 as a decoding chip? The effect of my configuration is very bad, how can I improve it? ! Does anyone have the optimized parameter table?
Is there anyone who uses TVP5147 as a decoding chip? The effect of my configuration is very bad, how can I improve it? ! Does anyone have the optimized parameter table?...
dreamwalk Embedded System
Problems with vxworks source code and tornado's target directory
I just started using vxworks and am now learning about END drivers. I saw a file called templateEnd.c in the src file under the target directory of tornado. I don't quite understand the relationship b...
zhouliyong11 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 976  2142  1348  746  570  20  44  28  16  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号