EEWORLDEEWORLDEEWORLD

Part Number

Search

482-G212-K1M1-F6S0-7.5A

Description
Thermal circuit breaker with threadneck mounting and push-pull operation
CategoryCircuit protection    Circuit protection   
File Size272KB,5 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric Compare View All

482-G212-K1M1-F6S0-7.5A Overview

Thermal circuit breaker with threadneck mounting and push-pull operation

482-G212-K1M1-F6S0-7.5A Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerE-T-A [E-T-A Circuit Breakers]
Reach Compliance Codecompliant
Circuit protection typeTHERMAL CIRCUIT BREAKER
High Performance Thermal Circuit Breaker 482-...
Description
Single pole compact high performance thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band
on the push button clearly shows the tripped/off position. Threadneck
panel mounted in tracked vehicle and aircraft/general purpose versions,
with optional auxiliary contacts.
Typical applications
Extra low voltage wiring systems on all types of vehicles for land, sea
and air, battery powered machines, process control.
without aux. contacts
482
1
with aux. contacts
Ordering information
Type No.
482
single pole thermal circuit breaker
Mounting
G
threadneck panel mounting
Threadneck design
1
M 12x1 nickel plated
2
M 12x1 black
Hardware - washer for threadneck
0
without hardware
1
corrugated washer 12/15, fitted
Hardware - hex nut for threadneck
0
without hardware
1
hex nut M12x1 nickel plated
2
hex nut M12x1 black
Terminal design (main terminals)
K1
screw terminals with metric thread M4
Characteristic curve
M1
thermal 1.15-1.4 I
N
Terminal screws
A
flat head screw M4x6, ISO 1580, fitted
F
Phillips screw M4x6 (ISO 7045), bulk shipped
Z
without
Terminal washers
0
without lock washer
1
lock washer DIN 137-B4, fitted
6
lock washer DIN 137-B4, bulk shipped
Auxiliary contact
S0
without auxiliary contacts
S1
with auxiliary contact (NC)
Current ratings
0.1...50 A
482 - G 1 1 1 - K1 M1 - A 1
S1 - 10 A
ordering example
Technical data
Voltage rating
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
main to aux. circuit
Insulation resistance
Interrupting capacity I
cn
AC 115 V (400 Hz); DC 28 V
AC 230 (50/60 Hz) to special order
0.1...50 A
0.5 A, DC 28 V
10,000 operations mechanical
5,000 operations at I
N
-55...+75 °C (-67...+167 °F)
rated impulse
pollution
withstand voltage
degree
1.5 kV
3
test voltage
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2.5 A 15 x I
N
3...3.5 A
250 A DC / 150 A AC
4...7 A
500 A
7.5...50 A
6,000 A DC / 1,000 A AC
35...50 A
with auxiliary contact:
3,000 A DC / 1,000 A AC
I
N
U
N
0.1...50 A
DC 72 V
5,000 A
operating area IP40
terminal area IP00
10 g (55-2000 Hz), ± 0.76 mm (10-55 Hz)
to VG 95210, sheet 19/IEC 60068-2-6, test Fc
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050
Vibration
Shock
50 g (11 ms)
to VG 95210, sheet 28/IEC 60068-2-27, test Ea
Preferred types
Preferred types
482-G111-K1M1-A1S0-
482-G212-K1M1-A1S0-
Standard current ratings (A)
1 3 5 6 8 10 15 20 25 30 35 40 50
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Corrosion
Humidity
Explosion
Mass
48 hours at 5 % salt mist
to VG 95210, sheet 2/IEC 60068-2-11, test Ka
240 hours at 95 % RH
to VG 95210, sheet 7/IEC 60068-2-3, test C
to VG 95210, sheet 10/MIL-STD-202,
meth. 109
approx. 43 g without auxiliary contact
approx. 46 g with auxiliary contact
Approvals
Authority
UL
CSA
Bw
Standard
UL 1077
C22.2 No 235
VG 95345,
part 21
Rated voltage
DC 72 V
DC 72 V
DC 28 V
Current ratings
0.1 A…50 A
0.1 A…50 A
0.5 A…50 A
Previous ordering codes:
482-N-MS = 482-G111-K1M1-A1S0-...A
482-MS
= 482-G212-K1M1-A1S0-...A
1646
www.e-t-a.de
1

482-G212-K1M1-F6S0-7.5A Related Products

482-G212-K1M1-F6S0-7.5A 482-G212-K1M1-A1S0-7.5A
Description Thermal circuit breaker with threadneck mounting and push-pull operation Thermal circuit breaker with threadneck mounting and push-pull operation
Is it lead-free? Lead free Lead free
Maker E-T-A [E-T-A Circuit Breakers] E-T-A [E-T-A Circuit Breakers]
Reach Compliance Code compliant compliant
Circuit protection type THERMAL CIRCUIT BREAKER THERMAL CIRCUIT BREAKER

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 980  1907  583  898  1904  20  39  12  19  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号