3-104-206

Description
AC power input module 8A C14 2P APPL INLET SCREW ON MOUNTING
CategoryThe connector    The connector   
File Size854KB,9 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

3-104-206 Online Shopping

Suppliers Part Number Price MOQ In stock  
3-104-206 - - View Buy Now

3-104-206 Overview

AC power input module 8A C14 2P APPL INLET SCREW ON MOUNTING

3-104-206 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codeunknown
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
DD14
IEC Appliance Inlet C14 with Filter 2-Stages, Fuseholder 1- or 2-pole, Line Switch 2-pole
Screw-on mounting horizontal (version B)
Order required accessories separately
Screw-on mounting vertical (version A)
Snap-in mounting
C14
See below:
70° C
Approvals and Compliances
Description
Characteristics
- Panel mount :
Snap-in or screw-on mounting from front side
- 4 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 1- or 2-pole , 2-Stages line filter in standard and
medical version
- V-Lock notch standard
- Quick connect terminals 6.3 x 0.8 mm
- Ultra-compact design. Ideal for low profile designs
Aluminum case provides good shielding
- All single elements are already wired
- Fuse drawer meets requirements of medical standard IEC/EN 60601-1
- Ideal for application with high transient loads
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
-
-
-
-
-
-
-
-
Unique Selling Proposition
-
-
-
-
Most compact power entry module with 2-stages filter
Attractive flat design
Various mounting options
V-Lock cord retaining
Solder terminals
Fuse drawer 1-pole, plus spare fuse case
Fuse drawer 2-pole, with shorting bar
Other rocker marking
Line switch, illuminated
Line switch 1-pole
Medical version M80
Class X1- and Y1-capacitors for enhanced withstand voltage
References
Weblinks
Alternative: version without line filter
DD11
Alternative: version with 1-stage filter
DD12
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Landing Page
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on mounting: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in version: 1 mm - 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'000'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
Material: Housing
MTBF
Approvals and Compliances
EMC Products
1
How does this function eliminate key jitter?
The following is the scan debounce function: void keyscan() { if(s2==0) //S2 is an independent key { while(s2==0); //I want to ask why if S2 is pressed and not released, NUM should be increasing all t...
16816 51mcu
[TI millimeter wave radar evaluation]_4_boost board evaluation encountered problems 2
[i=s]This post was last edited by wangran_95 on 2019-12-31 08:47[/i]After using the device, I found that it was hard to find a power supply. There were two boards and two power supplies, so I had to c...
wangran_95 TI Technology Forum
【FPGA(cyclone4) Issue 2】 Timing and Simulation Learning - Traditional Divider
[color=#000][font=Tahoma][size=3][b]The concept of traditional division is the same as that of traditional multiplication. Multiplication is an accumulation process, while division is a decremental pr...
wsdymg FPGA/CPLD
Ask a weak question
When using MAX232 to make an RS232 interface, is it necessary to use the RX and TX pins of the 51 microcontroller? Can other pins be used?...
yanxinghua Embedded System
IC41C16256-25K Function Tester
Hello: Simple operation can determine whether the chip is good or bad! IC41C16256-25K functional tester is the latest dedicated chip tester launched by CECCLab. It has the characteristics of simple op...
cecc-2010 Power technology
About GPS data receiving and 51 control serial port sending problem!!
Hello everyone!! I haven't been to the forum for a long time, I miss you all, hehe! My song ordering system is dead. I really can't figure out how to use time-sharing multiplexing. Oh! But I still wan...
51学习者 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1086  975  2603  848  906  22  20  53  18  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号