EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/GBB-5-R

Description
Fuse tubeCERAMIC VERY FAST ACTING
CategoryCircuit protection    The fuse    The fuse tube   
File Size218KB,2 Pages
ManufacturerBussmann (Eaton)
Environmental Compliance
Download Datasheet Parametric View All

BK/GBB-5-R Overview

Fuse tubeCERAMIC VERY FAST ACTING

BK/GBB-5-R Parametric

Parameter NameAttribute value
MakerBussmann (Eaton)
Product Categoryfuse tube
Shipping restrictionsMouser does not currently sell this product.
seriesGBB
productCeramic Fuse
Current rating5 A
Fuse typeFast Blow
Fuse size/group3AB (6.3 mm x 32 mm)
Voltage ratingAC250 VAC
Voltage ratingDC125 VDC
interrupt rating200 A
Installation styleHolder / Clip
Termination typeClip
EncapsulationBulk
resistance21.25 mOhms
Subject typeCylindrical
diameter6.35 mm
Indicator typeWithout Indicator
length31.75 mm
Factory packaging quantity100
unit weight2.635 g
Technical Data
2013
Effective
May
2017
Supersedes
July
2009
GBB
1⁄4" x 1 1⁄4" Very-fast acting ceramic tube fuses
Agency information
UL Recognized Card: 1-30A (JFHR2, E56412)
CSA Component Accepted Card: 1-30A
(Class 1422-30 File 53787)
Ordering
Specify packaging, product, and option code
Product features
Very fast-acting
Optional axial leads available
1⁄4" x 1 1⁄4" (6.3 x 32mm) physical size
Ceramic tube, nickel-plated brass endcap
construction
100pc-carton quantity weighs 1.0 lb (0.45 kg)
UL Recognized product meets standard 248-14
Rated Current
1 - 20A
25, 30A
Electrical Characteristics
% of Amp Rating
Opening Time
100%
None
150%
2 minutes maximum
250%
1 seconds maximum
400%
-
100%
None
150%
2 minutes maximum
250%
6 seconds maximum
400%
-
Part Number
GBB-1-R
GBB-1-1/4-R
GBB-2-R
GBB-3-R
GBB-4-R
GBB-5-R
GBB-6-R
GBB-7-R
GBB-8-R
GBB-9-R
GBB-10-R
GBB-12-R
GBB-15-R
GBB-20-R
GBB-25-R
GBB-30-R
Voltage
Rating
Vac
Vdc
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
AC Interrupting
Rating (amps)*
250Vac
125Vac
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
200
200
200
200
200
Speci cations
DC Interrupting
Rating (amps)*
125Vdc
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
200
200
200
Typical DC Cold
Resistance
(Ω)**
0.17750
0.17900
0.06620
0.04475
0.03175
0.02125
0.01800
0.01550
0.01360
0.01070
0.00934
0.00620
0.00472
0.00330
0.00252
0.00206
Typical
Voltage
Drop (V)‡
0.2096
0.2497
0.1687
0.1816
0.1778
0.1217
0.1324
0.1355
0.1144
0.1218
0.0877
0.0806
0.0735
0.0728
0.0610
0.0657
* Interrupting ratings: Interrupting ratings for 1-15A at 125Vdc was measured at 10,000A, 3.5 ms maximum, with time constant. Ratings 20-30A at 125Vdc were measured at 200A, 0.5
ms maximum, with time constant. Ratings 1-15A at 125Vac were measured at 10,000A, and 70% - 80% power factor. The interrupting ratings for 1-30A at 250Vac were measured at
90% - 100% power factor.
** DC Cold Resistance (Measured at <10% of rated current)
† Typical Melting I
2
t (I
2
t was measured at listed interrupting rating and rated voltage) Interrupting ratings were measured at 70% to 80% power factor on AC.
‡ Typical Voltage drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
I don't promote you because you just want to do your job well.
In today's workplace, brave generals charge and kill enemies in business departments, important officials guard the headquarters of the Beijing Urban Management Group, eunuchs operate financial manpow...
苏莎莎 Talking
Super PCB wiring design experience with schematics 1-6 chapters
In today's competitive battery-powered market, designers often use double-sided boards due to cost constraints. Although multi-layer boards (4-, 6-, and 8-layer) have obvious advantages in size, noise...
qin552011373 ADI Reference Circuit
Shanghai Hangxin ACM32F070 Development Board + Touch Function Evaluation Board Evaluation - Chapter 6 CAN Error Handling
This evaluation experiment tests the CAN module communication error handling mechanism.The CAN general specification stipulates that each CAN controller has a send error counter and a receive error co...
oxygen_sh Domestic Chip Exchange
Born only for uC, uS's growth process 3
After deciding to continue using the function callback mechanism to implement the communication method between uSer and Apper, we have to do one very important thing before continuing to implement it....
辛昕 Programming Basics
Has anyone encountered Ubuntu 20.04's suspended animation?
The system was originally intended to run on arm, but it has not been developed yet. Now I have installed Ubuntu on the PC and run it with peripherals, but Ubuntu20.04 will freeze every 2 or 3 days, a...
freebsder Embedded System
Apple HP
...
天天谈芯 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 798  1748  2275  407  2023  17  36  46  9  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号