X: Tape and reel packing (picked from 1/2/3/4 pin side)
Z: Tape and reel packing (picked from 5/6/7/8 pin side)
0
–1–
ASCTB7E 201407-T
GQ (AGQ)
TYPES
1. Standard PC board terminal
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
Single side stable
Part No.
AGQ2001H
AGQ20003
AGQ2004H
AGQ20006
AGQ20009
AGQ20012
AGQ20024
1 coil latching
Part No.
AGQ2101H
AGQ21003
AGQ2104H
AGQ21006
AGQ21009
AGQ21012
AGQ21024
High sensitivity single side stable
Part No.
AGQ2601H
AGQ26003
AGQ2604H
AGQ26006
AGQ26009
AGQ26012
AGQ26024
2. Surface-mount terminal
1) Tube packing
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6
9
12
24
V DC
V DC
V DC
V DC
Single side stable
Part No.
AGQ200 1H
AGQ200 03
AGQ200 4H
AGQ200 06
AGQ200 09
AGQ200 12
AGQ200 24
1 coil latching
Part No.
AGQ210 1H
AGQ210 03
AGQ210 4H
AGQ210 06
AGQ210 09
AGQ210 12
AGQ210 24
High sensitivity single side stable
Part No.
AGQ260 1H
AGQ260 03
AGQ260 4H
AGQ260 06
AGQ260 09
AGQ260 12
AGQ260 24
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Tape and reel packing
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
Single side stable
Part No.
AGQ200 1HZ
AGQ200 03Z
AGQ200 4HZ
AGQ200 06Z
AGQ200 09Z
AGQ200 12Z
AGQ200 24Z
1 coil latching
Part No.
AGQ210 1HZ
AGQ210 03Z
AGQ210 4HZ
AGQ210 06Z
AGQ210 09Z
AGQ210 12Z
AGQ210 24Z
High sensitivity single side stable
Part No.
AGQ260 1HZ
AGQ260 03Z
AGQ260 4HZ
AGQ260 06Z
AGQ260 09Z
AGQ260 12Z
AGQ260 24Z
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tape and reel: 900 pcs.; Case: 1,800 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed.
2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC (resistive load)
60 W (DC), 30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
2A
10μA 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160μs) (FCC Part 68)
2,500 V (2×10μs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 5
×
10
7
(at 180 cpm)
Min. 5
×
10
4
(2 A 30 V DC resistive), Min. 10
5
(1 A 30 V DC resistive),
Min. 10
5
(0.3 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C
–40°F to +185°F
(High sensitivity single side stable type) –40°C to +70°C
–40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g
.035 oz
Rating
Temperature rise (at 20°C
68°F)
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Electrical
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*
2
Max. operating speed (at rated load)
Unit weight
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
1. Max. switching capacity
* Max. switching capacity is 2A 30V DC.
100
No. of operations,
×
10
4
DC resistive load
AC resistive load
4
50
40
30
DC 30V resistive load
20
Pick-up voltage
3
Max.
Min.
2
AC 125V
resistive load
2. Life curve
3. Mechanical life
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 180 cpm
Switching current, A
1.0
0.3
Voltage, V
10
1
Drop-out voltage
Max.
Min.
30
100
Contact voltage, V
0
0.2
0.4
0.6
0.8
1.0
1.2
0
0
10
30
4
50
Switching current, A
No. of operations,
×10
–3–
ASCTB7E 201407-T
GQ (AGQ)
4. Electrical life (1A 30V DC resistive load)
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 20 cpm
5. Coil temperature rise
Change of contact resistance
100
90
Contact resistance, mΩ
80
70
60
50
40
30
20
10
10
5
No. of operations,
×10
4
Change of pick-up and drop-out voltage
Ratio against the rated voltage, %V
100
90
80
70
60
50
40
30
20
10
0
0
5
No. of operations,
×10
4
Tested sample: AGQ200A4H, AGQ200A24, 6 pcs.
Point measured: Inside the coil
Ambient temperature: Room temperature
N.C. contact
N.O. contact
Temperature rise,
°C
70
60
50
40
30
20
1A
0A
4.5V DC type
24V DC type
Pick-up voltage
Max.
Min.
1A
0A
X
X
Drop-out voltage
Max.
Min.
10
0
0
10
0
100
110
120
130
140
150
Coil applied voltage, %
6-(1). Operate and release time (without diode)
Tested sample: AGQ2004H, 10 pcs.
3
Operate and release time, ms
6-(2). Operate and release time (with diode)
Tested sample: AGQ2004H, 10 pcs.
3
Operate and release time, ms
7. Ambient temperature characteristics
Tested sample: AGQ200A4H, 6 pcs.
50
40
30
20
10
x
x
Operate time
Release time
Max.
Operate time
Release time
Max.
2
Min.
2
Min.
Max.
Min.
Drop-out
voltage
-40 -20
0
Rate of change, %V
1
Max.
Min.
1
Pick-up
voltage
20 40
60
80 100
-10
Ambient temperature,
°C
-20
-30
-40
0
70
80
90
100
110
120
130
0
70
80
90
100
110
120
130
-50
Coil applied voltage, %V
Coil applied voltage, %V
8. Malfunctional shock
Tested sample: AGQ200A4H, 6 pcs.
9-(1). Influence of adjacent mounting
Tested sample: AGQ20012, 6 pcs.
Rate of change, %V
10
5
Pick-up voltage
0
-5
-10
10
5
0
-5
-10
0
Drop-out voltage
OFF
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm
inch
ON
OFF
OFF
ON
ON
9-(2). Influence of adjacent mounting
Tested sample: AGQ20012, 6 pcs.
Rate of change, %V
10
5
Pick-up voltage
0
-5
-10
10
5
0
-5
-10
0
Drop-out voltage
OFF
ON
ON
Z X
Z'
Y
Y'
X'
Y
1,000m/s
2
Deenergized condition
Energized condition
X
1,000m/s
2
Z
1,000m/s
2
ON
OFF
1,000m/s
2
Z'
1,000m/s
2
Y'
1,000m/s
2
X'
Rate of change, %V
Rate of change, %V
OFF
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm
inch
DIMENSIONS
(mm
inch)
1. PC board terminal
CAD Data
10.60±0.3
.417±.012
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
5.20±0.2
.205±.008
7.20±0.3
.283±.012
PC board pattern
2.20
.087
3.20
.126
2.20
.087
5.08
.200
0.85 dia.
.033 dia.
Schematic (Bottom view)
Single side stable
High sensitivity
single side stable
1
2 3 4
1 coil latching
1
2 3 4
0.40±0.1
.016±.004
3.20±0.15
.126±.006
2.20±0.15
.087±.006
3.50±0.3
2.20±0.15
.138±.012
.087±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
Tolerance:
±0.1
±.004
8
7 6 5
8
7 6 5
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
–4–
ASCTB7E 201407-T
GQ (AGQ)
2. Surface-mount terminal
CAD Data
Type
External dimensions
Single side stable/1 coil latching/High sensitivity single side stable
10.60±0.3
.417±.012
7.20±0.3
.283±.012
Suggested mounting pad (Tolerance:
±0.1
±.004)
Single side stable/1 coil latching/High sensitivity single side stable
(7) profile_timestamps and PROFILE_TIMESTAMP_PTR are undefined These two variables are in core/sys/profile-aggregates.c, and their purpose is "Compuation of aggregates for the Contiki profiling system...
Relevant research institutions predict that by 2016, the output value of China's medical electronics market will reach 7.4 billion US dollars, with an average annual compound rate of 13%. This is main...
[font=微软雅黑][size=5][b]The live broadcast has ended[/b][/size][/font] [font=微软雅黑][b][color=#ff0000]Live broadcast time: [/color][/b]10:00-11:30 am, December 27, 2017 (today)[/font] [font=微软雅黑][b][color...
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
introduction
MEMS is a high-tech that has flourished on the basis of integrated circuit production technology and dedicated micro-electromechanical processing methods. Pressure sensors develop...[Details]
Problems such as the depletion of natural resources, air pollution, traffic congestion, and rising fossil fuel prices have forced societies and individuals to seek alternative means of transportati...[Details]
Motors, especially those with brushes, generate a lot of noise. This noise must be dealt with if the appliance is to meet the requirements of EMC standards. The means to solve EMC are nothing more ...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
LED is the abbreviation of the English word. Its main meanings are: LED = Light Emitting Diode, a solid-state semiconductor device that can convert electrical energy into visible light. It can dire...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]
The emergence and development of street lamps are inseparable from the prosperity and progress of cities, which makes street lamps useful. Conversely, street lamps also make the night of the city n...[Details]