3.6ADOSJ31.5

Description
Special fuse 3.6KV 31.5AMP 2" AIR
CategoryCircuit protection    The fuse    Special fuse   
File Size82KB,5 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric View All

3.6ADOSJ31.5 Overview

Special fuse 3.6KV 31.5AMP 2" AIR

3.6ADOSJ31.5 Parametric

Parameter NameAttribute value
MakerBussmann (Eaton)
Product CategorySpecial fuse
Shipping restrictionsMouser does not currently sell this product.
RoHSN
seriesADOS
productMedium Voltage Fuses
Current rating31.5 A
Voltage ratingAC3.6 kVAC
Termination typeCartridge (Non Standard)
Indicator typeStriker Pin
EncapsulationBulk
typeFuse Link, Air
Factory packaging quantity1
unit weight1.134 kg
HIGH VOLTAGE DIN DISTRIBUTION
3.6 kV – 36 kV FUSES
DIN Dimension Fuses To Spec. DIN 43.625
This product group covers current limiting fuses with dimen-
sions to DIN 43.625 and performance in compliance with
IEC 282-1.
Advantages of Edison High Voltage Current -
Limiting Fuse
The low power dissipation of Edison fuses ensures low tem-
perature rise of switchgear in which they are incorporated.
The elements use the ‘M’ (metallurgical) effect, similar to
that used in low voltage fuses. This ensures that, with melt-
ing on long time overloads, excessive temperatures are not
reached and damage to switchgear components, such as
epoxy encapsulating enclosures, is thus prevented. Fuses
of Continental European manufacture which in general do
not employ this feature are not only hotter running by com-
parison but also usually need to employ a higher current rat-
ing of fuse for the same service; thus an Edison 40A fuse is
equivalent in terms of thermal performance to many
Continental European types of 63A rating.
Edison fuses exhibit considerable limitation of current and
I
2
t under short circuit conditions. The stress on circuit com-
ponents is thereby minimized and the reduction of energy
release at the fault reduces fire risks.
Switching (arc) voltages are appreciably less than permitted
values and fall with lower values of recovery voltage. The
use of, for example, 12 kV fuse on 6/7.2 kV systems is
therefore permissible.
Striker Characteristics
The spring operated striker pin has a travel and energy out-
put in compliance with the requirements of DIN 43625 and
IEC 282-1.
Travel is approx. 26mm
Energy Output is approx. 0.6 joule
Force/Travel Output Characteristics
60
50
40
FORCE (N)
30
20
10
0
0
5
10
15
TRAVEL (mm)
20
25
30
Current Ratings
These are in accordance with the R10 and, in some cases,
the R20 series of preferred numbers.
131

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1976  1252  1968  2888  1421  40  26  59  29  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号