10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10μs) (Only the NC contact of 1 Form C is 0.82mm)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 1×10
6
(at 180 times/min.)
Ambient temperature: –40 to +85°C
–40 to +185°F
(Class B insulation), –40 to +105°C
–40 to +221°F
(Class F
insulation),
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 11 g
.39 oz
Specifications
Notes: *1.This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of
±1.2×50μs
according to JEC-212-1981
*3. For the ambient temperature, please refer to Usage, transport and storage conditions in NOTES.
*Please note that some of the specifications listed above may not comply with overseas standards.
3. Expected electrical life
Condition: Resistive, at 20°C
68°F
Type
1 Form A
NO contact
1 Form C
NC contact
For the operating ambient temperature, please read the notes
16A 250V AC
Switching capacity
16A 250V AC
16A 250V AC
Number of operations
Min. 1×10
5
(ON:OFF = 1.5s:1.5s)
Min. 5×10
4
(ON:OFF = 1.5s:1.5s)
Min. 1×10
4
(ON:OFF = 1.5s:1.5s)
–2–
ASCTB395E 201809-T
LZ-N (ALZN)
REFERENCE DATA
1. Max. switching capacity (AC resistive load)
2. Coil temperature rise (Ave.)
Tested sample: ALZN1F12, 6pcs.
Contact current: 16A
Ambient temperature: Normal temperature • 85°C
185°F
• 105°C
221°F
Measured portion: inside the coil
100
50
30
20
10
5
65
Normal temperature 16A
Coil applied voltage, %V
60
Temperature rise,
°C
55
50
45
40
35
30
50
25
0
30
100
500 1,000
Contact voltage, V
20
95 100 105 110 115 120 125 130 135
Coil applied voltage, %V
0
0
85°C 16A
105°C 16A
3. Ambient temperature characteristics (Ave.)
Tested sample: ALZN1F12, 6pcs.
Contact carrying current: 0A, 16A
Measured portion: inside the coil
300
250
16A 155°C
Contact current, A
200
150
100
16A 130°C
Operate voltage
(Hot start: 16A, 100%V)
1
0.5
Operate voltage
(Cold start: Coil and contact no carrying current)
20
40
60
80
100
Ambient temperature,
°C
120
DIMENSIONS
(mm
inch)
1. 1 Form A type
The CAD data of the products with a “CAD” mark can be downloaded from our Website.