Z: Tape and reel packing (Picked from the 8/9/10/12-pin side)
Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
TYPES
1. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V
TXD2-3V
TXD2-4.5V
TXD2-5V
TXD2-6V
TXD2-9V
TXD2-12V
TXD2-24V
1 coil latching
Part No.
TXD2-L-1.5V
TXD2-L-3V
TXD2-L-4.5V
TXD2-L-5V
TXD2-L-6V
TXD2-L-9V
TXD2-L-12V
TXD2-L-24V
2 Form C
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V
TXD2S -3V
TXD2S -4.5V
TXD2S -5V
TXD2S -6V
TXD2S -9V
TXD2S -12V
TXD2S -24V
1 coil latching
Part No.
TXD2S -L-1.5V
TXD2S -L-3V
TXD2S -L-4.5V
TXD2S -L-5V
TXD2S -L-6V
TXD2S -L-9V
TXD2S -L-12V
TXD2S -L-24V
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
ASCTB19E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TX-D
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-Z
TXD2S -3V-Z
TXD2S -4.5V-Z
TXD2S -5V-Z
TXD2S -6V-Z
TXD2S -9V-Z
TXD2S -12V-Z
TXD2S -24V-Z
1 coil latching
Part No.
TXD2S -L-1.5V-Z
TXD2S -L-3V-Z
TXD2S -L-4.5V-Z
TXD2S -L-5V-Z
TXD2S -L-6V-Z
TXD2S -L-9V-Z
TXD2S -L-12V-Z
TXD2S -L-24V-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-1” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-1-Z)
2. M.B.B type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open contacts)
1,000 V
1) Standard PC board terminal
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Single side stable
Part No.
TXD2-2M-1.5V
TXD2-2M-3V
TXD2-2M-4.5V
TXD2-2M-5V
TXD2-2M-6V
TXD2-2M-9V
TXD2-2M-12V
TXD2-2M-24V
2 Form C
2) Surface-mount terminal
(1) Tube packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -2M-1.5V
TXD2S -2M-3V
TXD2S -2M-4.5V
TXD2S -2M-5V
TXD2S -2M-6V
TXD2S -2M-9V
TXD2S -2M-12V
TXD2S -2M-24V
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
(2) Tape and reel packing
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -2M-1.5V-Z
TXD2S -2M-3V-Z
TXD2S -2M-4.5V-Z
TXD2S -2M-5V-Z
TXD2S -2M-6V-Z
TXD2S -2M-9V-Z
TXD2S -2M-12V-Z
TXD2S -2M-24V-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Types designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.
However, please contact us if you need parts for use in low level load. (Ex. TXD2SA-2M-1.5V-1-Z)
2. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB19E 201209-T
TX-D
3. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V-6
TXD2-3V-6
TXD2-4.5V-6
TXD2-5V-6
TXD2-6V-6
TXD2-9V-6
TXD2-12V-6
TXD2-24V-6
1 coil latching
Part No.
TXD2-L-1.5V-6
TXD2-L-3V-6
TXD2-L-4.5V-6
TXD2-L-5V-6
TXD2-L-6V-6
TXD2-L-9V-6
TXD2-L-12V-6
TXD2-L-24V-6
2 Form C
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
2 Form C
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-6
TXD2S -3V-6
TXD2S -4.5V-6
TXD2S -5V-6
TXD2S -6V-6
TXD2S -9V-6
TXD2S -12V-6
TXD2S -24V-6
1 coil latching
Part No.
TXD2S -L-1.5V-6
TXD2S -L-3V-6
TXD2S -L-4.5V-6
TXD2S -L-5V-6
TXD2S -L-6V-6
TXD2S -L-9V-6
TXD2S -L-12V-6
TXD2S -L-24V-6
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-6-Z
TXD2S -3V-6-Z
TXD2S -4.5V-6-Z
TXD2S -5V-6-Z
TXD2S -6V-6-Z
TXD2S -9V-6-Z
TXD2S -12V-6-Z
TXD2S -24V-6-Z
1 coil latching
Part No.
TXD2S -L-1.5V-6-Z
TXD2S -L-3V-6-Z
TXD2S -L-4.5V-6-Z
TXD2S -L-5V-6-Z
TXD2S -L-6V-6-Z
TXD2S -L-9V-6-Z
TXD2S -L-12V-6-Z
TXD2S -L-24V-6-Z
2 Form C
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-7” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-7-Z)
ASCTB19E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TX-D
4. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,500 V (High breakdown voltage type)
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2-1.5V-3
TXD2-3V-3
TXD2-4.5V-3
TXD2-5V-3
TXD2-6V-3
TXD2-9V-3
TXD2-12V-3
TXD2-24V-3
1 coil latching
Part No.
TXD2-L-1.5V-3
TXD2-L-3V-3
TXD2-L-4.5V-3
TXD2-L-5V-3
TXD2-L-6V-3
TXD2-L-9V-3
TXD2-L-12V-3
TXD2-L-24V-3
2 Form C
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
2 Form C
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2S -1.5V-3
TXD2S -3V-3
TXD2S -4.5V-3
TXD2S -5V-3
TXD2S -6V-3
TXD2S -9V-3
TXD2S -12V-3
TXD2S -24V-3
1 coil latching
Part No.
TXD2S -L-1.5V-3
TXD2S -L-3V-3
TXD2S -L-4.5V-3
TXD2S -L-5V-3
TXD2S -L-6V-3
TXD2S -L-9V-3
TXD2S -L-12V-3
TXD2S -L-24V-3
: For each surface-mount terminal identification, input the ollowing letter. SA type: A, SS type: S
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TXD2SA-1.5V-3-Z
TXD2SA-3V-3-Z
TXD2SA-4.5V-3-Z
TXD2SA-5V-3-Z
TXD2SA-6V-3-Z
TXD2SA-9V-3-Z
TXD2SA-12V-3-Z
TXD2SA-24V-3-Z
1 coil latching
Part No.
TXD2SA-L-1.5V-3-Z
TXD2SA-L-3V-3-Z
TXD2SA-L-4.5V-3-Z
TXD2SA-L-5V-3-Z
TXD2SA-L-6V-3-Z
TXD2SA-L-9V-3-Z
TXD2SA-L-12V-3-Z
TXD2SA-L-24V-3-Z
2 Form C
*Only for SA type.
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-4” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-4-Z)
I am a beginner, and I am learning to use the 2812 development board to write a spwm output program. However, after changing CMPR1, the output waveform has no response, and the PWM1 pin still has puls...
[size=4]When making high-frequency power supplies, sampling of high-frequency AC signals is often involved. The traditional sampling circuit is as follows: [/size] [size=4] [/size] [align=center][size...
I found that friends in the forum don’t like to write blogs very much. It seems that they don’t pay much attention to the recommended blogs under each topic. Can you name a friend who writes blogs eve...
I need to play videos under WINCE, and I need to be able to play AVI and other files (video supports MEPG1\2\4, Divx, xVid formats, audio supports MP3, WAV, WAV). I don't know much about video playbac...
When talking about Chinese chips, Ni Guangnan is indispensable. Let’s learn more about the relevant content with the embedded editor.
Since he co-founded Lenovo in 1985, Ni Guangnan has been s...[Details]
Profit growth of 85% in 2017, target revenue of 12.5 billion yuan in 2018: The company released its 2017 annual report, achieving revenue of 8.886 billion yuan, a year-on-year increase of 48.01%; prof...[Details]
I recently upgraded MDK to V5.25 and found that there are many libraries in the Managing Run-Time Environment. Compared with the past, it is much better, from the bottom-level driver to the upper-le...[Details]
Security PPP is a new model of urban video surveillance projects: 1) The government and social capital establish a project company in a certain proportion; 2) The project company participates in the ...[Details]
Overview
Lightning is a strong discharge phenomenon that occurs between thunderstorm clouds and between thunderstorm clouds and the earth due to severe convective weather. Lightning is gen...[Details]
ZTE was punished, and Hou Weigui, who had already retired, had to come out of retirement again and run around to mediate. Let's follow the embedded editor to learn about the relevant content.
...[Details]
At present, the Beidou system has achieved industrial breakthroughs and leapfrog development in five major areas, including the automotive OEM market, smart phones, and high-precision applications....[Details]
This program uses the eight-channel ADC single acquisition mode. According to the configuration, ADC12SC will automatically reset after the conversion is completed in the single mode, so it is necess...[Details]
In recent years, in order to meet the needs of social development, more and more companies have entered the fields of smart phones, artificial intelligence,
VR
, AR, etc. After seeing the d...[Details]
On May 8,
Google
I/O 2018 Developer Conference was held as scheduled in Mountain View, California. In the second year of the full promotion of the "AI first" strategy, artificial intelligen...[Details]
STM32 has 2 watchdogs: independent watchdog and window watchdog. Independent watchdog IWDG: A system fault detector that is independent of the system and is not affected by the system because it has ...[Details]
The calculation formula of the watchdog feeding time (watchdog overflow time) is: Tout=((4*2^prer)*rlr)/40 Tout is the watchdog overflow time (in ms), prer is the watchdog clock prescaler value (...[Details]
The photovoltaic industry has become a new business card for China to the world. It not only represents China's leading technology, but also constantly breaks various records with its development spee...[Details]
I encountered a problem when debugging the STM32 system clock setting: TIM2 timing 1Ms, TIM2 interrupt service function time++, LED state changes when time=100. After the program runs, I found that t...[Details]
The STM8L contains a 12-bit ADC with 25 input channels, including an internal temperature sensor, an internal reference voltage As can be seen from the figure above, there is an internal re...[Details]