Parameter NameAttribute value
MakerVICOR
Product Categoryswitching power supply
seriesFlatPAC
FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95V
DC
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40ms ride-through time
OVP and thermal shutdown
1 output; up to 200W
1 or 2 outputs; up to 400W
Configuration Chart
Typical Model: VI-RU
0 1 1
-
E U U U
-
Input
115/230 Vac
A
Output
F F A
1:
5 V
DC
at 200W
2:
12 V
DC
at 200W
3:
12 V
DC
at 200W
Input Characteristics
90–132/180–264 Vac
U
= Autoranging
Configuration
Single Output
Substitute VE– for VI– for RoHS compliant versions
Total
# of
Power
Converters
Dimensions
VI-LU
VI-MU
VI-NU
F
F
F
F
F
F
-
-
-
A
A
A
A
F
A
A
50 – 200W
200 – 400W
F
A
A
1
2
3
300 – 600W
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Dual Output
VI-PU
VI-QU
-
-
100 – 400W
150 – 600W
F
A
2
3
1, 2, or 3 outputs; up to 600W
Product Highlights
If y
ou’re looking for the convenience
of a complete, low profile, agency-approved
switching power supply, look no further. The
FlatPAC combines Vicor’s workhorse VI-200
family of DC-DC converters with a modular
package and front-end subassembly to provide
from 50 to 600W of output power from one to
three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the
model number.
F A
F FA FA A
F A
F
Triple Output
VI-RU
F A
A
F FA A
-
150 – 600W
A
3
Output Voltage
A F A A
F F FA F A F
Z
= 2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
A
F
0
= 5V
Y
= 3.3V
X
= 5.2V
Product Grade Temps. °C
Grade
Operating
Storage
E
=
0 to +85
–20 to +100
F
0 to +85
–20 to +100
I
=
–30 to +85
–55 to +100
Temperatures apply to product case.
Output Power/Current
V
OUT
≥5V
V
OUT
< 5V
Y
X
W
V
U
=
=
=
=
=
10A
15A
20A
30A
40A
Y
X
W
V
U
=
=
=
=
=
50W
75W
100W
150W
200W
Vicor’s FlatPAC is also available with a current
controlled output using BatMod converter
modules of 12, 24, or 48V
DC
outputs. This option
is specified by appending “BM” or “BC” (for
conduction cooled versions) to the end of the
FlatPAC model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
F
A
C
=
A
Output Power/Current
F
V
A
OUT
≥5V
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a
complete power solution, enabling you to spend
more time designing your system and less time
worrying about how to power it.
F A
W
= 100W
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
Output Power/Current
F
A
V
OUT
≥5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
Options
BC
= BatMod/Conduction Cooled
BM
= BatMod
CC
= Conduction Cooled
FlatPAC™
Page 1 of 6
Rev 1.7
09/2016
vicorpower.com
800 927.9474
Problems with hooks in wince
I read a lot of information and found that WinCE only supports three types of hooks. I loaded coredll.dll according to the information and debugged it on the simulator. After installing it with WH_KEY...
luoyaxu Embedded System
RS485 bus communication stability
[size=3]To analyze and diagnose communication failures, it is necessary to understand some basic concepts of RS485 bus. [/size] [size=3][/size] [size=3]1. Basic characteristics of RS485 bus [/size] [s...
qwqwqw2088 Analogue and Mixed Signal
RSL-10 development environment construction
[i=s]This post was last edited by Purple Sky on 2021-5-17 14:03[/i]Link to ON Semiconductor's official IDE: Link: https://pan.baidu.com/s/1HihO1gceWMOixCnYgR8aGg Extraction code: 0btw The installation...
紫色的天空 onsemi and Avnet IoT Innovation Design Competition
I have a measurement board and want to use batteries to power it. Considering the working time problem, I plan to connect batteries in parallel to power it. I would like to ask the experts for help...
There is a measurement board with few devices on it. The only power consumption is wireless transmission and sensors, plus a CPU and several amplifiers. The maximum working current is below 100mA, but...
longhui520 Power technology
STM32 RTC
I want to use the query method to determine whether the RTC has generated a second carry. Why is SECF always 1 when I query it? What are the requirements for clearing it? Thank you very much! Use LSE ...
gzzhang stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2050  1287  2806  378  1043  42  26  57  8  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号