EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-PULF-EUY

Description
Switching power supply VI-PULF-EUY
CategoryPower/power management    Switching power supply   
File Size755KB,7 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-PULF-EUY Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-PULF-EUY - - View Buy Now

VI-PULF-EUY Overview

Switching power supply VI-PULF-EUY

VI-PULF-EUY Parametric

Parameter NameAttribute value
MakerVICOR
Product Categoryswitching power supply
seriesFlatPAC
FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95V
DC
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40ms ride-through time
OVP and thermal shutdown
1 output; up to 200W
1 or 2 outputs; up to 400W
Configuration Chart
Typical Model: VI-RU
0 1 1
-
E U U U
-
Input
115/230 Vac
A
Output
F F A
1:
5 V
DC
at 200W
2:
12 V
DC
at 200W
3:
12 V
DC
at 200W
Input Characteristics
90–132/180–264 Vac
U
= Autoranging
Configuration
Single Output
Substitute VE– for VI– for RoHS compliant versions
Total
# of
Power
Converters
Dimensions
VI-LU
VI-MU
VI-NU
F
F
F
F
F
F
-
-
-
A
A
A
A
F
A
A
50 – 200W
200 – 400W
F
A
A
1
2
3
300 – 600W
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Dual Output
VI-PU
VI-QU
-
-
100 – 400W
150 – 600W
F
A
2
3
1, 2, or 3 outputs; up to 600W
Product Highlights
If y
ou’re looking for the convenience
of a complete, low profile, agency-approved
switching power supply, look no further. The
FlatPAC combines Vicor’s workhorse VI-200
family of DC-DC converters with a modular
package and front-end subassembly to provide
from 50 to 600W of output power from one to
three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the
model number.
F A
F FA FA A
F A
F
Triple Output
VI-RU
F A
A
F FA A
-
150 – 600W
A
3
Output Voltage
A F A A
F F FA F A F
Z
= 2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
A
F
0
= 5V
Y
= 3.3V
X
= 5.2V
Product Grade Temps. °C
Grade
Operating
Storage
E
=
0 to +85
–20 to +100
F
0 to +85
–20 to +100
I
=
–30 to +85
–55 to +100
Temperatures apply to product case.
Output Power/Current
V
OUT
≥5V
V
OUT
< 5V
Y
X
W
V
U
=
=
=
=
=
10A
15A
20A
30A
40A
Y
X
W
V
U
=
=
=
=
=
50W
75W
100W
150W
200W
Vicor’s FlatPAC is also available with a current
controlled output using BatMod converter
modules of 12, 24, or 48V
DC
outputs. This option
is specified by appending “BM” or “BC” (for
conduction cooled versions) to the end of the
FlatPAC model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
F
A
C
=
A
Output Power/Current
F
V
A
OUT
≥5V
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a
complete power solution, enabling you to spend
more time designing your system and less time
worrying about how to power it.
F A
W
= 100W
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
Output Power/Current
F
A
V
OUT
≥5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
Options
BC
= BatMod/Conduction Cooled
BM
= BatMod
CC
= Conduction Cooled
FlatPAC™
Page 1 of 6
Rev 1.7
09/2016
vicorpower.com
800 927.9474
Ask experts to help analyze the output current control circuit
Let me explain the purpose. Input AC power from J3 and control the on/off of the MOS tube to control the current at output. Is there any problem with this design? Also, what are the functions of R13 a...
cat3902982 Analog electronics
Buck Regulator PDF Document (Full Version)
...
blink Analogue and Mixed Signal
I allow you to enter my world, but I don't allow you to walk around in my world.
I allow you to enter my world, but I don't allow you to walk around in my world.. 1. Be good to yourself, because life is short; be good to the people around you, because you may not meet them in the ...
沙漠里的水 Talking
In AD, if the circle on the surface of the circuit board is not painted with green paint, should a solid circle or a ring be drawn on the TOPSOLDER layer?
In AD, if you want to avoid green paint inside the circle on the top surface of the circuit board, should you draw a solid circle or a ring on the TOPSOLDER layer? As shown in the figure below...
一沙一世 stm32/stm8
[Technical Post] How to interview for an engineering position
[align=left]While browsing Tianya, I saw someone post an article about how engineers interview. It was written quite well and covered all aspects, including career planning, resume writing, face-to-fa...
xiaoniaoniao Talking about work
How can I get my program to respond to the interrupt request generated by the timer?
How can I get the interrupt request generated by the timer to respond to my own program? I want to use the timer to execute a program I wrote when the specified time arrives. How can I get the timer's...
nicoyu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2300  2119  1071  383  2598  47  43  22  8  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号